Instruction manual Page 1~22 To obtain the best performance and ensure years of trouble free use, please read this instruction manual completely.
Arahan pengendalian Muka surat 23~44 Untuk mendapatkan prestasi yang tinggi dan mengelakkan masalah untuk jangka masa yang lama, sila baca arahan ini sepenuhnya.
INDOOR UNIT
RAS-X18CX
– 1 –
SAFETY PRECAUTION
Please read the “Safety Precaution” carefully before operating the unit to ensure correct usage of the unit.
Pay special attention to signs of “ Warning” and “ Caution”. The “Warning” section contains matters which, if not observed strictly, may cause death or serious injury. The “Caution” section contains matters which may result in serious consequences if not observed properly. Please observe all instructions strictly to ensure safety.
The sign indicate the following meanings.
!
!
Make sure to connect earth line.
Indicates the instructions that must be followed.
Please keep this manual after reading.
PRECAUTIONS DURING INSTALLATION
Do not reconstruct the unit. Water leakage, fault, short circuit or fire may occur if you reconstruct the unit by yourself.
!
WARNING
!
CAUTION
Please ask your sales agent or qualified technician for the installation of your unit. Water leakage, short circuit or fire may occur if you install the unit by yourself.
Please use earth line. Do not place the earth line near water or gas pipes, lightning-conductor, or the earth line of telephone. Improper installation of earth line may cause electric shock.
A circuit breaker should be installed depending on the mounting site of the unit. Without a circuit breaker, the danger of electric shock exists.
Do not install near location where there is flammable gas. The outdoor unit may catch fire if flammable gas leaks around it.
Please ensure smooth flow of water when installing the drain hose.
The sign in the figure indicates prohibition.
W
W
A R N
N G
A R N
N G
!
PRECAUTIONS DURING SHIFTING OR MAINTENANCE
Should abnormal situation arises (like burning smell), please stop operating the unit
!
I
and turn off the circuit breaker. Contact your agent. Fault, short circuit or fire may occur if you continue to operate the unit under abnormal situation.
Please contact your agent for maintenance. Improper self maintenance may cause electric shock and fire.
Please contact your agent if you need to remove and reinstall the unit. Electric shock or fire may occur if you remove and reinstall the unit yourself improperly.
If the supply cord is damaged, it must be replaced by the special cord obtainable at authorized service/parts centers.
PRECAUTIONS DURING OPERATION
Avoid an extended period of direct air flow for your health.
Do not insert a finger, a rod or other objects into the air outlet or inlet. As the fan is rotating at a high speed, it will cause injury. Before cleaning, be sure to stop the operation and turn the breaker OFF.
I
Do not use any conductor as fuse wire, this could cause fatal accident.
During thunder storm, disconnect and turn off the circuit breaker.
– 2 –
PRECAUTIONS DURING OPERATION
The product shall be operated under the manufacturer specification and not for any other intended use.
Do not attempt to operate the unit with wet hands, this could cause fatal
ENGLISH
accident.
When operating the unit with burning equipments, regularly ventilate the room to avoid oxygen insufficiency.
Do not direct the cool air coming out from the air-conditioner panel to face household heating apparatus as this may affect the working of apparatus such as the electric kettle, oven etc.
Please ensure that outdoor mounting frame is always stable, firm and without defect. If not, the outdoor unit may collapse and cause danger.
Do not splash or direct water to the body of the unit when cleaning it as this may cause short circuit.
Do not use any aerosol or hair sprays near the indoor unit. This chemical can adhere on heat exchanger fin and blocked the evaporation water flow
!
to drain pan. The water will drop on tangential fan and cause water splashing out from indoor unit.
C A U
Please switch off the unit and turn off the circuit breaker during cleaning, the high-speed fan inside the unit may cause danger.
T
I
O
Turn off the circuit breaker if the unit is not to be operated for a long period.
N
Do not climb on the outdoor unit or put objects on it.
Do not put water container (like vase) on the indoor unit to avoid water dripping into the unit. Dripping water will damage the insulator inside the unit and causes short-circuit.
Do not place plants directly under the air flow as it is bad for the plants.
When operating the unit with the door and windows opened, (the room humidity is always above 80%) and with the air deflector facing down or moving automatically for a long period of time, water will condense on the air deflector and drips down occasionally. This will wet your furniture. Therefore, do not operate under such condition for a long time.
If the amount of heat in the room is above the cooling or heating capability of the unit (for example: more people entering the room, using heating equipments and etc.), the preset room temperature cannot be achieved.
This appliance is not intended for use by young children or infirm persons unless they have been adequately supervised by a responsible person to ensure that they can use the appliance safely.
Young children should be supervised to ensure that they do not play with the appliance.
– 3 –
NAMES AND FUNCTIONS OF EACH PART
INDOOR UNIT
Air filter
To prevent dust from coming into the indoor unit. (Refer page 17)
Front panel
Indoor unit indicators
Light indicator showing the operating condition. (Refer page 5)
Horizontal deflector (Air Outlet)
(Refer page 12)
Vertical deflector
OUTDOOR UNIT
Remote controller
Send out operation signal to the indoor unit. So as to operate the whole unit. (Refer page 6)
Drain pipe
Condensed water drain to outside.
