Project_________________________
Item No.________________________
Quantity________________________
Model FBG18 and FBG24 Flat Bottom Gas Fryers with Filtration
Model FBG18 and FBG24
Flat Bottom Gas Fryers with Filtration
Unit shown is FBG18/FD/FBG24
STANDARD FEATURES & ACCESSORIES
Tank - heavy duty gauge mild steel
Cabinet-stainless steel front, door, sides & splash back.
Blower Free Burner Technology
Solid State Temperature Controller with matchless ignition,
melt cycle, and drain valve interlock switch.
1 ¼” (3.2 cm) Full port drain valve
Manual gas shutoffs and Rear gas manifold connection
Built-in integrated flue deflector
9” (22.9 cm) Legs
Drain plug
Removable flue splash guard
Drain Line Clean out rod
Cleaning brush
Filter scoop shovel
Filter powder and fryer cleaner sample packets
Filter paper envelope 18-1/2” x 20-1/2” (47 x 57cm)
sample packet – 25 sheets
OPTIONS & ACCESSORIES AT ADDITIONAL COST
Stainless Steel back
9” (22.9 cm) swivel adjustable rear and front casters
Flexible gas hose with disconnect
Tank cover
Flush hose
Paperless stainless steel mesh filter
Crumb Tray - rear mount
Perforated pan divider
Filter heater for solid shortening
STANDARD SPECIFICATIONS
CONSTRUCTION
Fry tank constructed of heavy gauge mild steel
for stickless wet batter frying.
Welded tank with an extra smooth peened finish
ensures easy cleaning.
Stainless steel cabinet front, door, side and splash back
Heavy duty 3/16” (.48 cm) door hinges
Marine front edge to hold wet batter trays
Front 1 ¼” (3.2 cm) full port drain for quick draining.
9” (22.9 cm) bottom clearance allows for ease of cleaning.
CONTROLS
Blower Free Burner Technology provides dependable heat
transfer without the need for complex power blowers.
Integrated gas control valve acts as a manual valve, pilot
valve, main valve, gas filter and pressure regulator.
Gas control valve prevents gas flow to the main burner
until pilot is established and shuts off all gas flow
automatically if the pilot flame goes out.
Temperature limit switch safely shuts off all gas flow if the
fryer temperature exceeds the upper limit.
Solid State Thermostat mounted behind the front door.
A compact temperature controller incorporating automatic
melt cycle, system indicator lights and power switch.
Matchless ignition ignites a standing pilot once a day when
the power is turned on. Less wear and tear on components
and faster recovery when the controller calls for heat.
Drain valve interlock switch is hermetically sealed switch
that automatically shuts down the heating system if the
drain valve is opened.
FILTER SYSTEM
Extra Large 3” (7.6 cm) curved drain spout virtually
eliminates splashing and swivels for oil disposal.
Filter pan is stainless steel with rear wheels for easy
movement during cleaning.
Connection to fryer is self-aligning for ease of use.
Easy two step filtering. 1) Red handle to drain tank
2) Yellow Handle to return oil.
High flow pump and large return lines produce faster oil
refill times.
Filter pump thermally and overload protected
Filter pan lid stows in the cabinet and out of the way.
Battery up to 5 Flat Bottom fryers per filter.
Pitco Frialator, Inc • P.O. Box 501, Concord, NH 03302-0501 • 509 Route 3A, Bow, NH 03304
603-225-6684 • FAX: 603-225-8497 • www.pitco.com
L10-220 Rev 1 02/07 Printed in the USA
Model FBG18 and FBG24 Flat Bottom Gas Fryers with Filtration
Model FBG18 and FBG24 Flat Bottom Gas Fryers with Filtration
FBG18
FBG24
Models
FBG18/FBG24 (
FBG18/FBG18 530 Lbs (240.4 kg) 57 x 43 x 55 in (144.7 x 104.1 x 132.0 cm)
FBG24/FBG24 665 Lbs (301.6 kg) 55 x 43 x 68 in (139.7 x 109.2 x 172.7 cm)
Filter drawer
shipped separately
Supply Pressure *
* Check plumbing / gas codes for proper gas supply line sizing to sustain burner pressure when all gas appl iances are full on.
