There are three different types of notices that you should be familiar with, a NOTICE, CAUTION,
and WARNING. A NOTICE is a special note used to call attention to a particularly important point.
CAUTION is used to point out a procedure or operation which may cause equipment damage. The
WARNING notice is the most important of the three because it warns of an operation that may cause
personal injury. Please familiarize yourself with your new cooker before operating it and heed the
notices throughout this manual. The WARNINGS are listed below and on the following page for your
review prior to operating the unit.
FOR YOUR SAFETY
DO NOT store or use gasoline or other flammable
vapors or liquids in the vicinity of this or any other
appliance.
WARNING: Improper installation, adjustment, alteration, service or maintenance can cause property damage, injury or death. Read the installation, operating
and maintenance instructions thoroughly before installing or servicing this equipment.
TO THE PURCHASER
POST IN A PROMINENT LOCATION INSTRUCTIONS TO
BE FOLLOWED IN THE EVENT THAT AN OPERATOR
SMELLS GAS. OBTAIN THIS INFORMATION FROM YOUR
LOCAL GAS SUPPLIER.
THIS MANUAL MUST BE RETAINED FOR FUTURE REFERENCE
SAFETYSAFETYSAFETYSAFETYSAFETY
WARNING
The cooker must be electrically grounded in accordance with local
codes. If local codes do not apply, follow the requirements of
National Code ANSI/NFPA 70-1990.
WARNING
This cooker is equipped with a three prong safety plug. This safety plug
protects operators from electrical shock in the event of an equipment malfunction. DO NOT remove the grounding (third) prong from this plug.
WARNING
DO NOT use an open flame to check for gas leaks!
WARNING
ENGLISH
A cooker that is equipped with casters and a flexible power cord must be
connected to the gas supply with a Quick-Disconnect device. This quick
disconnect must comply with ANSI Z24.41-1989. A restraining cable must
be installed to limit the movement of the cooker.
WARNING
There is an open gas flame inside the cooker. The unit may get hot enough
to set nearby materials on fire. Keep the area around the cooker free from
combustible materials.
WARNING
Ensure that the cooker can get enough air to keep the flame burning correctly.
If the flame is starved for air it can give off dangerous carbon monoxide.
Carbon Monoxide is a clear odorless gas that can cause suffocation and death.
WARNING
Be sure the burner tubes are COMPLETELY covered with water before
lighting the pilot or main burners. If the tubes are exposed, the cooker may
overheat, causing damage to the kettle, creating a fire hazard, and voiding the
warranty.
SAFETYSAFETYSAFETYSAFETYSAFETY
SAFETYSAFETYSAFETYSAFETYSAFETY
WARNING
Carbon monoxide can build up if the flue is blocked. Blocking the flue will
also cause the cooker to overheat. Ensure that minimum clearances specified
in the installation instructions are maintained. DO NOT obstruct the flow of
combustion/ventilation or air opening around the Noodle Cooker. Adequate
clearance around the cooker is necessary for servicing and proper burner
operation. Ensure that you meet the minimum clearances specified in the
installation instructions.
WARNING
The power supply must be disconnected before servicing or cleaning the
appliance.
WARNING
For gas cookers, DO NOT supply the cooker with a gas that is not listed on
the data plate. If you need to convert the cooker to another type of fuel, contact
your dealer.
WARNING
For gas cookers, WAIT five (5) minutes before attempting to relight the pilot.
This allows time for any gas remaining in the cooker to dissipate.
THIS MANUAL MUST BE RETAINED FOR FUTURE REFERENCE
SAFETYSAFETYSAFETYSAFETYSAFETY
Chapter 1: General Information and Installation
Congratulations on the purchase of your new 40S fryer. This unit will give you many years of reliable
service if you follow the simple operation and maintenance procedures in this manual. Contained in
this manual are the general installation, operation, and maintenance procedures for the 40S fryer.
1.1WHICH FRYER DO I HAVE?
There are two models of this gas fryer available. Each fryer has its own model number. To find out
which model you have, look inside the door at the equipment identification plate. This plate has a lot
of useful information, but to identify which fryer you have, look at the model number block. The model
number identifies which fryer you have. A brief description of each model is provided inTable 1-1.
