PHONIC XP 600, XP 1000, XP 2000, XP 2100, XP 3000, XP 3100, XP 5000, XP 5100 User Manual
XP 600 XP 1000
XP 2000 XP 2100
XP 3000 XP 3100
XP 5000 XP 5100
POWER AMPLIFIER
AMPLIFICADOR DE POTENCIA
功率放大器
XP 5100
User’s Manual
Manual del Usuario
使用手册
English / Español / 简体中文
XP 600/1000/2000/2100/3000/3100/5000/5100
POWER AMPLIFIER
AMPLIFICADOR DE POTENCIA
功率放大器
CONTENTS
INTRODUCTION........................4
FEATURES.................................4
INSTALLATION...........................4
FRONT PANEL DESCRIPTION.5
REAR PANEL DESCRIPTION....5
SPECIFICATIONS......................8
DIMENSIONS...........................23
BLOCK DIAGRAMS..................25
CONTENIDO
INTRODUCCION..............................11
CARACTERISTICAS........................11
INSTALACIÓN..................................11
DESCRIPCIÓN DE PANEL FRONTAL
DESCRIPCIÓN DE PANEL DORSAL
ESPECIFICACIONES......................15
DIMENSIONES................................23
DIAGRAMAS DE BLOQUE..............25
...12
.....13
目录
简介................................18
特色................................18
安装................................18
正面板功能说明..............19
背面板功能说明..............19
规格................................21
尺寸................................23
线路图............................25
Phonic preserves the right to improve or alter any information within this document without prior notice
Phonic se reserva el derecho de mejorar o alterar cualquier información provista dentro de este documento sin previo aviso
PHONIC保留不预先通知即可更新本手册的权利
V1.0 11/28/2008
1. Read these instructions befo re operating this
apparatus.
2. Keep these instructions for future reference.
3. Heed all warnings to ensure safe operation.
4. Follow all instructions provided in this document.
5. Do not use this apparatus near water or in locations
where condensation may occur.
6. Clean only with dry cloth. Do not use aerosol or liquid
cleaners. Unplug this apparatus before cleaning.
7. Do not block any of the ventilation openings. Install
in accordance with the manufacturer’s instructions.
8. Do not install near any heat sources such as radiators,
heat registers, stoves, or other apparatus (including
.
9. Do not defeat the safety purpose of the polarized or
grounding-type plug. A polarized plug has two blades
with one wider than the other. A grounding type plug
has two blades and a third grounding prong. The wide
blade or the third prong is provided for your safety. If
the provided plug does not into your outlet, consult
an electrician for replacement of the obsolete outlet.
10. Protect the power cord from being walked on or
pinched particularly at plug, convenience receptacles,
and the point where they exit from the apparatus.
11. Only use attachments/accessories by the
manufacturer.
12. Use only with a cart, stand, tripod, bracket, or
table by the manufacturer, or sold with
the apparatus. When a cart is used, use caution
when moving the cart/apparatus
combination to avoid injury from tipover.
13. Unplug this apparatus during lighting
storms or when unused for long
periods of time.
14. Refer all servicing to service personnel.
Servicing is required when the apparatus has been
damaged in any way, such as power-supply cord or
plug is damaged, liquid has been spilled or objects
have fallen into the apparatus, the apparatus has
been exposed to rain or moisture, does not operate
normally, or has been dropped.
IMPORTANT SAFETY INSTRUCTIONS
CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK,
DO NOT REMOVE COVER (OR BACK)
NO USER SERVICEABLE PARTS INSIDE
REFER SERVICING TO QUALIFIED PERSONNEL
The lightning flash with arrowhead symbol, within an
equilateral triangle, is intended to alert the user to the
presence of uninsulated “dangerous voltage” within the
product
’
magnitude to constitute a risk of electric shock to persons.
The exclamation point within an equilateral triangle is in-
tended to alert the user to the presence of important operat-
ing and maintenance (servicing) instructions in the literature
accompanying the appliance.
WARNING: To reduce the risk of or electric shock, do
not expose this apparatus to rain or moisture.
CAUTION: Use of controls or adjustments or performance
of procedures other than those may result in
hazardous radiation exposure.
The apparatus shall not be exposed to dripping or splashing and that no objects with liquids, such as vases,
shall be placed on the apparatus. The MAINS plug is used as the disconnect device, the disconnect device shall
remain readily operable.
