SOLSTICE SUPREME (SSH) SERIES
SSH55(R), 55T(R), 60(R), 60W(R), 75(R) Gas Fryers
SSH55T
w/optional
Digital and
rear casters
SSH60WR
w/optional
I12 Computer
and casters
SSH55
w/standard
Solid State
**ENERGYSTAR
STANDARD FEATURES & ACCESSORIES
Tank - stainless steel construction
Cabinet - stainless front, door and sides
Solstice Burner Technology, No blower or ceramics
High Efficiency design, EnergyStar performance
Patented Self Cleaning Burner & Down Draft
Protection
Solid State T-Stat with melt cycle & boil out mode
Matchless Ignition automatically lights the pilot when
the power is turned on and saves you money during
off times
DVI drain valve interlock safety system turns the
heat off preventing the oil from scorching /
overheating.
High Temperature safety limit switch
Heavy duty 3/16” bottom door hinge
1 ¼” (3.2 cm) Full port drain valve for fast draining
Separate Manual gas shutoffs, for front servicing
Integrated flue deflector
9” (22.9 cm) adjustable legs, easier access to clean
Tube rack, allows crumbs & debris into cool zone
Removable basket hanger, requires no tools
Drain Line Clean out rod
Drain Extension
Fryer cleaner sample packet
Choice of basket options :
2-Twin Baskets
1-Full Basket
(not available on SSH55T or Basket Lifts)
SSH75 w/optional
Computer, Basket Lift
and casters
®
Models
Project_________________________
Item No._________________________
Quantity_________________________
HIGH EFFICIENCY SERIES OF GAS FRYERS
For Energy Saving High Production Frying specify Pitco
Model SSH55(R),55T(R),60(R),60W(R),75(R) tube fired gas
fryers with Solstice Supreme Burner Technology which
provides very dependable atmospheric heat transfer and fuel
saving ENERGYSTAR
complex power blowers. This patented atmospheric burner
system with its long lasting alloy heat baffles reaches up to
70% thermal efficiency and delivers lower flue temperatures.
New Patented Self Cleaning Burner goes through a daily 30
second cleaning cycle to keep your burners tuned to operate
in the most energy efficient manner. Ventilation troubles are
virtually eliminated with the Patented Down Draft Protection
that safely monitors your fryer, making this a low
maintenance, highly reliable fryer. High volume restaurants
and multi-store chains can benefit from lower operational
energy cost and lower annual maintenance and repair cost.
**
®
performance without the need for
MODELS AVAILABLE
55 Series (40-50 lbs, 14” x 14” fry area)
SSH55** (80 Kbtu/hr, 23.4 kW, 88 MJ)
SSH55R (100 Kbtu/hr, 29.3 kW, 105 MJ)
55T Twin Vat Series (20-25 lbs, 7” x 14” fry area/side)
SSH55T (40K btu/hr, 11.7 kW, 44 MJ /side)
SSH55TR (50K btu/hr, 14.6 kW, 53 MJ /side)
60 Series (50-60 lbs, 14” x 18” fry area)
SSH60** (80K btu/hr, 23.4 kW, 88 MJ)
SSH60R (100K btu/hr, 29.3 kW, 105 MJ)
60W Series (50-60 lbs, 18” x 14” fry area)
SSH60W** (100K btu/hr, 29.3 kW, 110 MJ)
SSH60WR (125K btu/hr, 36.6 kW, 132 MJ)
75 Series (75 lbs, 18” x 18” fry area)
SSH75** (105K btu/hr, 30.8 kW, 116 MJ)
SSH75R (125K btu/hr, 36.6 kW, 132 MJ)
OPTIONS & ACCESSORIES (AT ADDITIONAL COST)
Digital Controller (2 timers w/melt cycle)
Intellifry I-12 Computer (12 elastic timers w/melt & boil out)
Backup thermostat (only on Digital and I-12 computer)
Basket Lift (must be ordered with Digital Control or Computer)
(To meet AGA/CGA/CSA specification, must be ordered with casters & installed with
flexible gas hose w/restraining cable)
Stainless Steel back (not available with basket lift)
9”(22.9 cm) adjustable,non-lock rear & front lock casters
Flexible gas hose with disconnect and restraining cable
Tank cover
3-Triple Baskets (not available on 55T or Basket Lifts)
Consult Factory for other basket configurations
Splash Guard reversible (L/R) 6" 8" 12" 18"
Work Shelves call factory for specifications and availabilty
Fish Grids (not available on 55T)
Institutional Prison security package
BNB Dump Station, see BNB spec sheet L10-269
Filter System options (See Spec Sheet):
Filter drawer (L10-134) SoloFilter (L10-267)
SPINFRESH, see spec sheet L10-524 for details
SOLSTICE SUPREME (SSH) SERIES SSH55(R), 55T(R), 60(R),60W(R),75(R) Gas Fryers
Pitco Frialator, Inc P.O. Box 501, Concord, NH 03302-0501 509 Route 3A, Bow, NH 03304
603-225-6684 FAX: 603-225-8497 www.pitco.com
L10-266 Rev 4 04/12 Printed in the USA
SOLSTICE SUPREME (SSH) SERIES SSH55(R), 55T(R), 60(R), 60W(R), 75(R) Gas Fryers
SSH55 (R)
48 11/32 [122.8]
A
B
C
SSH55T (TR)
15 5/8 [39.7]
4 1/4 [10.8]
B
SSH75 (R)
52 11/32 [132.9]
19 5/8 [49.8]
6 1/4 [15.9]
OPTIONAL
DIGITAL
CONTROL
SOLID STATE
THERMOSTAT
SSH60 (R)
48 11/32 [122.8]
15 5/8 [39.7]
4 1/4 [10.8]
38 11/32 [97.4]
34 15/32 [87.5]
INTEGRAL FLUE DEFLECTOR
OPTIONAL BASKET LIFT
IN/CM
SSH60W (R)
52 11/32 [132.9]
19 5/8 [49.8]
6 1/4 [15.9]
11/16
[1.7]
54 13/32
[138.2]
NOM.
