Philips SAA4981-V1, SAA4981T-V1 Datasheet

DATA SH EET
Preliminary specification Supersedes data of May 1994 File under Integrated Circuits, IC02
1995 Oct 05
INTEGRATED CIRCUITS
SAA4981
1995 Oct 05 2
Philips Semiconductors Preliminary specification
Monolithic integrated 16 : 9 compressor SAA4981
FEATURES
Fixed horizontal compression by a factor of4⁄3 for most video standards
Three fixed screen positions (left, centre and right)
5 MHz bandwidth
Bypass function
Inputs for luminance and chrominance of side panels
Standard video inputs and outputs (Y, (B−Y) and (R−Y))
Horizontal and vertical sync signals are not processed
Pre filters and post filters on chip.
GENERAL DESCRIPTION
The integrated 16 : 9 compressor is an IC which compresses the active part of a video line by a factor of
4
3
from, for example, 52 µsto39µs. This is necessary to display 4:3 video software on a 16 : 9 tube in the correct proportion. The capacitively coupled video inputs are Y, (BY) and (RY).
The synchronisation input HREF is a line frequency reference signal. The bandwidth of the IC is up to 5 MHz and the signal delay is realized with SC Line Memories (Switched Capacitors Line Memories). The output of the 16 : 9 compressor also has the format Y, (BY) and (RY) and provides the following two possibilities:
1. Bypass function (the input signal is not compressed)
2. Compressed video by a factor of
4
⁄3 with three different
fixed screen positions (left, centre and right). The luminance and chrominance of the side panels are determined by the external signals YSIDE, BYSIDE and RYSIDE.
The horizontal compression is a time discrete and amplitude continuous signal processing. This provides pre and post filters which are realized on-chip. The internal clock generation is achieved with a 54 MHz horizontal PLL which is synchronized to the positive edge of the HREF signal. The function of the IC is controlled by the three control signals CTRL1, CTRL2 and CTRL3.
QUICK REFERENCE DATA
Voltages for video signals are peak-to-peak values for 75% colour bars. All voltages are referenced to V
EEA=VEED
=0V.
ORDERING INFORMATION
SYMBOL PARAMETER MIN. TYP. MAX. UNIT
V
CCA
analog supply voltage 4.75 5.0 5.5 V
V
CCD
digital supply voltage 4.75 5.0 5.5 V
V
iY(p-p)
Y input voltage (peak-to-peak value) 0.32 0.45 V
V
iU(p-p)
(BY) input voltage (peak-to-peak value) 1.33 1.9 V
V
iV(p-p)
(RY) input voltage (peak-to-peak value) 1.05 1.5 V
V
iHREF
input HREF top pulse 3.0 6.5 V
V
oY(p-p)
YOUT output voltage (peak-to-peak value) 0.32 0.5 V
V
oU(p-p)
(BY)OUT output voltage (peak-to-peak value) 1.33 2.1 V
V
oV(p-p)
(RY)OUT output voltage (peak-to-peak value) 1.05 1.7 V
TYPE NUMBER
PACKAGE
NAME DESCRIPTION VERSION
SAA4981 DIP24 plastic dual in-line package; 24 leads (600 mil) SOT101-1 SAA4981T SO24 plastic small outline package; 24 leads; body width 7.5 mm SOT137-1
1995 Oct 05 3
Philips Semiconductors Preliminary specification
Monolithic integrated 16 : 9 compressor SAA4981
BLOCK DIAGRAM
handbook, full pagewidth
3
3
SC LINE MEMORY
SC LINE MEMORY
MUX
SC LINE
MEMORIES
6.7 MHz
LOW-PASS FILTER
5 MHz
LOW-PASS FILTER
CLAMP
MUX Y
SC LINE MEMORY
SC LINE MEMORY
MUX
SC LINE
MEMORIES
6.7 MHz
LOW-PASS FILTER
5 MHz
LOW-PASS FILTER
CLAMP
MUX BY
SC LINE MEMORY
SC LINE MEMORY
MUX
SC LINE
MEMORIES
6.7 MHz
LOW-PASS FILTER
5 MHz
LOW-PASS FILTER
HORIZONTAL SEPARATION
54 MHz
PLL
CLAMP
MUX RY
C1 C2 C3
C1 C2 C3
C1 C2 C3
YSIDE
BYSIDE
RYSIDE
CONTROLLER
CLAMP REFERENCE
TEST CTRL2
CTRL1 CTRL3
C
LMY
C
LMBY
C
LMRY
BGREF
CLAOUT
C1 C2 C3
YOUT
(B-Y)OUT
(R-Y)OUT
18
17
16
YIN
(B-Y)IN
(R-Y)IN
HREF
6
21
22
23
11 1 2 3 24 5 15 14 1310912
20 19 8 7 4
V
CCA
V
EEA
V
CCD
V
EED
SUB
SAA4981
MHA277
Fig.1 Block diagram.
