PLANET Technology does not warrant that the hardware will work properly in all environments and applications, and
makes no warranty and representation, either implied or expressed, with respect to the quality, performance,
merchantability, or fitness for a particular purpose.
PLANET has made every effort to ensure that this User's Manual is accurate; PLANET disclaims liability for any
inaccuracies or omissions that may have occurred.
Information in this User's Manual is subject to change without notice and does not represent a commitment on the part of
PLANET. PLANET assumes no responsibility for any inaccuracies that may be contained in this User's Manual. PLANET
makes no commitment to update or keep current the information in this User's Manual, and reserves the right to make
improvements to this User's Manual and/or to the products described in this User's Manual, at any time without notice.
If you find information in this manual that is incorrect, misleading, or incomplete, we would appreciate your comments and
suggestions.
FCC Warning
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the
FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is
operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not
installed and used in accordance with the Instruction manual, may cause harmful interference to radio communications .
Operation of this equipment in a residential area is likely to caus e harmful interference in which case the user will be
required to correct the interference at whose own expense.
CE Mark Warning
This is a Class A product. In a domestic environment, this product may cause radio interference, in which case the user
may be required to take adequate measures.
WEEE Warning
To avoid the potential effects on the environment and human health as a result of the presenc e of
hazardous substances in electrical and electronic equipment, end users of electrical and electronic
equipment should understand the meaning of the crossed-out wheeled bin symbol. Do not dispose of
WEEE as unsorted municipal waste and have to collect such WEEE separately.
Revision
PLANET RS-232/RS-422/RS-485 over 10/100Base-TX/100Base-FX Media Converter User's Manual
FOR MODELS: ICS-100 / ICS-102 / ICS-102S15
REVISION: 1.1 (APRIL.2008)
Part No.: 2080-AA3600-000
1.5PRODUCT FEATURES .................................................................................................................................. 4
2.1.2 LED Indicators.....................................................................................................................................................9
3.3.1 Web Management.............................................................................................................................................14
3.3.2 Login the Media converter.................................................................................................................................14
4. WEB CONFIGURATION...............................................................................................16
4.2.1 System Information...........................................................................................................................................17
4.2.5 System Reboot..................................................................................................................................................21
4.4.1 TCP server mode..............................................................................................................................................23
4.4.4 Virtual COM mode.............................................................................................................................................31
4.4.5 Telnet Server mode...........................................................................................................................................37
4.4.6 Pair Connection– Local mode...........................................................................................................................42
5.1INSTALLING THE VCOMUTILITY ................................................................................................................ 49
5.2SEARCH THE DEVICE................................................................................................................................. 51
Thank you for purchasing PLANET Serial over Fast Ethernet Media Converter – ICS-10x series. Terms of “Serial Media
Converter” means the products mentioned titled in the cover page of this User’s manual
1.1 Package Contents
Open the box of the Serial Media Converter and carefully unpack it. The box should contain the following items:
Check the contents of your package for following parts:
Serial Media Converter x1
CD-ROM user's manual x1
Quick installation guide x1
External 5VDC / 2.5 A pow er adapter x 1
If any of these are missing or damaged , please contact your dealer i mmediately, if po ssible, retain the carton including the
original packing material, and use them against to repack the product in case there is a need to return it to us for repair.
1.2 How to Use This Manual
This Media Convert e r Us er Man u al i s st r uc tu r ed as fo l lows:
Section 2, Installation
It explains the functions of ICS-10x and how to physically install the ICS-10x.
Section 3, Management
The chapter explains how to manage the converter by Web interface.
Section 4, Web Configuration
It contains information about the Smart function of ICS-10x.
Section 5, So ftware VCOM Utility
It explains the software VCOM how to use with the operation Virtual COM.
Appendices
It contains cable information of ICS-10x.
-1-
User’s Manual of ICS-10x
1.3 Product Description
The Web-Smart ICS-10x series Media Converter / Device Server provide to converts Serial RS-232 / RS-422 / RS-485
communication interface over Fast Ethernet networking. There are RJ-45/SC connectors and
single-mode/multi-mode media for your needs. Ethernet signal that allows two types of segments to connect easily,
efficiently and inexpensively. This converter can be used as a stand-alone unit or as a slide-in module to the PLANET
Media Converter Chassis (MC-700, MC-1000 and MC-1500). It’s time saving expense for user and SI, no need to
replace the existing Serial equipment and software system.
