Philips TC70 User manual

Page 1
7
1Parts and Supplies
The part numbers for all replacement parts and supplies for the PageWriter TC70 cardiograph are listed in this section.
This chapter provides the following information:
Ordering Replacement Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 -1
Replacement Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-2
Other PageWriter TC Cardiograph Replacement Parts . . . . . . . . . .7-5
Patient Interface Module (PIM) and Patient Data Cable
Replacement Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-6
Supplies and Ordering Information . . . . . . . . . . . . . . . . . . . . . . . . .7-7
Ordering Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-7
Special Note about Welsh Bulb Electrodes. . . . . . . . . . . . . . . .7-8
PageWriter TC Cardiograph Supply Part Numbers . . . . . . . . .7-8
Ordering Options and Upgrades . . . . . . . . . . . . . . . . . . . . . . . . . .7-12
Contacting a Philips Response Center. . . . . . . . . . . . . . . . . . . . . .7-13
Ordering Replacement Parts
Inside the United States, please contact the Philips Response Center for assistance ordering replacement parts. See “Contacting a Philips Response Center” on page 7-12.
Outside the US, contact your local Philips Medical Systems Response Center. See “Contacting a Philips Response Center” on page 7-12.
7-1
Page 2
Parts and Supplies Replacement Parts
Replacement Parts
Figure 7-1 Replacement Parts Exploded Diagram
1
2
3
18
4
6
7
8
9
10
5
11
12
13
14
15
17
7-2 PageWriter TC70 Cardiograph Repair Manual
16
19
Page 3
Parts and Supplies Replacement Parts
Table 7-1 Replacement Parts
Reference Number Part Number Description
1 453564094201 Display assembly 2 453564096481 Display rubber plugs 3 453564124581 Display hinges 4 453564096421 Hinge cover 5 453564094281 PageWriter TC70 Keyboard Assembly
English (USA)
5 453564094291 PageWriter TC70 Keyboard Assembly
(European)
5 453564094301 PageWriter TC70 Keyboard Assembly
(French)
5 453564215081 PageWriter TC70 Keyboard Assembly
(Russian) 6 453564096401 Plastic cover top housing 7 453564110481 Printer assembly 8 N/A (see reference number 19) Metal plate (not a replaceable part, comes
with bottom housing kit) 9 453563479161 Compact Flash memory, 1GB 10 453564094221 Main board 11 453564096321 Wireless LAN Card cover 12 453564096251 Wireless LAN Card 13 453564096241 Modem 14 453564096451 I/O Module 15 453564096411 Battery latch assembly 16 453564096391 Battery door 17 453564096471 Internal USB cable 18 453564096351
453564096361
Paper drawer assembly A
Paper drawer assembly A4 19 453564096381 Bottom housing (includes metal plate)
PageWriter TC70 Cardiograph Repair Manual 7-3
Page 4
Parts and Supplies PageWriter TC70 Cardiograph Cart Replacement Parts
PageWriter TC70 Cardiograph Cart Replacement Parts
Figure 7-2 PageWriter TC70 Cardiograph Cart Replacement Parts
Table 7-2 PageWriter TC70 Cardiograph Cart Replacement Parts List
Reference Number Part Number Description
1 989803159011* Cart Patient Cable Arm
7-4 PageWriter TC70 Cardiograph Repair Manual
Page 5
Parts and Supplies Other PageWriter TC Cardiograph Replacement Parts
Table 7-2 PageWriter TC70 Cardiograph Cart Replacement Parts List (continued)
Reference Number Part Number Description
2 989803149561* Additional Cart Storage Bin 3 and 4 453564054291 Directional locking caster 5 453564050721 Swivel caster 6 453564054301 Full locking caster 7 989803159001
* Additional Wire Basket
8 453564094411 Cart power supply 15V, 80W
NOTE The parts listed in that contain an asterisk (*) after the part number are only available through your
sales representative or distributor.