1995 Oct 05 4
Philips Semiconductors Preliminary specification
Monolithic integrated 16 : 9 compressor SAA4981
PINNING
SYMBOL PIN DESCRIPTION
C
LMY
1 decoupling capacitor for Y
reference voltage
C
LMBY
2 decoupling capacitor for BY
reference voltage
C
LMRY
3 decoupling capacitor for RY
reference voltage SUB 4 substrate connection (see Fig.5) CLAOUT 5 internal clamping reference voltage
output HREF 6 horizontal reference input V
EED
7 ground for digital section
V
CCD
8 positive digital supply voltage CTRL1 9 control input 1 CTRL2 10 control input 2 CTRL3 11 control input 3 TEST 12 test mode activation RYSIDE 13 side panel input for RY BYSIDE 14 side panel input for BY YSIDE 15 side panel input for Y (RY)OUT 16 output signal for (RY) (BY)OUT 17 output signal for (BY) YOUT 18 output signal for Y V
EEA
19 ground for analog section
V
CCA
20 positive analog supply voltage (RY)IN 21 input signal for (RY) (BY)IN 22 input signal for (BY) YIN 23 input signal for Y BGREF 24 decoupling capacitor for internal
reference voltage
Fig.2 Pin configuration.
handbook, halfpage
SAA4981
MHA276
1 2 3 4 5 6 7 8
9 10 11 12
24 23 22 21 20 19 18 17 16 15 14 13
C
LMY
C
LMBY
C
LMRY
SUB
CLAOUT
HREF V
EED
V
CCD
CTRL1
CTRL3
CTRL2
TEST
BGREF YIN (B-Y)IN (R-Y)IN V
CCA
V
EEA
YOUT (BY)OUT (RY)OUT
BYSIDE
YSIDE
RYSIDE
1995 Oct 05 5
Philips Semiconductors Preliminary specification
Monolithic integrated 16 : 9 compressor SAA4981
FUNCTIONAL DESCRIPTION Applicable video standards
The integrated 16 : 9 compressor can be used for the following video standards; B, C, D, G, H, I, K, K1, L, M and N. standards D, I, K, K1 and L will show a reduced video bandwidth above 5 MHz.
Clamping circuit
The clamping circuits clamp the video input signals Y, (BY) and (RY) to the DC level of the clamp reference signal fed from the clamp reference circuit. This is necessary to ensure that the input signals are in the correct input voltage range for the 5 MHz low-pass filters and the SC line memories.
Internal pre filters
Before the signals are sampled in the time discrete and amplitude continuous area, low-pass filtering is necessary to avoid any aliasing. Even if the inputs have already been low-pass filtered further filtering is advantageous for the electromagnetic compatibility (EMC). The same transfer function is used for all three low-pass filters because of the same bandwidth for the luminance and chrominance signals (up to 5 MHz).
SC line memories
After the low-pass filters the input signals are fed to the SC line memories. The signals are sampled at a clock frequency of 13.5 MHz. One video line later the signals are read with a clock frequency of 18 MHz in the compression mode. The result of the different clock frequencies is a horizontal compression by a factor of
4
⁄3. The clocks and
the horizontal starting pulses for the SC line memories are fed from the controller.