It extends the distance of deploying Serial equipments and hosts. The selectable fiber-Optic wires on the basis of
distance are flexibly provided. Therefore, this product will perfectly satisfy the di verse demands while providing reliable
and efficient network solutions based on the distance and budgets of installation.
The ICS-10x make connected Serial equipment becomes IP-based. That also makes them be able to connect to a
TCP/IP networking immediately. Each Web-Smart converter is able to manage through the Web Interface. The powerful
Web-Smart Media Converter supports Application mode, Serial operation mode connect alarm and IP address, etc.
Management function helps reduce the amount of valuable time that a network administrator spends detecting and
locating network problems, otherwise it requires visual inspection of cabling and equipment. Multiple connection op tions
for large networking environment are available as well.
1.4 Applications
Access Control System – traditional installation
Most of the enterprise and government use access control plate a n d Mifare or RFID to authorize the entrance identity.
With traditional deploy, access control machine use RS-232 or R S-485 serial inte rface and cabl es connect to login server.
With connection to ICS-10x Serial over Fast Ethernet Converter, the access control machine is able to be extend over
longer distances via fiber optical interface. The distance can be up to 20 km in a local ra nge. Or the ICS-10x can be lin ked
to a xDSL router to get the internet access capability; the access control can be set and monitored over the internet.
Figure 1-1 Serial Converter for Access Control System application
-2-
User’s Manual of ICS-10x
Process Control
To monitor, configure and manage the Robot conveyer including other machines in a manufactu ring, PLC (Programmable
Logical Control) is required. The PLC is used to drive above the manufacturing machines process. The ICS-10x can be se t
to TCP Server mode and connect the PLC. The administrator can configure and set command settings through Fast
Ethernet intranet to control the PLC , the administra tor and w orkstation . There i s no need to be alway s sets by the side of
the I/O machine.
Figure 1-2 Serial Converter for factory PLC application
RTU Data Collect – UDP Mode
Connect with RTU (Remote Terminal Unit) to collect and monitor the data of waves, sig nal and pow er utilizati on. ICS-10x
can be used to set-up UDP mode and send data over Fast Ethernet to Local server or over internet to remote server
automatically.
Figure 1-3 Serial Converter for factory RTU application
-3-
User’s Manual of ICS-10x
Surveillance motion control – Pair Connection Mode
Using pair connection along with fiber optical patch cord, the ICS-10x extend RS-232/RS-485 interfaces distance from
surveillance and scanner to the control keyboard/joystick which is installed in the remote monitor center.
Figure 1-4 Serial Converter for distance extend application
1.5 Product Features
Serial Interface
One RS-232/422/485 port to one 10/100Base-TX or 100Base-FX Media Converter
Cost effective solution for RS-232 to Ethernet application
Supports RS-232, 4-wire RS-422 or 2/4-wire RS485 operation
Asynchronous serial data rates up to 921600b/s
Ethernet Interface
Complies with IEEE 802.3, IEEE 802.3u 10/100Base-TX, 100Base-FX standard
Supports auto MDI/MDI-X function on RJ-45 Port
Choice of fiber-connector from SC, multi-mode / single-mode fiber
Smart Functions
Standard TCP/IP interface and versatile operation modes
Software Protocol Support ARP, ICMP,TCP/IP, UDP, HTTP server, DHCP client, Telnet server/client
Built-in IP-Base Web interface for remote management
Serial Operation mode selected via Web management
Pair Connection mode for connecting two serial devices over a network
PLANET Smart Discovery utility automatically finds xxx devices on the network
Firmware upgrade via HTTP protocol
Hardware
Compact size for easy Installation:
¾ Standalone - Wall mountable or DIN-Rail mounting (Optional accessory)
-4-
¾ Co-work with PLANET MC family Media Chassis ( MC-700/1000R/1500)
LED indicators for easy network diagnose
Reset Button at the front panel for reset to factory default
1.6 PRODUCT SPECIFICAT ION
Products ICS-100 ICS-102 ICS-102S15
Hardware Specification
Interface RS-232 / RS-422 / RS-485
Connector 3-in-1 DB9
Baud rate 110 to 921600bps
Character Bits 5,6,7,8
User’s Manual of ICS-10x
Serial Port
Ethernet Port
Cable Twisted-pair
Protection Built-in 1.5KV magnetic isolation
LED Indicators
Management
Operation Mode
Parity type 1,2
Stop Bit None, Even, Odd
Flow Control None, RTS/CTS, Xon/Xoff
System: Power
TP or Fiber Port: Link / Active
Serial Port: Link / Active
Web Management
PLANET VCOM Utility
PLANET Smart Discovery Utility
TCP Server
TCP Client
UDP Client
Virtual COM
Telnet Server
Pair Connection – Remote (Slave)
Pair Connection – Local (Master)
9/125μm single-mode
cable
-5-
User’s Manual of ICS-10x
Dimension (W x D x H) 97 x 70 x 26mm
Weight 200g
Power Supply External Power Adaptor 5V DC / 2A max.