Connecting cord and insulation pipe for piping
Air inlet (Back and Left side)
Air outlet
MODEL NAME AND DIMENSIONS
MODEL
RAS-X18CX
RAC-X18CX
WIDTH (mm)
1030
750
– 4 –
HEIGHT (mm)
295
570
DEPTH (mm)
191
280
INDOOR UNIT INDICATORS
TEMPORARY
SWITCH
TEMPORARY
SWITCH
HITACHI
OPERATION INDICATOR
OPERATION LAMP
This lamp lights during operation.
TIMER LAMP
This lamp lights when the timer is working.
FILTER LAMP
When the device is operated for a total of about 200 hours, the FILTER lamp lights to indicate that it is time to clean the filter. The lamp goes out when the “ (AUTO SWING)” button is pressed while the device is on “STANDBY MODE”.
ENGLISH
This figure shows the opening condition of
front panel. Refer to page 16 in relation to how to open or close the front panel.
TEMPORARY SWITCH
Use this switch to start and stop when the remote controller does not work.
By pressing the temporary switch, the operation is done in automatic mode.
– 5 –
NAMES AND FUNCTIONS OF REMOTE CONTROL UNIT
REMOTE CONTROLLER
This controls the operation of the indoor unit. The range of control is about 7 meters. If indoor lighting is controlled electronically, the range of control may be shorter. This unit can be fixed on a wall using the fixture provided. Before fixing it, make sure the indoor unit can be controlled from the remote controller.
Transmission sign
The transmission sign blinks when a signal is sent.
Display
This indicates the room temperature selected, current time, timer status, function and intensity of circulation selected.
CIRCULATION button
Use this button to set air circulation in the room or start operation.
DEHUMIDIFYING button
Use this button to reduce humidity in the room or start operation.
COOLING button
Use this button to set cooling mode in the room or start operation.
RESET button
STOP button
Press this button to stop operation only.
SLEEP button
Use this button to set the sleep timer.
FAN SPEED selector
This determines the fan speed. Every time you press this button, the intensity of circulation will change from (AUTO) to (HI) to (MED) to (LOW).
AUTO SWING button
Controls the angle of the horizontal air deflector.
TEMPERATURE button
CIRCULATION / START
DEHUMIDIFY / START
COOLING / START
FAN
FAN SPEED LOW
MED HI
SLEEP TIMER
STOP
TIMER SELECTOR ON TIMER OFF TIMER
AUTO SWING
Use this button to raise or lower the temperature setting. (Keep pressed, and the value will change more quickly.)
OFF-TIMER button Select to turn OFF time.
ON-TIMER button Select to turn ON time.
Precautions for Use
Do not put the remote controller in the following places.
In direct sunlight.
In the vicinity of a heater.
Handle the remote controller carefully. Do not drop it on the floor, and protect it from water.
Once the outdoor unit stops, it will not restart for about 3 minutes (unless you turn the power switch off and on or unplug the power cord and plug it in again). This is to protect the device and does not indicate a failure.
– 6 –
COOLING OPERATION
Use the device for cooling when the outdoor temperature is 21-43°C. If indoor humidity is very high (over 80%), some dew may form on the air outlet grille of the indoor unit.
Press the button so that the display indicates
(COOL).
Cooling operation starts with a beep.
1
The cooling function does not start if the temperature setting is higher than the current room temperature (even though the
(OPERATION) lamp lights). The cooling function will start as soon as you set the temperature below the current room temperature.
ENGLISH
2
3
Set the desired FAN SPEED with the (the display indicates the setting).
(AUTO): The FAN SPEED is HI at first and varies to
MED or LOW automatically when the preset temperature has been reached.
(HI) : Economical as the room will become cool
quickly.
(MED) : Fan speed slow.
(LOW) : Fan speed slower.
Set the desired room temperature with the TEMPERATURE button (the display indicates the setting).
The range of 25-28°C is recommended as the room temperature for cooling. If the temperature setting is 27°C, the room temperature will be controlled at around 27°C.
The temperature setting and the actual room temperature may vary somehow depending on conditions.
(FAN SPEED) button
STOP
As the settings are stored in memory in the remote controller, you only
Press the
have to press the
(STOP) button to stop operation.
(COOLING) button next time.
– 7 –
DEHUMIDIFYING OPERATION
Use the device for dehumidifying when the room temperature is over 16°C. When it is under 15°C, the dehumidifying function will not work.
Press the button so that the display indicates
1
(DEHUMIDIFY). Dehumidifying operation starts with a beep. The FAN SPEED is set at LOW automatically. The FAN SPEED button does not work.
Set the desired room temperature with the TEMPERATURE button (the display indicates the setting).
2
STOP
As the settings are stored in memory in the remote controller, you
Press the (STOP) button to stop operation.
only have to press the
The range of 20-26˚C is recommended as the room temperature for dehumidifying.
(DEHUMIDIFY) button next time.