Table 1-1 Fryer Model Information
Model
Number
40S & 40C
This fryer can cook up to 72 lbs. of potatoes per hour.
Description
Features
Frying Area: 14" x 14"
Oil Capacity: 40 lbs.
BTU Input: 105,000
ENGLISH
1.2CHECKING YOUR NEW FRYER
Your new fryer has been carefully packed into one crate. Every effort has been made to ensure that
your fryer is delivered to you in perfect condition. As you unpack your new fryer, inspect each of the
pieces for damage. If something is damaged, DO NOT sign the bill of lading. Contact the shipper
immediately, the shipper is only responsible for 15 days after delivery. Check the packing list enclosed
with your fryer to ensure that you have received all of the parts to the fryer. If you are missing any parts,
contact the dealer from whom the fryer was purchased. As you unpack the fryer and it's accessories
be careful to keep the weight of the fryer evenly distributed.
CAUTION
To prevent equipment damage, don't tilt the fryer onto
any two of it's casters or pull the unit by the flue vents.
X
1-1
X
1.2.1Check Your Order
The crate containing the fryer unit will also contain the following:
(1)Drain Clean Out Rod
1.3ASSEMBLY AND LEVELING
When you receive your fryer, it is completely assembled with the possible exception of the legs (or
casters) and the heat shield. In some cases, if you have purchased a multi-fryer unit, you may need to
assemble the system.
1.3.1Leg/Caster Installation and Adjustment
Installing the legs and leveling the fryer is done with a 7/16" wrench, socket, and a large pair of water
pump pliers. The legs/casters must be installed to provide the necessary height to meet sanitation
requirements and assure adequate air supply to the burner. Attach the legs by performing the following
procedure.
a. Lay the fryer on its side being careful not to damage the flue
by pulling on it. Protect the outside of the fryer with
cardboard or a drop cloth when laying it down.
b. Attach each leg/caster with the hex head cap screws sup-
plied with the fryer. Each leg/caster requires four 1/4-20 x
5/8" cap screws.
c. Mount the screws from the inside of the fryer with the nut
on the outside. The nuts have lock washers attached to
them, therefore it is not necessary to use lock washers.
d. When all four legs/casters are mounted, stand the unit up
being careful not to put too much weight on any one leg/
caster. Adjust the height and level the fryer by adjusting the
leveling devices on the leg/caster with the water pump
pliers.
e. On units with casters, move the fryer to the desired location
and lock the wheels using the locking devices on the sides
of the casters.
1.3.2Assembling Multi Fryer Systems
1-2
Adjust
Here
Adjust Here
Lock
Un Lock
If you purchased a multi-fryer unit, it could be shipped in more than one piece. To assemble the unit
follow the instructions below.
a. Unpack the units and move them close together. Remove the front panels and both heat
shields from the fryers.
b. There are five joining strips to be attached to the units to make them into one system. These
strips are attached in the rear, front, upper front, and the forward and rear caster mount. Use
the screws supplied with your system to attach the strips. Secure them tightly to each unit.
c. Replace the heat shield and front panels to complete the system assembly.
1.4INSTALLATION
Although it is possible for you to install and set up your new fryer, it is STRONGLY recommended
that you have it done by qualified professionals. The professionals that install your new fryer will know
the local building codes and ensure that your installation is safe.
WARNING
The fryer must be properly restrained to prevent movement or tipping. This
restraint must prevent the fryer from movements that would splash hot liquids
on personnel. This restraint may be any means (alcove installation, adequate
ties, or battery installation).
ENGLISH
1.4.1Installation Clearances
The fryer needs clearance around it for proper operation. Adequate clearances allow for servicing and
proper burner operation. The clearances shown below are for cooker installation in combustible and
non-combustible construction.