Two line memories are required for each signal path because in the compression mode, in one video line the signals are sampled to the SC line memories with
13.5 MHz and one video line later the signals are read with 18 MHz. In the bypass mode, via the SC line memories, in one video line the signals are sampled with 13.5 MHz and one video line later the signals are read with 13.5 MHz. The SC line memories are suitable for signals with a bandwidth up to 5 MHz. With a multiplexer (MUX) behind the SC line memories, the sampled video signal is connected to the internal post filters.
Output multiplexer MUX Y, MUX (BY) and MUX (RY)
The output multiplexers are controlled via C1 and C2 fed from the controller. The multiplexers are used to connect one of the four input signals to the output and, also, enable fast switching.
The input signals of the multiplexers for one component [Y, (BY) or (RY)] are as follows:
The output signal of the post filter
The uncompressed signal after the input clamping
The clamping reference signal
The signal for the side panel determined by YSIDE,
BYSIDE and RYSIDE.
The horizontal separation circuit
The 54 MHz horizontal PLL is locked to the positive edge of the digital HREF signal, which is generated in the horizontal separation circuit. It is also possible to use the positive edge of the burst key of a sandcastle signal.
54 MHz horizontal PLL
The 13.5 MHz clock frequency for the sampling clock and the 18 MHz clock frequency for the reading clock are generated in the 54 MHz horizontal PLL. The 13.5 MHz clock and the 18 MHz clock are line locked.
Clamp reference
Reference voltages are generated In the clamp reference block. These DC signals are used in the clamping circuits as input signals for the output multiplexers and as reference voltages for the SC line memories.
Four external capacitors at the pins C
LMY
, C
LMBY
, C
LMRY
and BGREF respectively are necessary to provide smoothing for the reference voltages. A black level reference signal is available at CLAOUT.
1995 Oct 05 6
Philips Semiconductors Preliminary specification
Monolithic integrated 16 : 9 compressor SAA4981
Controller
The controller generates the clocks and the horizontal start signals for the SC line memories and, also, the control signals for the output multiplexers. The timing for the start reading signal for three different screen positions (left, centre and right) and the control signals for the multiplexers (C1 and C2) is fixed. For the uncompressed signals a bypass via the SC line memories and a bypass not via the SC line memories is available. When the signals do not pass the line memories, the frequency response is not affected by the si-function. The compression and bypass mode via the line memories is delayed by one line with respect to the bypass mode not via the line memory.
The 16 : 9 compressor is controlled via the control signals CTRL1, CTRL2 and CTRL3 (see Table 1). The test input must be LOW level.
Table 1 Functions of the control signals
Internal post filters
The output signals of the SC line memories have to be filtered with three 6.7 MHz low-pass filters to eliminate the high frequencies caused by the time discrete signal processing. The cut-off frequency of 6.7 MHz is necessary because, as a result of the
3
⁄4 compression factor, the
frequencies are shifted to a higher frequency band with the inverse compression factor (e.g. 5 MHz compression
6.67 MHz). Due to the common bandwidth requirements for all three outputs of the SC line memories the same transfer function for the filters can be used.
Remark: These filters do not provide an si-correction. This means that an input signal with a frequency of 5 MHz will be damped by 2.1 dB at the output if the signal passes an SC line memory.
CTRL1 CTRL2 CTRL3 FUNCTION
LOW LOW LOW bypass (through the line
memories)
LOW HIGH LOW compression, left position HIGH LOW LOW compression, centre position HIGH HIGH LOW compression, right position
LOW LOW HIGH bypass (not through the line
memories)
Signals for the side panels
The luminance and chrominance of the side panels is determined by the external signals YSIDE, BYSIDE and RYSIDE. This external generated side panel signal can be referenced to the internal black level reference signal via the output CLAOUT (pin 5).
Horizontal timing (see Fig.3)
The horizontal timing refers to the positive edge of the input HREF signal.
The following timing parameters are valid for a horizontal frequency of 15.625 kHz.
Input clamping typically starts at t
A
= 1.55 µs and ends at
tB= 3.78 µs.
Loading...
+ 14 hidden pages