Quick Installation Guide for Ethernet Lightning Arrest Box
Thank you for purchasing PLANET Ethernet Lightning Arrest Box ELA-100, the Eth-
ernet Lightning Arrest Box package shall contain following contents:
Check the contents of your package for following parts:
Ethernet Lightning Arrest Box x1
Quick Installation Guide x1
Ground cable x1
If any of these pieces are missing or damaged, please contact your dealer imme-
diately, if possible, retain the carton including the original packing material, and
use them against to repack the product in case there is a need to return it to us
for repair.
Please refer to following procedure and picture to install the Ethernet Lightning
Arrest Box between two Ethernet devices.
Step 1:
In the right side, please use ground cable from package to connect the screw
and ground.
Step 2:
Please connect rst Ethernet device to the protected port that near the screw
through the UTP cable.
Step 3:
Please connect second Ethernet device to un-protected port from other
side of Ethernet Lightning Arrest Box.
1

Quick Installation Guide for Ethernet Lightning Arrest Box
Figure 1: ELA-100 Application
Notice:
1. Please install this device at outdoor with shelter.
2. This Ethernet Lightning Arrest Box must be earthed. If not. this device may
with electric shock and cause damage.
2

Quick Installation Guide for Ethernet Lightning Arrest Box
Specification
Model
Ethernet Interface
Ground
DC spark-over voltage
Nominal impulse discharge
current ( wave 8/20μs)
Arc Voltage at 1A
Glow to arc transition current
Glow voltage
Dimension (W x D xH)
Weight
Operate/Storage environment
Table 1: Specification of ELA-100
ELA-100
2 passive 10/100/1000 Ethernet Ports
1 ground position
230V, ±20%
20KA
~35V
~1A
~200V
65 x 42 x 20mm
80g
-40~70 Degree C, 5%~90%RH