Warning: the user shall not place this apparatus in the area during the operation so that the mains switch
can be easily accessible.
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
INTRODUCTION
Thank you for choosing XP series power amplier. The unit is
designed to provide a good combination of power, audio clarity,
reliability and durability. An efcient heat-dissipation system
comprising a high-surface area heat sink coupled with two
variable speed fans ensures quiet and reliable cooling. Good
sound quality and sturdy construction make this unit ideal for
a multitude of amplication tasks; from studio installations to
mobile DJs, house of worship and touring bands. In order to
get the best performance out of your XP series power ampli-
er, please read this user’ s manual carefully, and retain it for
future reference.
COOLING
Two variable-speed fans would start running as soon as the power
is being turned on. Before mounting your amplier, you should
familiarize yourself with its cooling requirements. The air ows from
the front to the back, so it is important not to block the amplier
front air vents. If the amplier is rack-mounted, leave some space
in front of the rack to prevent heated air being drawn back into
the front-to-back airow. Airow restrictions are the most common cause of inadequate cooling. They may result from improper
mounting, bundles of power cords, clogged dust lters and closed
rack doors. Mount the amplier to allow sufcient airow out the
front outlets to ensure your amplier work properly.
FEATURES
● Advanced powerful performance- third generation
circuitry design
● High continuous current output from robust toroidel
transformer
● Switchable input peak limiter and selectable high pass lter
(30 Hz, 50 Hz) to reduce distortion and protect speakers
● Signal level at -40, -20, -10, protect and clip LED
indicators to monitor performance
● Bridge mono and parallel mode LEDs
● Fast Recovery design for lower distortion if clipping occurs
● Active balanced inputs for low noise
● XLR/TRS connectors for maximum input exibility
● Barrier strip input connectors on the XP5000 and XP5100
for permanent installations
● Speakon and 5-way binding post speaker outputs
● 2 ventilation variable speed fans
● Very rugged housing
● Fits a standard 19” rack
WIRING
The balanced XLR and TRS input connectors will accept the
line-level output of most devices for ultimate input convenience.
The amplier built-in XLR and TRS connectors can be wired similarly for balanced or unbalanced, oating or ground-referenced
sources. The output connector is a binding post with Speakon
which provides an easy connection when using banana plugs,
spade lugs or bare wires.
INSTALLATION
MOUNTING
The power amplifier can be inst alle d in a standard 19-
in c h equipment rac k . It re q uires 3 units (5.25 inc h es)
for the XP 200 0/210 0, XP 3000/ 3100, and 2 units (3.5
inches) for the XP600/1000 of verti cal rac k space and
se c ur es to th e r a ck cab i net wi t h f our ra c k m oun t
screws and cup washers. In a rack, it is best to mount
units one above the other, with at least a unit of space at least
between two ampliers. This provides efcient airow and support.
4XP 600/1000/2000/2100/3000/3100/5000/5100
FRONT PANEL DESCRIPTION
POWE R
C
--33 22
--1166
--1144
-6
0
10-
--2200--2200--2200--2200
--4400--4400--4400--4400
PROTEC T
CLIP/
LIMI
T
NNOORRMMAALL
60
90
12
0
SUB
WOOFER
10-
--2200--2200--2200--2200
--4400--4400--4400--4400
--33 22
--1166
--1144
6
0
PROTEC T
CLIP/
LIMIT
NNOORRMMAALL
60
90
120
SUB
WOOFER
1. CLIP/LIM LED (RED)
When the audio signal drives the amplier output circuit beyond
its power capability, it will clip. The peak limiter detects this and
quickly reduces the gain to minimize the amount of overdrive, so
as to preserve as much of the program dynamics as possible.
2. PROTECT LED (YELLOW)
The power amplier features several types of protection to prevent damage to the circuitry during turn-on or fault conditions.
The power-on protection relay prevents damaging thumps to the
speakers as the power comes on. When the amplier is switched
on, the protect LED will light for a few seconds, and then go out,
indicating that the relay has closed, connecting the speakers to
the amplier.
The protect LED will also come on if the speaker terminals are
short circuited, or the impedance of the load between them is
too low. Under these circumstances, the protect LED will stay on
until the fault condition is rectied.