Your fryer will give you peak performance when the gas supply line is of sufficient size to provide the
correct gas flow. The gas line must be installed to meet the local building codes or National Fuel Gas
Code (NFPA 54-Latest Edition) and ANSI Z223.1-Latest Edition Latest Edition. In Canada, install
the fryer in accordance with CAN/CGA-B149.1 or .2 and local codes. Gas line sizing requirements
1-3
can be determined by your local gas company by referring to National Fuel Gas Code, Appendix C,
Table C-4 (natural gas) and Table C-16 (propane). The gas line needs to be large enough to supply
the necessary amount of fuel to all appliances without losing pressure to any appliance. Other factors
that are used to determine the piping requirements are BTU requirements of the appliances being
connected and the length of pipe between the meter (main shut off) and the appliances.
WARNING
NEVER supply the fryer with a gas that is not indicated on the data plate. Using
the incorrect gas type will cause improper operation. If you need to convert the
fryer to another type of fuel, contact your dealer.
1.4.2.1Fuel Types - Each fryer is equipped to work with one type of fuel. The type of fuel with
which the appliance is intended to operate is stamped on the data plate attached to the inside of the door.
WARNING
DO NOT use an open flame to check for gas leaks!
1.4.2.2Gas Line Connection - Connect the fryer to the gas supply line with a connector that
complies with the Standard for Connectors for Movable Gas Appliances (ANSI Z21.69-Latest
Edition). If you are installing a fryer with casters use a quick disconnect refer to the Quick Disconnect
installation instruction, 1.4.2.3. Connect the gas line to the fryer using a pipe joint sealant that is resistant
to liquefied petroleum. If the fryer was disconnected during the fuel line testing, use a solution of soap
and water to leak test the new connection.
NOTICE
NEVER use an adaptor to make a smaller gas supply line fit the cooker
connection. This may not allow proper gas flow for optimum burner operation,
resulting in poor cooker performance.
1.4.2.3Quick Disconnect Gas Connection - Gas fryers equipped with casters must be installed
with connectors that comply with the Standard for Connectors for Movable Gas Appliances, ANSI
Z21.69-Latest Edition, and Addenda Z21.69A-Latest Edition. This connection should include a
quick disconnect device that complies with the Standard for Quick Disconnect Devices for Use
With Gas Fuel , ANSI Z21.41-Latest Edition. When installing a quick disconnect you must also
install a means for limiting the movement of the fryer. This device will prevent the gas line or the
quick disconnect from being strained. The restraining device should be attached to the cooker on
the back panel as shown in the illustration. The quick disconnect, hose, and restraining device can
be obtained from your dealer.
1.4.2.4Fuel Supply Line Leak and Pressure Testing - The fuel supply system must be tested before
the fryer is used. If the fuel line is going to be tested at a pressure greater than (>)1/2 PSIG (3.45 kPa),
1-4
make sure that the fryer is disconnected from the fuel line. If the fuel line is to be tested at a pressure
equal to or less than (<) 1/2 PSIG (3.45 kPa), the fryer can be connected but the unit's gas valve must
be shut. Test all gas line connections for leaks with a solution of soap and water when pressure is
applied.
1.4.3Ventilation and Fire Safety Systems
Your new fryer must have proper ventilation to function safely and properly. Exhaust gas temperatures
can reach as high as 1200°F. Therefore, it is very important to install a fire safety system. Your
ventilation system should be designed to allow for easy cleaning. Frequent cleaning of the ventilation
system and the fryer will reduce the chances of fire. Table 1-2 provides a list of reference documents
that provide guidance on ventilation and fire safety systems. This table is not necessarily complete.
Additional information can be obtained from the American Gas Association, 8501 East Pleasant Valley
Road, Cleveland, OH 44131.
Excessive ventilation causes drafts, which will interfere with the proper operation of the pilot and
the burner. Leave at least 18 inches of open space between the fryer's flue vent opening and the
intake of the exhaust hood.
CAUTION
ENGLISH
Ensure that your ventilation system does not cause a down draft at the fryer's
flue opening. Down drafts will not allow the fryer to exhaust properly and will
cause overheating which may cause permanent damage. Damage caused by
down drafts will not be covered under equipment warranty. NEVER allow
anything to obstruct the flow of combustibles or ventilation exiting from the
fryer flue. DO NOT put anything on top of the flue area.
