Philips RAC-18C9, RAS-18C9 User Manual

SPLIT TYPE AIR CONDITIONER
INDOOR UNIT/OUTDOOR UNIT
MODEL
RAS-18C9/RAC-18C9
ENGLISH
OUTDOOR UNIT
RAC-18C9
Instruction manual Page 1~22 To obtain the best performance and ensure years of trouble free use, please read this instruction manual completely.
INDOOR UNIT
RAS-18C9
Arahan pengendalian Muka surat 23~44 Untuk mendapatkan prestasi yang tinggi dan mengelakkan masalah untuk jangka masa yang lama, sila baca arahan ini sepenuhnya.
– 1 –
SAFETY PRECAUTION
Please read the “Safety Precaution” carefully before operating the unit to ensure correct usage of the unit.
Pay special attention to signs of “ Warning” and “ Caution”. The “Warning” section contains matters which, if not observed strictly, may cause death or serious injury. The “Caution” section contains matters which may result in serious consequences if not observed properly. Please observe all instructions strictly to ensure safety.
The sign indicate the following meanings.
!
!
Make sure to connect earth line.
Indicates the instructions that must be followed.
Please keep this manual after reading.
PRECAUTIONS DURING INSTALLATION
Do not reconstruct the unit. Water leakage, fault, short circuit or fire may occur if you reconstruct the unit by yourself.
!
WARNING
!
CAUTION
Please ask your sales agent or qualified technician for the installation of your unit. Water leakage, short circuit or fire may occur if you install the unit by yourself.
Please use earth line. Do not place the earth line near water or gas pipes, lightning-conductor, or the earth line of telephone. Improper installation of earth line may cause electric shock.
A circuit breaker should be installed depending on the mounting site of the unit. Without a circuit breaker, the danger of electric shock exists.
Do not install near location where there is flammable gas. The outdoor unit may catch fire if flammable gas leaks around it.
Please ensure smooth flow of water when installing the drain hose.
The sign in the figure indicates prohibition.
W
A R N
N G
!
W
A R N
N
G
PRECAUTIONS DURING SHIFTING OR MAINTENANCE
Should abnormal situation arises (like burning smell), please stop operating the unit
!
I
and turn off the circuit breaker. Contact your agent. Fault, short circuit or fire may occur if you continue to operate the unit under abnormal situation.
Please contact your agent for maintenance. Improper self maintenance may cause electric shock and fire.
Please contact your agent if you need to remove and reinstall the unit. Electric shock or fire may occur if you remove and reinstall the unit yourself improperly.
PRECAUTIONS DURING OPERATION
Avoid an extended period of direct air flow for your health.
Do not insert a finger, a rod or other objects into the air outlet or inlet. As the fan is rotating at a high speed, it will cause injury. Before cleaning, be sure to stop the operation and turn the breaker OFF.
I
Do not use any conductor as fuse wire, this could cause fatal accident.
During thunder storm, disconnect and turn off the circuit breaker.
– 2 –
PRECAUTIONS DURING OPERATION
The product shall be operated under the manufacturer specification and not for any other intended use.
Do not attempt to operate the unit with wet hands, this could cause fatal accident.
When operating the unit with burning equipments, regularly ventilate the room to avoid oxygen insufficiency.
Do not direct the cool air coming out from the air-conditioner panel to face household heating apparatus as this may affect the working of apparatus such as the electric kettle, oven etc.
Please ensure that outdoor mounting frame is always stable, firm and without defect. If not, the outdoor unit may collapse and cause danger.
Do not splash or direct water to the body of the unit when cleaning it as this may cause short circuit.
ENGLISH
Do not use any aerosol or hair sprays near the indoor unit. This chemical can adhere on heat exchanger fin and blocked the evaporation water flow
!
to drain pan. The water will drop on tangential fan and cause water splashing out from indoor unit.
C A U
Please switch off the unit and turn off the circuit breaker during cleaning, the high-speed fan inside the unit may cause danger.
T
I
O
Turn off the circuit breaker if the unit is not to be operated for a long period.
N
Do not climb on the outdoor unit or put objects on it.
Do not put water container (like vase) on the indoor unit to avoid water dripping into the unit. Dripping water will damage the insulator inside the unit and causes short-circuit.
Do not place plants directly under the air flow as it is bad for the plants.
When operating the unit with the door and windows opened, (the room humidity is always above 80%) and with the air deflector facing down or moving automatically for a long period of time, water will condense on the air deflector and drips down occasionally. This will wet your furniture. Therefore, do not operate under such condition for a long time.
If the amount of heat in the room is above the cooling or heating capability of the unit (for example: more people entering the room, using heating equipments and etc.), the preset room temperature cannot be achieved.