Other PageWriter TC Cardiograph Replacement Parts
Table 7-3 Other PageWriter TC Cardiograph Replacement Parts
Part Number Description
453564119001 Cardiograph to trolley mounting screws and washers (2) 453564096331 Assorted screws consisting of:
M3 x 8mm T10 (20) M3 x 6mm T10 (2, for I/O board assembly) M4 x 8mm T 20 (6) Display rubber plugs (4)
PageWriter TC70 Cardiograph Repair Manual 7-5
Page 6
Parts and Supplies Patient Interface Module (PIM) and Patient Data Cable Replacement Parts
Patient Interface Module (PIM) and Patient Data Cable Replacement Parts
Before ordering a replacement PIM or patient data cable, check the Service Number on the bottom PIM label. The Service Number determines which replacement PIM or patient data cable part number is ordered. For information on Class A and Class B PIMs and patient data cables, see “About Class A and Class B Patient Data Cables and PIMs” on page 1-21. Please have the Service Number information available, and then call the nearest Philips Response Center for assistance with ordering a replacement PIM or patient data cable. For a listing of Philips Response Center phone numbers, see “Contacting a Philips Response Center” on page 7-12.
Figure 7-3 Service Number on PIM Label (bottom of PIM)
Service Number
7-6 PageWriter TC70 Cardiograph Repair Manual
Page 7
Parts and Supplies Supplies and Ordering Information
Supplies and Ordering Information
The part numbers for all supplies for the PageWriter TC cardiograph are listed in this section.
Ordering Supplies
All supplies may be ordered on the web at:
http://shop.medical.philips.com
Use the part numbers listed in this section to ensure that the correct supplies are ordered.
Special Note about Welsh Bulb Electrodes
Figure 7-4 Welsh Bulb Electrode
Welsh Bulb electrodes are offered as an optional supply part with the PageWriter TC cardiograph. Special care is necessary when using these electrodes. Pay special attention to all warnings associated with these electrodes. For information on cleaning the reusable Welsh Bulb electrodes, see “Reusable Electrode Cleaning" on page 3-4. Philips Medical Systems recommends the use of disposable electrodes with the PageWriter TC cardiograph.
WARNING The Welsh bulb electrodes (available as an accessory for the cardiograph) do not meet
the requirements of IEC 60601-2-25 for defibrillation recovery time, and cannot be reliably used for patient diagnosis immediately following defibrillation.
WARNING Always clean and disinfect reusable electrodes before patient use. See “Reusable
Electrode Cleaning” on page 3-4 for information on cleaning and disinfecting reusable electrodes. Failure to properly clean and disinfect reusable electrodes before patient use may cause infectious materials to be transferred between patients.
CAUTION The Welsh bulb electrodes contain natural rubber latex which may cause allergic reactions.