NOTICE
NEVER connect the blower directly to the flue openings. The direct flow of
air will cause poor temperature recovery, poor ignition, inefficient operation of
the fryer, and could extinguish the pilot.
1.5INITIAL ADJUSTMENTS
After your fryer has been installed as described in section 1.4, it needs to be adjusted to ensure that it
will perform as designed. These adjustments must be performed by a qualified person. To perform
these adjustment the following tools will be needed:
• Manometer (low pressure gauge)• Digital Thermometer (Temperature probe)
• DC Millivolt Meter
1.5.1Visual Checks
1-5
After the fryer is in its permanent location, lock the casters and check for levelness. Any additional
leveling that is necessary can be performed as described in section 1.3.
1.5.2Burner Ignition Systems
CAUTION
Before going any further, fill the fryer with WATER. Water is used for the
installation adjustments because the temperature will never exceed 212°F
(100°C) thereby allowing plenty of adjustment time. Never let the water level
go below the MIN LEVEL mark on the rear of the tank.
WARNING
There is an open flame inside the fryer. The unit may get hot enough to set near
by materials on fire. Keep the area around the fryer free from combustibles.
To light the pilot light, refer to these instructions.
Table 1-2. Ventilation and Fire Safety References
Topic
Grease Extractor
Ventilation Hood
Type of Fire Extinguishers
and Detection Equipment
CO
2
Dry Chemical
Water
Foam
Sprinklers
Smoke Detectors
Underwriters Laboratory
Document
ANSI/UL 710-Latest Edition
ANSI/UL 705-Latest Edition
ANSI/UL 154-Latest Edition
ANSI/UL 299-Latest Edition
ANSI/UL 626-Latest Edition
ANSI/UL 199-Latest Edition
ANSI/UL 268-Latest Edition
National Fuel Gas Code
Document
ANSI/NFPA 96-Latest Edition
ANSI/NFPA 96-Latest Edition
ANSI/NFPA 12-Latest Edition
ANSI/NFPA 17-Latest Edition
ANSI/NFPA 13-Latest Edition
ANSI/NFPA 11-Latest Edition
ANSI/NFPA 13-Latest Edition
ANSI/FPA 72B-Latest Edition
Fire Detection Thermostats
ANSI/UL 521-Latest Edition
1-6
ANSI/FPA 72B-Latest Edition
WARNING
Wait 5 minutes before attempting to relight the pilot to allow for any gas in the
fryer to dissipate.
a. Open the gas supply valves to the fryer.
b. Open the fryer's door to gain access to the controls. Turn the thermostat control knob
counterclockwise to the OFF position.
c. Turn the Unitrol valve knob to the PILOT position and push in on the knob. Hold the knob
in for approximately one minute to purge the air out of the line. Hold a
flame to the pilot light until the pilot ignites. This may take a little while
the first time you light the fryer because of air in the lines. Once lit, hold
the knob in for approximately 60 seconds and then release.
d. If the pilot goes out wait 5 minutes and repeat step c. If after three tries
the pilot will not remain lit, refer to the operator troubleshooting section
of this manual.
e. Turn the Unitrol valve knob counterclockwise to the ON position.
f.Set the thermostat control knob to the desired temperature setting.
g. The main burner will light and be controlled by the thermostat.
h. To completely shut down the fryer, turn the Unitrol valve knob to pilot,
push in and continue turning to OFF.
1.5.2.1Pilot Flame Adjustment - The pilot flame should be adjusted to produce the proper millivolt
output from the pilot sensing device. Millivolt output for the thermopile should be between 300 and
500 millivolts. This procedure is only necessary on the manual pilot ignition system. Figure 1-1 shows
the pilot assembly with examples of the incorrect and correct pilot size. Example A illustrates a pilot
flame size that is too small to produce sufficient millivolt output. Example B is the correct size for proper
millivolt output.
ENGLISH
a. This test requires a DC millivolt meter set to a scale of 0-1000mv.
b. Locate the thermopile wires coming from the thermostat/High Limit box going to the gas
shut off valve. The wire insulation size decreases near the gas valve connections.
c. Connect the negative (-) test probe to pilot bracket.