Front min. Floor min. Combustible material
30"
(76.2 cm)
Provide Pitco model FBG18 and FBG24 Flat Bottom Gas Fryer with Filtration. Fryer shall have an blower free burner technology system.
Unit shall have a deep flat bottom cook depth up to 5" (12.7 cm ). Fryer cooking area shall be 18 x 24 (45.7 x 61 cm) for a FBG18 or 24 x
24 (61 x 61 cm) for a FBG24. Heat transfer area shall be a minimum of 864 sq. inches (5574 sq. cm) for the FBG18 and 1152 sq. inches
(7432 sq. cm) for the FBG24. Drain line shall have a round 3" (7.6 cm ) diameter with a swivel drain spout for oil disposal. High flow filter
Offers versatile cooking of wet batter products like fish & chips, tempura, funnel cakes, and other conventional fried products.
Frying Area Burner PressureCook Depth Oil Capacity Gas Input Rate / HrModels
18 x 24 in
(45.7 x 61cm)
24 x 24 in
(61 x 61cm)
shown above
GAS FRYER REQUIREMENTS ELECTRIC SYSTEM REQUIREMENTS
(15.25 cm)
) 590 Lbs (267.6 kg) 57 x 43 x 55 in (144.7 x 104.1 x 132.0 cm)
Fryers can be batteried up to five (5) units, please consult factory for shipping information.
Natural Gas LP Gas
7 - 10" W.C.
(17.4 mbars/ 1.74 kPa)
6"
6" (15.2cm) 6" (15.2cm)
pump with self aligning filter pan connection and easy 2 step filtering for faster oil refill times.
INDIVIDUAL FRYER SPECIFICATIONS
3-1/4 - 5 in
(8.3 - 12.7cm)
3-1/4 - 5 in
(8.3 - 12.7cm)
42 - 65 Lbs
(19 - 29.5 kg)
57 - 87 Lbs
( 25.6 - 39.5 kg)
100,000 BTUs
(28.3kW) (105MJ)
120,000 BTUs
(35.1kW) (127MJ)
10 mbars/1kPa
(
FRYER SHIPPING INFORMATION
Shipping Crate Size H x W x L
90 Lbs (40.8 kg) 30 x 35 x 47 in (76.2 x 88.9 x 119.3 cm)
INSTALLATION INFORMATION
115V 60Hz 208 / 220-240V 50-60 hz
3.5 1.9
7.3 4.7
11 - 13" W.C.
(27.4 mbars/ 2.74 kPa)
Fryer Cord (1 of 2)
(Total Amps Max.)
Filter Cord (2 of 2)
Total Amps Max.
CLEARANCES
Non-Combustible material
Sides min.
0" 0"
Rear min.Sides min. Rear min.
Do not block / restrict flue gases from flowing into hood
Fryer Flue Area
or instal l vent hood d rains over the f lue.
SHORT FORM SPECIFICATION
TYPICAL APPLICATION
4" W.C.
)
LPNat
10" W.C.
25 mbars/2.4kP
(
Shipping CubeShipping Weight
78.0 ft3 (2.2 m3 )
78.0 ft3 (2.2 m3 )
3
93.1 ft
(2.6 m3 )
28.6 ft3 (0.8 m3 )
a)
Pitco Frialator, Inc • P.O. Box 501, Concord, NH 03302-0501 • 509 Route 3A, Bow, NH 03304
603-225-6684 • FAX: 603-225-8497 •
W We reserve the right to change specifications without notice and without incurring any obligation for equipment previously or subsequently sold.
www.pitco.com L10-220 Rev 1 02/07 Printed in the USA