This appliance is not intended for use by young children or infirm persons unless they have been adequately supervised by a responsible person to ensure that they can use the appliance safely.
Young children should be supervised to ensure that they do not play with the appliance.
– 3 –
NAMES AND FUNCTIONS OF EACH PART
INDOOR UNIT
Air filter
To prevent dust from coming into the indoor unit. (Refer page 17)
Front panel
Indoor unit indicators
Light indicator showing the operating condition. (Refer page 5)
Horizontal deflector (Air Outlet)
(Refer page 12)
Vertical deflector
OUTDOOR UNIT
Remote controller
Send out operation signal to the indoor unit. So as to operate the whole unit. (Refer page 6)
Drain pipe
Condensed water drain to outside.
Connecting cord and insulation pipe for piping
Air inlet (Back and Left side)
Air outlet
MODEL NAME AND DIMENSIONS
MODEL
RAS-18C9
RAC-18C9
WIDTH (mm)
1030
750
– 4 –
HEIGHT (mm)
295
570
DEPTH (mm)
190
280
INDOOR UNIT INDICATORS
OPERATION LAMP
This lamp lights during operation.
HITACHI
OPERATION INDICATOR
ENGLISH
TIMER LAMP
This lamp lights when the timer is working.
FILTER LAMP
When the device is operated for a total of about 200 hours, the FILTER lamp lights to indicate that it is time to clean the filter. The lamp goes out when the “ (AUTO SWING)” button is pressed while the device is on “STANDBY MODE”.
This figure shows the opening condition of
front panel. Refer to page 16 in relation to how to open or close the front panel.
AUTO RESTART SWITCH
AUTO
RESTART
SWITCH
AUTO RESTART SWITCH
In the event of power failure, the air conditioner will restart automatically in the previously selected mode once
the power is restored.
In the event of power failure during TIMER operation, the timer will be reset and the unit will begin or stop
operating under a new timer setting.
– 5 –
NAMES AND FUNCTIONS OF REMOTE CONTROL UNIT
This controls the operation function and timer setting of the room air conditioner. The range of control is about 4 meters. If indoor lighting is controlled electronically, the range of control may be shorter.
Precautions for Use
Do not put the remote controller in direct
sunlight and high temperature.
Do not drop it on the floor, and protect
it from water.
If you press the FUNCTION selector
button during operation, the air conditioner may stop for about 3 minutes for protection before you can start it again. (unless you turn off and on again the power source)
You can use the remote controller by fixing it on the wall with the accessory parts.
Before fixing it,
HOLDER
make sure the unit can be controlled by the remote control unit at the fixing
REMOTE CONTROLLER
position.
– 6 –
AUTOMATIC OPERATION
°C
The device will automatically determine the operation mode either COOL or DEHUMIDIFY, depending on the initial room temperature.
Press the (START/STOP) button
1
Operation start with a “beep.
Press the (START/STOP) button
STOP
Please make sure you have been selected the (Automatic) mode
by use the (FUNCTION) Button.
The fan speed selector does not work at this operation.
You can slightly adjust the room temperature.
Press the (ROOM TEMPERATURE) button
1
Temperature setting change by 1°C for each 1 time press.
°C
Up
Down
▲ ▲
ENGLISH
You can raise or lower the temperature setting by a maximum of
3°C.
The display does not indicate the preset temperature in the Automatic
mode. Device will receive the setting by a “beep”.
CONDITION OF AUTOMATIC OPERATION
The selected mode of operation will not change during the operation even though the room
temperature change.
INITIAL ROOM
TEMPERATURE (APPROX.)
-
Over 27°C COOL
-
16 ~ 27°C
FUNCTION
DEHUMIDIFY
TEMPERATURE
SETTING
27°C
Slightly lower than the room temperature
FAN SPEED
HIGH at start, MEDIUM or LOW after the preset temperature is reached
LOW
– 7 –
CIRCULATION OPERATION
When the room temperature is higher than the thermostat set temperature, only the fan operates to circulate the upper hotter air downwards. This makes temperature distribution of the room evenly at heating.
Press the (START/STOP) button
1
Operation start with a signal received sound “beep.
Press the (START/STOP) button
STOP
Make sure you have been select the (Circulate) mode by using
the (FUNCTION) Button.
You can select the fan speed and desired temperature.
This operation is useful in winter when using other heating equipment.
HOW TO SET THE SLEEP TIMER
Mode
44 44
Sleep timer
Sleep Timer: The device will continue working for the designated number of hours and then turn off. Point the signal window of the remote controller toward the indoor unit, and press the SLEEP button. The timer information will be displayed on the remote controller. The TIMER lamp lights with a beep from the indoor unit.
Example: Setting 3 hours sleep time.