1-7
d. Connect the positive (+) test probe to to one of the High Limit terminal connections
e. Remove the pilot flame adjustment cover.
f.Turning the flame adjusting screw clockwise lowers the flame and the millivolt output.
Turning the screw counterclockwise increases flame size and millivolt output.
g. Rotate the screw in the direction to achieve a reading of 400 ±50 mv for thermopiles.
NOTICE
Allow 3 to 5 minutes between flame adjustments to allow the reading to settle.
h. Replace the pilot flame adjusting screw cover.
1.5.3Main Burner System
For the burners to work, the gas supply valve must be open. The main burner receives gas from the
main gas supply through the thermostatically controlled valve. When the thermostat is turned up the
gas control valve opens. The pilot ignites the burners. The burner flame should be adjusted at the air
collar (at the bottom of the burner) so the the flame are a soft blue color without lifting off the face of
the burner.
1.5.3.1Gas Line Requirements - A properly installed gas supply system will deliver 7.0 ±2.0" w.c.
natural gas (12.0 ±2.0" w.c. LP) to all appliances connected to the line, operating at full demand.
1.5.3.2Burner Adjustment - The burners must be adjusted to deliver optimum flame. Adjust the
burner flame using the following procedure.
a. Ensure that the Unitrol valve knob is in the OFF position. Remove the manifold pressure
BA
Figure 1-1 Pilot Assembly, Flame Adjustment
1-8
tap plug and connect an accurate pressure gauge (range of 0-16" w.c. in 0.1" increments)
or manometer.
b. Light the pilot burner (see 1.5.2) for the unit being tested and adjust the thermostat to light
the main burners.
c. The installed pressure gauge reading should be the same, ±0.1", as that marked on the data
plate inside the door. If the pressure is correct go to step e, if not, adjust the pressure.
d. To adjust the pressure, remove the regulator adjustment screw cover (see Figure 1-3). Use
a flat tip screwdriver to adjust the screw until the proper pressure is reached. Turning the
screw clockwise will increase the pressure, counterclockwise will decrease the pressure.
e. When the pressure is correct, install the regulator adjustment screw cover.
f.To remove the pressure gauge, turn gas control valve to OFF. Remove the gauge and install
the pressure tap plug.
g. Now that the pressure is set for proper operation, set the main burner flame. Unlock the air
collars by loosening the set screw for the collars. See Figure 5. Turn the Unitrol valve knob
to ON and turn thermostat to light the main burners.
h. Adjust the shape and size by raising or lowering the air collars to achieve a soft blue flame
with well defined inner cones.
i.When the flames have been properly adjusted, lock the collars in place with the set screw
provided.
ENGLISH
1.5.4Initial Cleaning
When the fryer is shipped, many of its parts are covered with a thin coat of oil for protection. Before
the fryer is ready for cooking it must be cleaned. This will remove the oil coating and any foreign matter
that may have accumulated during storage and shipment. Perform the cleaning as described below.
a. Fill the tank with water and add one packet of mild detergent.
Figure 1-2 Gas Valve
Showing Location of the
Pressure Regulator and
Pilot Adjusters
1-9
b. Turn the fryer on and set the thermostat to 200°F. Allow the fryer to heat for 15 minutes.
NOTICE
Do not leave the fryer unattended during cleaning. Never let the water level go
below the "Min Level" mark on the back of the tank.
c. Using the fryer cleaning brush, scrub the inside of the fryer to remove protective coating.
d. When cleaning is complete, turn off the fryer main burners and turn the Unitrol valve knob
to the PILOT position. Drain the water into a container suitable for hot water and dispose
of it.
e. When the tank has cooled, rinse it thoroughly with cool water. Continue to rinse the tank
until the cleaner has been rinsed, thoroughly from the tank.
f.Using a clean dry cloth, wipe out all of the water. Be very thorough removing the water,
because any residual water will cause hot oil to splatter out of the fryer.
