Planet FNSW-1600, FNSW-B01ST, FNSW-2400, FNSW-B01SC Quick Installation Manual

0
10/100Mbps Switch
FNSW-1600 FNSW-2400
Modules
FNSW-B01ST / FNSW-B01SC
Quick Installation Guide
FCC Warning
These devices have been tested and found to comply with the limits for a class A digital device, pursuant to Part 15 of the
FCC Rules. These limits are designed to provide reasonable protection against harmful interface when the equipment is operated in a commercial environment. This equipment generates, uses an can radiate radio frequency energy and, if not installed and used properly may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at the user’ s own expense.
Revision
This installation guide is used for PLANET NOVASwitch series-
Model: FNSW-B01ST, FNSW-B01SC
Revision: 1.0 (July, 1999) Part No.: EMQFNSWB01
Copyright © 1999 Planet Technology Corp. Contents subject to revision without prior notice.
PLANET is a registered trademark of PLANET Technology Corp. The information in this manual is subject to change without notice. All other trademarks belong to their respective owners.
2
Part One: Outlooks, Check List & Features
Outlooks
Extension module for FNSW-1600/FNSW-2400
FDXHDX
100Base - FX
100Base - FX
FDX
HDX
ST /SC Interface
TX
RX
FNSW-B01ST/FNSW-B01SC: 1-port 100Base-FX switch extension module
Check List
The Module This Installation Guide
Part Two: Installation
Installation Steps
1. Cabling Guidelines Maximum length of a multi-mode fiber cable (62.5/
125µm) is:
2 kilometers (6560 feet) for full-duplex, or 412 meters (1351 feet) for half-duplex 100Base-FX
after module installed
2. Power off the FNSW-1600/FNSW-2400 and remove the
unit from the 19-inch rack.
3. Release the two screws to remove the module cover.
4. Slide in the module follows the chutes firmly. Secure the two
screws.
Extension Slot
Full-Duplex
Half-Duplex
5. Put back the switch.
6. Make the fiber connection follow the cabling guidelines
above. Note, please check the duplex mode (Full/Half­Duplex) of the device that is going to attach to and adjust the DIP-switch.
7. Make sure the port#9 or port#13 is free. Then power on
the unit and the connected devices, the Link LED indicator of port#9/#13 will blink “Orange” to indicate module installed and the fiber port has detected a good link.
Note: The LINK LED indicator of port#9/#13 will shows steady
Orange” as a good link and will blink “Orange” if there is any network activity in this port. This is especially designed to indicate this port is with fiber module installed. For this port, please leave the description in the section “LED indicator” of the switch’ s guide.