Power Consumption 5.5 Watts (maximum)
Mechanical Metal
Operating Temperature: 0~50 Degree C
Environment
Emissions FCC Class A, CE Certification Class A
Standards
Regulatory Approval
Compatible Media Converter
Chassis
Note. Reset Button at the rear panel for reset to factory default
Storage Temperat ur e: - 1 0~ 7 0 D egr e e C
Humidity: 10%~90% RH (operating)
This section describes the hardware features and installation of the ICS-10X’s components on the desktop or shelf. For
easier management and control of the ICS-10x, familiarize yourself with its display indicators, and ports. Front panel
illustrations in this chapter display the unit LED indicators. Before connecting any network device to the Serial Media
Converter, please read this chapter completely.
2.1 Hardware Description
2.1.1 Product Layout
Figure 2-1 to Figure 2-4 show layout and front panel of ICS-10X.
ICS-100 – RS-232 / RS-422 / RS-485 over 10/100Base-TX
PWR Green Lights to indicate that the Converter is powered on.
To indicate that the Fast Ethernet Port is successfully connecting to
the network at 10Mbps or 100Mbps
To indicate the Fast Ethernet Port is receiving or sending data
To indicate that the UART Port is connected successfully
To indicate the UART Port is receiving or sending data
TP or Fiber Green
Serial Green
Lights
Blinks
Lights
Blinks
2.1.3 DB9 Pin Define
DB9 Pin Define for RS-232 / RS-422 / RS-485
User’s Manual of ICS-10x
DB9-PIN RS-232
1 DCD
2 RXD
3 TXD
4 DTR RX- Data B(-)
5 GND
6 DSR TX-
7 RTS RX+ Data A(+)
8 CTS TX+
9 RI
RS-422/485
4-wire
RS-485
2-wire
2.1.4 ICS-10X Rear Panel
The rear panel of the converter indicates one DC jack, which accepts input power with 5V DC 2.5A.
■ ICS-10x series
Figure 2-5 Rear Panel of ICS-10x
1. The device is a power-required device, it means, it will not work till it is powered. If your
networks should active all the time, please consider using UPS (Unin terrupted Pow er Supply )
Power
Notice:
for your device. It will prevent you from network data loss or network downtime.
2. In some area, installing a surge suppression device may also help to protect your Media
Converter from being damaged by unregulated surge or current to the converter or the power
adapter.
-9-
User’s Manual of ICS-10x
To press and release the RESET button. The ICS-10X will back to the fa ctory default mode. Be sure that
you backup the current configuration of ICS-10X; else the entire configuration will be erased when
pressing the “RESET” button.
• Press and release the RESET button shortly, the device will be rebooted.
• Press the RESET button more than 10 seconds, the device will back to the factory default
mode; the entire configuration will be erased.
2.2 Install the Converter
This section describes how to install your ICS-10X Web Smart Media Converter and make connections to the converter.
Please read the following topics and perform the procedures in the order being presented. The hardware installation of
PLANET ICS-10X Web Smart Media Converter do n ot need software configuration. To install your ICS-10X on a de sktop
or shelf, simply complete the following steps.
2.2.1 Stand-alone Installation
To install an ICS-10X stand-alone, on a desktop or shelf, simply complete the following steps:
Step 1: Turn off the power of the device/station in a network to which the ICS-10X will be attached.
Step 2: Ensure that there is no activity in the network.
Step 3: Attach RJ-45 / SC Fiber cable from the ICS-10X to the network.
Step 4: Attach RS-232/RS-485 cable from the ICS-10X to the want to connect devices.