Dehumidifying Function
When the room temperature is higher than the temperature setting: The device will dehumidify the room, reducing the room temperature to the preset level. When the room temperature is lower than the temperature setting: Dehumidifying will be performed at the temperature setting slightly lower than the current room temperature, regardless of the temperature setting. The function will stop (the indoor unit will stop emitting air) as soon as the room temperature becomes lower than the setting temperature.
– 8 –
CIRCULATION OPERATION
1
2
3
STOP
Press the button so that the display indicates (CIRCULATION).
Circulating operation starts with a beep.
Press the FAN SPEED button and select the desired FAN SPEED (the display indicates your choice).
Press the temperature control button to set to the desired temperature.
Press the (STOP) button to stop operation.
As the settings are stored in memory in the remote controller,
you only have to press the
(CIRCULATION) button next time.
ENGLISH
Circulation Function
During circulation operation, compressor will not be running and there is no cooling operation with only
indoor fan running.
When the setting temperature is higher than room temperature, indoor fan will stop running.
9
HOW TO SET THE SLEEP TIMER
Press the (SLEEP) button, and the display changes as shown below.
Sleep timer
Sleep Timer: The device will continue working for the designated
SLEEP
number of hours and then turn off. Point the signal window of the remote controller toward the indoor unit, and press the SLEEP button. The timer information will be displayed on the remote controller. The TIMER lamp lights with a beep from the indoor unit. When the sleep timer has been set, the display indicates the turn-off time.
Explanation of the sleep timer
Mode
Indication
44 44
1 hour 2 hours 3 hours 7 hours
Sleep timer off
1
The device will control the FAN SPEED and room temperature automatically so as to be quiet and good for peoples health.
NOTE
You cannot set other timer during sleep timer operation.
After sleep timer time is up and when press sleep button again, the sleep timer
will be set as last setting.
Sleep timer effective only once.
10
HOW TO SET THE TIMER
ON Timer and OFF Timer are available.
OFF Timer Reservation
OFF TIME setting
Select the OFF TIME by pressing the (OFF) Button.
Setting time will change according to the below sequence
when you press the button.
1 hour interval
1 2 3 9 10 11 12
(CANCEL OFF TIMER)
Operation stop at setting time
ENGLISH
ON Timer Reservation
ON TIME setting
Select the ON TIMER by pressing the (ON)
Button.
Setting time will change according to the below
sequence.
1 hour interval
1 2 3 9 10 11 12
(CANCEL ON TIMER)
Operation will start for setting temperature at setting time (The starting time may different depend on the room temperature and set temperature).
– 11 –
ADJUSTING THE AIR DEFLECTORS
Adjustment of the conditioned air in the upward and
1
downward directions. According to “Dehumidifying” or “Cooling” operation, the horizontal air deflector is automatically set to the proper angle suitable for each operation. The deflector can be swing up and down and also set to the desired angle using the (AUTO SWING) button. (If the angle of the deflector is changed, it will not return to the auto­set position after operations start unless the operation mode is switched.)
If the (AUTO SWING) button is pressed once,
the horizontal air deflector swings up and down. If the button is pressed again, the deflector stops in its current position. Several seconds (about 6 seconds) may be required before the deflector starts to move.
In Cooling operation, do not keep the horizontal air
deflector swinging for a long time. Some dew may form on the horizontal air deflector and dew may drop.
Adjustment of the conditioned air to the left and
2
right.
Hold the vertical air deflector as shown in the figure and adjust the conditioned air to the left and right.
– 12 –
HOW TO EXCHANGE THE BATTERIES IN THE REMOTE CONTROLLER
When using the remote control, if there is no response from the air conditioner unit or the remote control has fading and dim displays, the batteries in the remote control device need to be removed and replaced with new ones
Remove the cover as shown in the figure and
1
take out the old batteries.
=
Install the new batteries.
2
The direction of the batteries should match the marks in the case.
!
CAUTION
1. Do not use new and old batteries, or different kinds of batteries together.
2. Take out the batteries when you do not use the remote controller for 2 or 3 months.
3. Use high quality and high performance AAA batteries to avoid short operating life and electrolyte leakages
ENGLISH
– 13 –
THE IDEAL WAYS OF OPERATION
Suitable Room Temperature Install curtain or blinds
!
Warning
Freezing temperature is bad for health and a waste of electric power.
Ventilation Effective Usage Of Timer
It is possible to reduce heat entering the room through windows.
!
Caution
Do not close the room for a long period of time. Occasionally open the door and windows to allow the entrance of fresh air.
Do Not Forget To Clean The Air Filter
Dusty air filter will reduce the air volume and the cooling efficiency. To prevent from wasting electric energy, please clean the filter every 2 weeks.
At night, please use the “OFF or ON timer operation mode”, together with your wake up time in the morning. This will enable you to enjoy a comfortable room temperature. Please use the timer effectively.
Please Adjust Suitable Temperature
For Baby And Children
Please pay attention to the room temperature and air flow direction when operating the unit for baby, children and old folks who have difficulty in movement.
– 14 –
Loading...
+ 30 hidden pages