P
3/4 INCH GAS CONNECTION
(CE 3/4 INCH BSP ADAPTOR
G
ADDS 1 1/2 [3.8] TO
CONNECTION)
6 FOOT (183 CM) POWER
CORD (NEMA 5-15 PLUG
P
115VAC UNITS ONLY)
P
A
34 [86.4]
NOM.
G
12 13/16
[32.5]
9 [22.9]
NOM.
NOM.
C
4 13/32 [11.2]
G
46 1/8
[117.1]
NOM.
10 1/2
[26.7]
NOM.
1 13/32 [3.6]
INDIVIDUAL FRYER SPECIFICATIONS
Cook Depth Oil CapacityModel Frying Area
14 x 14 in (35.6 x 35.6 cm)
7 x 14 in (35.6 x35.6cm)
14 x 18 in (35.6 x 45.7 cm)
18 x 14 in (45.7 x 35.6 cm)
18 x 18 in (45.7 x 45.7 cm)
3-1/4 - 5 in (8.3 -12.7 cm)
3-1/4 - 5 in (8.3 -12.7 cm)
3-1/4 - 5 in (8.3 -12.7 cm)
3-1/4 - 5 in (8.3 -12.7 cm)
3-1/4 - 5 in (8.3 -12.7 cm)
40 - 50 Lbs (18 - 23 kg)SSH55, 55R
20 - 25 Lbs (9 -11 kg)SSH55T, 55TR per side
50 - 60 Lbs (23 - 27 kg)SSH60, 60R
50 - 60 Lbs (23 - 27 kg)SSH60W, 60WR
75 Lbs (34 kg)SSH75, 75R
FRYER SHIPPING INFORMATION (Approximate)
Model
SSH55T, SSH55TR
SSH60, SSH60R
SSH60W,SSH60WR
SSH75, SSH75R
SOLSTICE SUPREME (SSH) SERIES SSH55(R), 55T(R), 60(R), 60W(R), 75(R) Gas Fryers
Gas Type
Natural
Propane
* Check plumbing / gas codes for proper gas supply line sizing to sustain burner pressure when all gas appliances are full on.
Shipping Weight
Add for Each Bsk/Lifts
308 Lbs (140 kg) SSH55, SSH55R 208 Lbs (94.5 kg)
230 Lbs (104 kg)
226 Lbs (102.5 kg)
275 Lbs (124.5 kg)
275 Lbs (124.5 kg)
330 Lbs (150 kg)
326 Lbs (149 kg)
376 Lbs (171 kg)
376 Lbs (171 kg)
59 x 23 x 44 in (149.8 x 58.4 x 111.7 cm)
INSTALLATION INFORMATION
GAS SYSTEM REQUIREMENTS ELECTRIC SYSTEM REQUIREMENTS (50/60 hz)
Store Supply Pressure *
7 - 10" w.c.(17.4 mbars/ 1.7 kPa)
11 - 13" w.c.(27.4 mbars/ 2.7 kPa)
Burner Manifold Pressure # of Cord
4" w.c. (10 mbars / 1 kPa)
10" w.c. (25mbars/2.4 kPa)
Amps 208 / 220-240V 115V
Fryer
Shipping CubeShipping Crate Size H x W x L
34.6 ft
CLEARANCES
30"
(76.2 cm)
6"
(15.25 cm)
Combustible material
Sides min. Rear min.
Sides min.
6" (15.2cm) 6" (15.2cm) 0"
Rear min.
0"
Do not block / restrict flue gases from flowing into hood
or install vent hood drains over the flue.
Fryer Flue AreaFront min. Floor min. Non-Combustible material
SHORT FORM SPECIFICATIONS
Provide Pitco Solstice Supreme Model (SSH xxx) tube fired high efficiency / high production gas floor fryer with ENERGYSTAR
xx-xx lbs oil capacity, xxx Kbtu/hr, xx” by xx” fry area, stainless peened tank, stainless f ront , door, sides. Patented Blower Free atmospheric burner system
with up to 70% thermal efficiency, Patented self cleaning burners, down draft protection, matchless ignition, drain valve interlock, behind the door solid stat e tstat with melt and boil mode (or specify optional digital controller or computer controls), separate gas shut of f, 3/4" npt rear gas connect, recessed cabinet
back, 1-1/4" Full port drain, 3/16" bottom hinge, 9” adjustable legs, manual reset high limit. If supplied with casters: Casters with 1" min. adjustment and front
toe locks. Provide opt ions and accessories as follows:
®**
performance. Fryer shall be
3
. (1.0m3 )
0.40.71
Pitco Frialator, Inc P.O. Box 501, Concord, NH 03302-0501 509 Route 3A, Bow, NH 03304
603-225-6684 FAX: 603-225-8497 www.pitco.com
We reserve the right to change specifications without notice and without incurring any obligation for equipment previously or subsequently sold.
L10-266 Rev 4 04/12 Printed in the USA