CAUTION
Mild steel tanks must be wiped down/coated with oil to keep the tank from
rusting.
g. Now that the tank is clean, you are ready to fill and operate the fryer. Refer to 2.1 for
instructions on adding shortening to the fryer.
1.5.5Thermostat Calibration Check
NOTICE
Thermostat calibration requires that the temperature of the fryer be raised above
boiling. Therefore, you will need to drain the water from the fryer and fill it with
oil. Before removing the water, perform the initial cleaning of the fryer.
Cleaning the fryer now will prevent you from having to drain the oil and refill
with water later.
Filling the fryer with oil is described in 2.1. To perform the calibration check detailed below you will
need a digital thermometer.
a. Place the tip of the thermometer in the shortening approximately 1" above the temperature
sensors.
b. Set the thermostat at 325°F and wait for the temperature reading on the thermometer to rise.
1-10
As the temperature rises toward 325°F watch the thermometer closely.
c. If the shortening temperature reaches 350°F and the burners DO NOT turn off, turn the
thermostat down. Keep lowering the thermostat setting until the burners go out.
If the burners do not turn off at the lowest thermostat setting, the thermostat
could be defective. Contact your representative immediately.
d. Let the fryer cycle 4 to 6 times before checking the temperature. Compare the thermometer
temperature against the thermostat setting. If the values are more than 5°F apart, calibrate
the thermostat using the appropriate calibration procedure in this manual.
1.5.6Thermostat Calibration
a. Place the tip of the thermometer in the shortening approximately 1" above the temperature
sensors.
b. Set the Thermostat to 325°F and wait for the temperature reading on the thermometer to rise.
c. Let the fryer cycle 4 to 6 times to ensure that the temperature has stabilized. Compare the
thermometer temperature against the thermostat setting. If the values are more than 5°F
apart, calibrate the thermostat using the appropriate calibration procedure.
CAUTION
ENGLISH
1-11
1-12
Chapter 2: Operating Instructions
This chapter describes how to operate your fryer to obtain the best performance. Included in this
chapter are filling, operating, and cleaning instructions for gas fryers.
2.1FILLING THE FRYER
Both liquid and solid shortening can be used in the fryer, but liquid is preferred. To melt solid
shortening, carefully follow the instruction in section 2.2.2.
2.1.1Filling the Fryer With Liquid Shortening
a. Make sure the drain valve is completely closed.
b. Fill the fryer with oil to the "Oil Level" line marked
on the back of the tank.
2.1.2Filling the Fryer With Solid Shortening
WARNING
Never melt blocks of solid shortening on top of the burner
tubes. This will cause a fire and will void your warranty.
a. Make sure the drain valve is completely closed.
b. Remove the screen covering the tubes.
c. Cut the shortening into cubes no larger than 1".
ALWAYS pack the shortening below, between,
and on top of the burner tubes. DO NOT leave any
large air gaps. Use care when packing the solid
shortening in the tank. DO NOT bend or break the
temperature sensor probes. If these are damaged
the fryer will not function properly.
ENGLISH
d. Once the fryer is packed with shortening, the short-
ening must be melted. To melt the shortening, refer
to Fryer Start-Up, section 2.2.1, and Melting Solid
Shortening, section 2.2.2.
2-1
2.2OPERATING INSTRUCTIONS
To ensure the food always comes out the very best, follow the preparation instructions for the food
you are cooking. Using the best shortening makes the best fried foods. The best shortening will last
longer than lower grade shortening and save you money. When not in use the shortening should be
cooled and covered to prevent contamination.
CAUTION
The fryer has been installed using restraining devices to prevent accidental
tipping or movement. Do not attempt to move the fryer when it has hot liquid
in it. Splashing hot liquids can cause severe burns.
WARNING
Water and shortening DO NOT mix. Keep liquids away from hot shortening.
Dropping liquid frozen food into the hot shortening will cause violent boiling.
2.2.1Fryer Start-Up
DO NOT START FRYER WITHOUT FILLING WITH OIL!
a. Light the pilot light as described in section 1.5.2.
b. Turn the temperature control knob (thermostat) to the desired temperature setting. This
knob is located behind the front doors or on the front control panel.
c. The main burners will light.
