Type NO.

 

Mounting

1Phase Vol 3Phase Vol Frenquency Max Current

Figure

L(mm)

 

IP

 

 

 

1

3

 

 

 

 

 

RCS350 3C L1000 WH

 

Surface

220~240V

380V~415V

50/60Hz

16A

A

1000

1.2

IP20

RCS350 3C L2000 WH

 

Surface

220~240V

380V~415V

50/60Hz

16A

A

2000

2.4

IP20

RCS350 3C L3000 WH

 

Surface

220~240V

380V~415V

50/60Hz

16A

A

3000

3.6

IP20

ZRS350 3C TCP WH T COUPLER

Surface

220~240V

380V~415V

50/60Hz

16A

E

 

0.2

IP20

ZRS350 3C CPX WH X COUPLER

Surface

220~240V

380V~415V

50/60Hz

16A

F

 

0.14

IP20

ZRS350 3C CCP WH L COUPLER

Surface

220~240V

380V~415V

50/60Hz

16A

D

 

0.14

IP20

ZRS350 3C EPS WH SUPPLY

Surface

220~240V

380V~415V

50/60Hz

16A

B

 

0.07

IP20

ZRS350 3C CPS WH SUPPLY CENTRAL

Surface

220~240V

380V~415V

50/60Hz

16A

C

 

0.27

IP20

A

 

 

126

 

 

 

 

 

 

 

 

42.5

 

 

 

 

 

 

 

 

 

34

 

 

 

 

L

 

 

 

 

 

B

 

 

C

 

 

D

103.7

 

 

 

 

 

 

 

 

 

 

 

 

 

30.8

 

42.5

 

41.5

 

42.5

35.7

 

 

35.7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

34

 

 

 

 

34

 

 

34

 

 

102.5

 

 

 

185

 

 

 

 

 

 

 

 

 

120

 

 

 

 

 

 

70

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

113.7

 

 

 

 

 

 

 

 

 

42.5

 

 

E

185

 

 

F

 

41.5

 

41.5

 

 

 

 

 

 

 

 

 

 

 

41.5

 

 

 

34

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

34

 

 

 

185

 

185

 

 

 

 

 

 

 

 

 

 

 

 

120

 

 

 

 

 

 

 

 

 

 

 

42.5

 

 

 

 

 

 

 

 

113.7

 

 

 

 

120

 

42.5

 

 

 

1.Ensure that the luminaire is consistent with the track system in electric ,machine and temperature when mounting and using.

,

2.The track system is only used to the track projector luminare of Philips.

Philips Lighting Luminaires (Shanghai) Co., Ltd. Address: No. 2688, Huyi Road, Jiading, Shanghai, China Postalcode: 201801

2688

201801

1

a

b

 

 

 

 

 

L=1000mm

L=1000mm

 

 

100

200

 

 

 

Ø3.5

50N 50N 50N 50N 50N 50N

50N 50N 50N 50N 50N 50N

 

 

 

 

2

 

1

 

1

2

2

3

 

 

5

a

 

 

220~2401V, 6A, 3.5~3.8 KW

 

 

 

 

1

 

 

 

L

2

 

L1

L2

3

 

 

 

N

L3

N

Max.16A

 

 

 

 

1-circuit(1 )

 

220V, 16A, 3x3.5 KW

Out 220/In 380V, 16A, 10.6 KW

 

230V, 16A, 3x3.7 KW

Out 230/In 400V, 16A, 11.0 KW

 

240V, 16A, 3x3.8 KW

Out 240/In 415V, 16A, 11.5 KW

 

 

 

 

L2

 

L2

b

 

L1

 

L1

 

 

L3

Max.16A

L3

 

 

N

N

Max.16A

 

 

3-circuit(3 )

 

3-phase(3 )

 

When the track connect 3 phase supply, the load for every phase must be so equal that 3 phase voltage be balanceable