PageWriter TC Cardiograph Supply Part Numbers
PIM Patient Data Cable
Part Number Description
989803164281 Patient Data Cable, 8-pin (2.0 meters/6.56 feet length) (Class B)
PageWriter TC70 Cardiograph Repair Manual 7-7
Page 8
Parts and Supplies Supplies and Ordering Information
PIM Patient Data Cable
Part Number Description
989803158481 Patient Data Cable, 5-pin (2.0 meters/6.56 feet length) (Class A)
Complete Lead Sets
Part Number Description
989803151631 Complete AAMI Lead Set for Standard 12 Leads (arm lead 99
cm/39 in, leg lead 104.1 cm/41 in, chest leads 69.8 cm/27.5 in)
989803151641 Complete IEC Lead Set for Standard 12 Leads (arm lead 99 cm/
39 in, leg lead 104.1 cm/41 in, chest leads 69.8 cm/27.5 in)
989803151711 Limb Lead Set (AAMI/IEC) (arm lead 99 cm/39 in, leg lead 104.1
cm/41 in)
989803151671 Complete Chest Lead Set (AAMI/IEC) (chest leads 69.8 cm/27.5
in)
989803151651 Long Complete AAMI Lead Set for Standard 12 Leads (arm lead
137.1cm/54 in, leg lead 142.2 cm/56 in, chest leads 69.8 cm/27.5 in)
989803151661 Long Complete IEC Lead Set for Standard 12 Leads (arm lead
137.1cm/54 in, leg lead 142.2 cm/56 in, chest leads 106.6 cm/42 in)
989803151731 Long Limb Lead Set (AAMI and IEC) (arm lead 137.1cm/54 in,
leg lead 142.2 cm/56 in) 989803151691 Long Chest Lead Set (AAMI/IEC) (chest leads 106.6 cm/42 in) 989803151751 16-Lead Kit for AAMI Leads (arm lead 99 cm/39 in, leg lead
104.1 cm/41 in, chest leads 69.8 cm/27.5 in, extended leads 83.8
cm/33 in) 989803151761 16-Lead Kit for IEC Leads (arm lead 99 cm/39 in, leg lead 104.1
cm/41 in, chest leads 69.8 cm/27.5 in, extended leads 83.8 cm/33
in) 989803151771 Long 16-Lead Kit for AAMI Leads (arm lead 137.1cm/54 in, leg
lead 142.21 cm/56 in, chest leads 106.6cm/42 in, extended leads
121.9cm/48 in)
989803151781 Long 16-Lead Kit for IEC Leads (arm lead 137.1cm/54 in, leg
lead 142.21 cm/56 in, chest leads 106.6cm/42 in, extended leads
121.9cm/48 in)
7-8 PageWriter TC70 Cardiograph Repair Manual
Page 9
Parts and Supplies Supplies and Ordering Information
Lead Accessories
Part Number Description
989803129231 Alligator Clips for Disposable Tab Electrodes (AAMI)
(10 total per pack)
989803129241 Alligator Clips for Disposable Tab Electrodes (IEC)
(10 total per pack)
989803101361 Alligator Clip Extender (Pediatric) for Disposable Tab
Electrodes (10 total per pack) (AAMI)
989803101371 Alligator Clip Extender (Pediatric) for Disposable Tab
Electrodes (10 total in pack) (IEC)
989803106061 Wide Disposable Tab Electrode Connector
(10 total per pack) (AAMI/IEC)
989803166031 Clear Tab with Snap Adapter (AAMI) (10 total
electrodes)
989803101701 IEC Snap Lead Adapter (converts IEC connector to
grabber connector for use with snap disposable electrodes and 4mm banana plug termination cables)
989803151701 16-Lead Spare Parts Kit (includes color rings, shorting
plugs, lead separators and banana post adapters)
Disposable and Reusable Electrodes
Part Number Description
989803100441 Solid gel tab disposable cardiography electrode, resting diagnostic
ECG (35 mm x 22 mm, 1.37 x .86 in) (1000 total electrodes)
989803106051 Solid gel tab disposable cardiography electrode, resting diagnostic
ECG (33 mm x 20 mm, 1.29 x .78 in) (1000 total electrodes)
989803149901 Pediatric disposable tab electrode (14 mm x 34 mm, .55 x 1.33 in)
(1000 total electrodes)
989803101311 Reusable Welsh Bulb Electrode 15 mm diameter (AAMI) (6 total
electrodes)
989803101651 Reusable Welsh Bulb Electrode 15 mm diameter (IEC) with banana
plug adapter (1 total electrode)
989803101281 Reusable Welsh Bulb Electrode (IEC) with side screw connection
(6 total electrodes) 989803101661 Reusable Adult Limb Plate Electrode (IEC) (4 total electrodes) 989803101691 Reusable Adult Limb Clamp Electrode (4 total electrodes)