2.2.2Melting Solid Shortening
The melting procedure below requires cycling of the fryer. Watch carefully
for smoke. If smoke is noticed, the shortening is scorching. To prevent this,
decrease the time you leave the burners on.
a. Place the Unitrol valve in ON position.
b. Set thermostat to 150°F.
c. Allow main burners to fire for approximately four (4) seconds.
NOTICE
d. Turn thermostat down until main burners go out.
2-2
e. Wait 30 seconds.
f.Repeat steps c. through e. until the shortening is melted.
g. Set thermostat to normal operating temperature. The burners will remain on constantly
until the shortening temperature reaches the thermostat setting.
h. Once at temperature, the fryer is now operating normally and ready to use.
2.2.3Fryer Shut-Down
There are two shutdown modes of fryer operation, STANDBY and COMPLETE. The standby mode
removes the ability for the fryer's main burners to cycle. Complete shutdown turns off the gas supply
to the fryer. Shut down the fryer by:
STANDBYTurn the thermostat to OFF. Turn the gas valve clockwise to the
PILOT position. The cooker is now in Standby and can remain this
way for only brief periods of time. NEVER leave the cooker in
standby overnight.
COMPLETE To completely shut down the cooker, push and turn the gas valve
counterclockwise to the OFF position. The fryer is now completely
shut down and can be cleaned and filtered.
2.3DAILY CLEANING
Your fryer should be cleaned every day to maintain peak performance and appearance. Perform the
procedures below every day.
a. Wipe up any shortening that spills onto the exterior of the fryer. This should be done with
a clean soft cloth while the oil is still warm.
ENGLISH
b. Use warm water with a mild detergent to clean surfaces. Be careful not to get water in
the shortening and to remove any detergent from the fry tank.
c. Use a non-abrasive scouring powder or pad to clean stains if necessary.
d. Perform the weekly boil out cleaning of your fryer described in section 3.2.
2-3
Chapter 3: Owner Maintenance and Adjustments
This chapter provides you with the information and procedures necessary to perform basic fryer
maintenance and adjustments. If, after performing maintenance on your fryer, it does not perform
properly, contact your authorized service center.
3.1WEEKLY FRYER CLEANING (BOIL OUT)
The fryer should be thoroughly cleaned once a week. This cleaning should include a complete draining
of the fryer and a boil out.
a. You will need a container large enough to hold 1 1/2 times the oil in one tank. This container
should also be able to withstand boiling water temperatures.
CAUTION
Completely shut down the fryer when the oil is to be replaced by water, and
when the heating portion of the cleaning is complete. This will prevent the
heating system from coming on during the oil draining and water filling
procedure.
b. Drain the oil from the fryer and discard or save for reuse. Remove tube rack/mesh tube
screens and remove any large debris from the bottom of the fry tank. Once clean, return
tube rack/mesh screens to the fry tank. Close the drain valve and fill the fry tank with water
and noncaustic detergent.
c. Restart your fryer as described in 2.3 and set the thermostat to 200°F and bring the water
to a slow boil. DO NOT allow water to boil because excessive foaming will occur. Once
the water is at a slow boil turn off the fryer.
d. Allow the fryer to soak for 20 minutes to soften shortening deposits and carbon. Use the
fryer brush to remove any residue from tank, heating tubes, and side walls. Perform the
daily cleaning procedure described in section 2.6.
e. Wipe the tank dry with clean cloth wipes. Close the drain valve and remove the large
container.
f.Refer to section 2.1 to refill the fryer.
3.2FLUE INSPECTION
It is recommended that once every six months, with the cooker cooled down, you examine the flue area.
Check for corrosion or blockage of the flue. Ensure that the cooker is shutdown and do not turn it on
during the examination. Examination of the flue area during cooking may cause bodily injury.
3-1
3.3TROUBLESHOOTING
This section is provided to aid you in the event of fryer or filter troubles. If these troubleshooting
procedures do not correct your problem contact a qualified technician or the factory. The troubleshooting procedures are in a flowchart format.