If the amplier’ s large heat sinks go down for thermal reasons,
leave the power connected to the amplier, try to improve ventila-
tion, and reduce the gain. Without power, the fan cannot oper-
ate, and the amplier will require longer to reach a low enough
temperature to restart.
3. SIGNAL LED (GREEN)
Each channel of the power amplier features a signal light to show
that how much of an audio signal has been put in to the channel.
The threshold for the indicator is -40dB, above that, noise will
trigger the LED to light.
4. GAIN CONTROL
These two knobs are the level controls for each channel of the
amplier. The gain increases as the knob is turned clockwise.
This unit features detented gain controls.
5. POWER SWITCH
Although the XP series ampliers feature power-on muting, it is
always a good practice to reduce both the gain controls before
turning on the amplier. The powering-up procedure for an audio
system should start from instruments and then mixer, and you
should verify that all system operations are normal before turn-
ing on the amplier.
6. SUBWOOFER SWITCH (XP2100/3100/5100 ONLY)
NORMAL/60/90/120Hz
Switching from normal to either 60Hz, 90Hz or 120Hz setting will
add the dedicated low pass lter to the output path, which offers
you a sub bass output to achieve a 3-way or more ways speaker
system. When you activate this function, you will get the subwoofer
frequency output below 60Hz, 90Hz or 120Hz only. On the XP5100
this switch is located on the rear of the amplier.
7. DISPLAY
When the power is on, the PHONIC logo at the top of the front
panel will light up in green.
When the amplier is switched to the bridge mono mode, the
bridge LED right next to the PHONIC logo will light up in red.
When the amplier is switched to the parallel mode, the parallel
LED next to the bridge LED will light up in yellow.
5XP 600/1000/2000/2100/3000/3100/5000/5100
REAR PANEL DESCRIPTION
8. FAN
These two variable speed fans automatically maintain safe internal temperature. Keep the front and rear vents clear to allow
full airow. Hot air will be drawn out theback of the amplier, so
it does not stay in the rack, and make sure plenty of cool air can
enter the rack.
9. RESET BREAKER
With rated loads and output levels, the breaker should only shut
down the amplier in rare instances of catastrophic failure. The
circuit breaker can also shut down the amplier in cases where
extremely low-impedance loads and high output levels result in
a current draw that exceeds its rating.This feature is not included
on the XP600.
10. POWER CORD
All units are shipped with an appropriate plug and cord for the
required AC voltage. This product is equipped with a 3-wire
grounding type plug. This is a safety feature and should not be
defeated. Check the AC voltage before connecting the plug.
11. CHASSIS GROUNDING CONNECTING POINT
Please refer to your local safety code for proper grounding.
12. OUTPUT CONNECTORS
A pair of versatile binding posts and Speakon connectors are
provided for output connection to each channel. Loudspeakers can be easily connected using banana plugs, spade lugs,
bare wires or Speakon connector. Spade lugs and bare wires
should both be screwed down tightly to avoid a short circuit. The
Speakon connector for channel 1 includes channel 1, channel 2
and bridged mono pin connecting points. A pin out information
could be foundbeside the Speakon connector.
13. INPUT CONNECTORS
The power amplier offers XLR and TRS input connectors for your
connecting convenience. On the XP5000 and 5100, users will also
nd barrier strip inputs. Barrier strip inputs should be screwed
down tight as to not let oxygen enter the connection. These are
best used in long term or permanent installations.
14. GROUNDING - FLOATING SWITCH
This switch allows the circuit and chassis grounding to be sepa-
rated in case of a grounding conict. In normal use, the switch
should be in the grounding on position. Lifting the grounding
(to what is called the oating position) may resolve the ground
conict, but it means that circuit grounding depends on other connected equipment. Deciencies in other components’ grounding
will affect the sound quality and cause a grounding loop hum.
For the best combination of safety and performance, it is highly
recommended to set the switch at the “grounding on” position.
15. LIMITER ON/OFF
This switch allows you to route the peak limiter circuit to the input
signal. This function will reduce distortion and protect speakers.
This switch is not included on the XP5000 or XP5100.
16. HPF
This switch can activate a 30Hz or 50Hz high pass lter, which
will roll off signals below either 30 Hz or 50 Hz. This improves sub
bass performance by limiting sub bass cone motion. It will make
more power available for the speakers’ rated frequency range. This
switch is not included on the XP5000 or XP5100.