(AAMI/IEC)
PageWriter TC70 Cardiograph Repair Manual 7-9
Page 10
Parts and Supplies Supplies and Ordering Information
Disposable and Reusable Electrodes
Part Number Description
989803101341 Reusable Adult Limb Plate Electrode for push-in type connection,
nickel-silver (4 total electrodes) (AAMI/IEC) 989803100601 Rubber Strap for Reusable Limb Plate Electrodes (38 cm/15 in)
(4 total straps) (AAMI/IEC)
Printer Paper
Part Number Description
989803106261 Z-fold, with header, A size (21.6 x 28 cm/8.5 x 11 in) 989803106271 Z-fold, with header, A4 size (21 x 29.69 cm/8.27 x 11.69 in) 989803106281 Anti-fade, A size (21.6 x 28 cm/8.5 x 11 in) 989803106291 Anti-fade, A4 size (21 x 29.69 cm/8.27 x 11.69 in)
Batteries
Part Number Description
989803160981 Lithium-ion replacement battery (2 battery operation only for
any cardiograph model)
989803170371 Lithium-ion replacement battery (1 battery operation for
PageWriter TC50/TC30 only, or for 2 battery operation for any cardiograph model)
Keyboard Covers
Part Number Description
989803166511 PageWriter TC70 Cardiograph Keyboard Cover (5 per pack) 989803166501 PageWriter TC50/TC30 Cardiograph Keyboard Cover (5 per
pack)
Replacement Fuse
Part Number Description
453564131221 PageWriter TC50/TC30 Cardiograph 1.6 amp (250 V)
Replacement Fuse
7-10 PageWriter TC70 Cardiograph Repair Manual
Page 11
Parts and Supplies Ordering Options and Upgrades
USB Memory Stick
Part Number Description
989803145331 USB Memory Stick
Ordering Options and Upgrades
For more information on ordering any of the following cardiograph upgrades or options, please contact your Philips Sales Representative or your local distributor.
Table 7-4 Data Input Options
Option Number Description
H12 Barcode Reader H13 Magnetic Card Reader H14 Smart Card Reader
Table 7-5 Patient Interface Module (PIM) Options
Option Number Description
H21 12-Lead Patient Interface Module (PIM) (AAMI or IEC) H22 16-Lead Patient Interface Module (PIM) (AAMI or IEC)
Table 7-6 Software Upgrades
Option Number Description
D01 Orders support (order system connectivity) D07 Manual order entry support (user entered orders) D12 Last ECG and Interactive Query support (requires
TraceMaster ECG Management System) D21 Wireless LAN support (802.11b/g) D22 Wireless LAN support (802.11a, 802.11b/g) H11 Global Modem support
Table 7-7 Cardiograph Cart and Accessories
Option Number Description
B01 Partially Assembled Cardiograph Cart B02 Fully Assembled Cardiograph Cart (only available in USA)
PageWriter TC70 Cardiograph Repair Manual 7-11
Page 12
Parts and Supplies Contacting a Philips Response Center
Table 7-7 Cardiograph Cart and Accessories
Option Number Description
C01 TC70 Cardiograph Cart Drawer C02 TC50 /TC30 Cardiograph Additional Cart Storage Bin/TC70
Cardiograph Additional Wire Storage Bin C03 Patient Cable Arm
Table 7-8 Keyboard Cover
Option Number Description
H16 Keyboard Cover
Contacting a Philips Response Center
The Philips Response Center can assist with product troubleshooting and provide technical expertise to help with any issue with the PageWriter TC cardiographs or any of its accessories.
For more information on the Philips Response Center go to:
www.medical.philips.com/main/services/response_center
North America Response Centers
Country Telephone Number
Canada (800) 323 2280 Mexico 01 800 710 8128 Puerto Rico 1 787 754 6811 United States (800) 722 9377
South America Response Centers
Country Telephone Number
Argentina 54 11 4546 7698 Brazil 0800 701 7789 Chile 0800 22 3003 Columbia 01 8000 11 10 10 Peru 51 1 620 6440
7-12 PageWriter TC70 Cardiograph Repair Manual
Loading...