Step 5: Connect the 5VDC power adapter to the ICS-10X and verify that the Power LED lights up.
Step 6: Turn on the power of the device/station; the PWR LED (Green) should light when all cables are attached.
Figure 2-6 ICS-100 stand alone installation
-10-
User’s Manual of ICS-10x
Figure 2-7 ICS-102 / ICS-102S15 stand alone installation
Please refers to APPENDIX-A for detailed wiring information of the ICS-10X.
To prevent from optic acceptor malfunction, check the both wires / transmitter before power on the
converter.
2.2.2 Chassis Installation and Rack Mounting
To install the Media Converter in a 10-inch or 19-inch with standard rack, follow the instructions described below.
Step 1: Place your ICS-10X on a hard flat surface, with the front panel positioned towards your front side.
Step 2: Carefully slide in the module until it is fully and firmly fitted into the slot of the chassis.
Figure 2-8 Insert a Media Converter into an availabl e sl ot
Step 3: Attach a rack-mount bracket to each side of the Chassis with supplied screws attached to the package.
-11-
User’s Manual of ICS-10x
Step 4: After the brackets are attached to the chassis, use suitable screws to securely attach the brackets to the rack, as
shown in Figure 2-2.
Step 5: Precede with the steps 4 and steps 5 of session 2.2.1 Stand-alone Inst al lation to connect the network cabling
and supply power to your converter.
You must use the screws supplie d with the mounting brackets. Damage caused to the parts by using
incorrect screws would invalidate your warranty.
Figure 2-9 Mounting the Chassis in a Rack
-12-
User’s Manual of ICS-10x
3. MANAGEMENT
This chapter describes how to manage the ICS-10X. Topics include:
- Overview
- Management methods
- Assigning an IP address to the ICS-10X
- Logging on to the ICS-10X
3.1 Overview
This chapter gives an overview of converter management. The ICS-10X provides a simply WEB browser interface.
Using this interface, you can perform various converter configuration and management activities, including:
System
Network Configuration
Operation Mode
Serial Port Configuration
Please refer to the following Chapter 4 for more details.
3.2 Requirements
■ Network cables.
For ICS-100: Use standard network (UTP) cables with RJ45 connectors.
For ICS-102 / ICS-102S15: Use Multi-mode or Single Mode fiber patch cord with SC connectors.
■ Subscriber PC installed with Ethernet NIC (Network Card)
■ Workstations of subscribers running Windows 98/ME, NT4.0, 2000/2003/XP, MAC OS X or later, Linux, UNIX or
other platform compatible with TCP/IP protocols.
■ Above PC installed with WEB Browser, such as Microsoft Internet Explore or Mozilla Firefox
It is recommended to use Internet Explore 6.0 or above to access Serial Media
Converter.
-13-
User’s Manual of ICS-10x
3.3 Management Methods
Theway to manage the ICS-10X:
- Web Management via a network or dial-up connection
3.3.1 Web Management
The PLANET Web-Smart Media Converter provides a built-in browser interface. You can manage the ICS-10X remotely
by having a remote host with web browser, such as Microsoft Internet Explorer, Netscape Navigator or Mozilla Firefox.
Using this management method:
The ICS-10X must have an Internet Protocol (IP) address accessible for the remote host.
Figure 3-1 Web Management over Ethernet
3.3.2 Login the Media converter
Before you start configure the ICS-10X, please note the ICS-10X is con figured through an Ethe rnet connection, make su re
the manager PC must be set on same the IP subnet address.
For example, the default IP address of the ICS-10X is 192.168.0.100, then the manager PC should be set at 192.168.0.x
(where x is a number between 2 and 254), and the default subnet mask is 255.255.255.0.
1. Use Internet Explor er 6.0 or above Web browser. Enter IP add ress http://192.168.0.100 (the factory-default IP
address) to access the Web interface.
2. When the following login screen appears, plea se en ter the de fault u sername and pa ssword (defaul t use r name and
password is "admin"). Press Login to enter the main screen of ICS-10X. The login screen in Figure 3-1 appears.
Default IP Address: 192.168.0.100
Default Account: admin
Default Password: admin
-14-
User’s Manual of ICS-10x
Figure 3-2 Login screen
1. For security reason, please change and memorize the new password after this first setup.
2. Only accept command in lowercase letter under web interface.
-15-