6XP 600/1000/2000/2100/3000/3100/5000/5100
17. PARALLEL / STEREO / BRIDGE MONO SWITCH
Turn off the power before changing the operation mode. In ste-
reo operation, each channel of the amplier runs independently
with its own signal and speakers. When the switch is set to the
parallel mode, the input of CH2 is paralleled with that of CH1.
Then, CH1 and CH2 can drive their own speakers independently,
but they will have the same source, that of CH1. In bridge mono
operation, both channels can be congured to drive a single
load with a single signal at twice the power. Use the following
procedure to ensure the systems safety when switching from
one mode to another:
1.Turn off the power of the amplier
2.Put one speaker, of not less than 4 ohms impedance,
across the red (+) output terminals of the amplier.
3.Ensure that there is only one input signal connected
to CH1.
4.Switch the amplier to bridge mono.
5.Turn the gain controls of CH1 and CH2 to the
extreme left and then turn on the amplier.
6.Verify operation at low gain, and then turn up the
CH1 gain to increase power to a desired level.
This switch is not included on the XP5000 or XP5100.
18 . M O DE S WI TC H ES ( X P 50 00 / X P5 10 0 o nl y)
7XP 600/1000/2000/2100/3000/3100/5000/5100
SPECIFICATIONS
XP 600XP 1000XP 2000 / XP 2100 XP 3000 / XP 3100
Stereo Mode (driving both channels)Continuous Average Output Power Per Channel
PROTECT: Yellow LED Green LED for -10dB, -20dB and -40dB Signal Lights
Front panel controlsCH1 & CH2 GAIN knobs with 41 detents; selectable low frequency crossover at 60Hz,
Amplier ProtectionShort circuit, thermal, subsonic, RF protection, Output DC offset, Heatsink and
transformer over-heat protection, Power on/off muting, Soft start power on
Gain32x (30dB)40x (32dB)
Power Consumption150W293W880W1460W
Dimensions (WxHxD)482.6 x 89 x 367.2mm
below rated power
Distortion (Typical) 1kHz and below: full
rated power
Frequency Response20Hz-20kHz, 8 ohms, LF lter bypassed, +0/-1dB
5Hz to 50kHz, 8ohms, LF lter bypassed, +0/-3 dB
Damping Factor>250 @ 8 ohms
Noise (unweighted)100 dB below rated output (20 Hz to 20kHz, 8 ohms load)
Input sensitivity1.42 Vrms for 1000 watts into 8 ohms
Control FontAC power switch, Ch1 & Ch2 gain control with 41 detents
Control Rear12-pole DIP switch featuring high pass lter on/off, high pass lter 30/50Hz, Clip Limiter
on/off control for each channel and switches for selecting Stereo, Parallel, or Bridge
Mode. Push-button circuit breaker for each channel. Slide switch for Grounding /
Floating (Selectable low pass lter frequency at 60Hz, 90Hz and 120Hz, XP5100 only)
Voltage Gain41x (36dB)
Input Impedance20k ohms balanced, 10k ohms unbalanced
IndicatorsPower-On: Amber Phonic logo; Parallel: Green backlight icon; Bridged: Red back-
light icon; CLIP/LIM: Red LED;
PROTECT: Yellow LED Green LED for -10dB, -20dB and -40dB Signal Lights
Connectors InputXLR, 1/4”TRS jacks and barrier strip
Connectors OutputBinding posts and speakon outputs (Ch1 speakon wired for biamp)
CoolingContinuous variable-speed fan, rear-to-front air owAmplier ProtectionShort circuit, open circuit, thermal, ultrasonic, and RF protection. Stable into mis-
Load Protectionon/off muting, DC fault output crowbar
Output CircuitryCalss H Amplier
Power Requirements (depends on region)100-120VAC, 220-240VAC (+/- 10%), 50/60Hz (factory congured); 120V model
Circuit Breakerstwo (one for each channel): 100 and 120V models: 20 amp / 230 V models: 10 amp
Dimensions (WxHxD)482.6 x 133 x 415 mm (19” x 5.2” x 16.3”)
Weight28.2 kg (62.1 lbs)
<0.02%
<0.02%
matched loads
requires 20 amp
9XP 600/1000/2000/2100/3000/3100/5000/5100
9
Loading...
+ 19 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.