1 hour 2 hours 3 hours 7 hours
How to Cancel Reservation
Point the signal window of the remote controller toward the indoor unit, and press the (CANCEL) button. The (RESERVED) sign goes out with a beep and the (TIMER) lamp turns off on the indoor unit.
Indication
Sleep timer off
1
NOTE
If you set the sleep timer when the off-timer or on/off-timer has been set earlier, the sleep timer becomes effective instead of the off- or on/off­timer set earlier.
– 8 –
Explanation of the sleep timer
The device will control the FAN SPEED and room temperature automatically so as to be quiet and good for peoples health. You can set the sleep timer to turn off after 1, 2, 3 or 7 hours. The FAN SPEED and room temperature will be controlled as shown below.
Operation with the sleep timer
Function Operation
ENGLISH
Cooling
and
dehumidifying
controlled 2°C above the temperature and the FAN SPEED will be set to LOW setting 1 hour after the setting of the sleep timer.
Sleep timer set
1 hour
2 hours later
6 hours later
7 hours later
3 hours later
Fan
The settings of room temperature and circulation are varied.
NOTE
If date or current time is not set, sleep timer can not be set.
If you set the sleep timer after the off-, on/off- or off/on-timer has been set, the sleep timer
becomes effective instead of the off-, on/off- or off/on-timer set.
You can not set other timer during sleep timer operation.
The room temperature will be
– 9 –
MANUAL OPERATION [Cooling ● Dehumidify ● Circulation]
Please use under below condition when you want to set the function mode, room temperature and fan speed by manually.
DEHUMIDIFYING
Room Temperature 16°C above
OPERATION MODE SELECTION
1
Every time you press the button, the mode will change as the below
sequence
(Auto) [ (Cool) [ (Dehumidify) [ (Circulation)
ROOM TEMPERATURE SETTING
2
Recommend Temperature
°C
The cooling operation does not start if the
temperature setting is higher than the current room temperature.
FAN SPEED SETTING
3
Up
▲ ▲
Down
Dehumidify 16~26°C
Cooling 25~28°C
Outdoor Temperature 22-42°C
COOLING
Every time you press the button, fan speed will change as the below sequence.
COOLING
CIRCULATION
NOTE
(Auto) : The FAN SPEED is HIGH at first and varies to MED or LOW
automatically when the preset temperature has been reached.
DEHUMIDIFYING : LOW (FIXED)
Dehumidify Function
When the room temperature is higher than the temperature setting: The device will dehumidify the room, reducing the room temperature to the preset level. When the room temperature is lower than the temperature setting: Dehumidifying will be performed with the room temperature set slightly lower than the current room temperature, whatever the temperature setting. The function will stop (the indoor unit will stop emitting air) as soon as the room temperature becomes lower than the setting.
Press the (START/STOP) button
4
Operation start with a signal received sound beep”.
: AUTO [ HIGH [ MED [ LOW
}
: ( [ [ [ )
: ( )
Press the (START/STOP) button
STOP
As the settings are stored in memory in the remote control unit, you
only have to press the (Start/Stop) button next time.
– 10 –
TIMER RESERVATION
ON Timer and OFF Timer are available.
OFF Timer Reservation
OFF TIME setting
1
Select the OFF TIME by pressing the (OFF)
Button.
Setting time will change according to the below
sequence when you press the button.
0.5 hour interval 1 hour interval
0.5 1.0 1.5 9.5 10 11 12
The value change quicker if you keep pressing the
button.
Press the (Reserve) button
2
OFF TIMER reserved with a signal received sound
beep”.
The (OFF) Mark starts lighting instead of blinking.
ON Timer Reservation
o
Operation stop at setting time
ENGLISH
ON TIME setting
1
Select the ON TIMER by pressing the (ON)
Button.
At the beginning of setting, time 6 hours was set.
Setting time will change according to the below
sequence.
0.5 hour interval 1 hour interval
0.5 1.0 1.5 9.5 10 11 12
The value change quicker if you keep pressing the
button.
Press the (Reserve) button
2
ON TIMER reserved with a signal received sound
beep”.
The (ON) Mark starts lighting instead of blinking.
CANCELLATION of Timer Reservation
Operation will start for setting temperature at setting time (The starting time may different depend on the room temperature and set temperature).
Press the (Cancel) button
1
As the time settings are stored in remote controller
memory, you only have to press the (Reserve) button in order to use the same setting next time.
– 11 –
ADJUSTING THE AIR DEFLECTORS
1
Adjustment of the conditioned air in the upward and downward directions. According to Dehumidifying or Cooling operation, the horizontal air deflector is automatically set to the proper angle suitable for each operation. The deflector can be swung up and down and also set to the desired angle using the (AUTO SWING) button. (If the angle of the deflector is changed, it will not return to the auto-set position after operations start unless the operation mode is switched.)
If the (AUTO SWING) button is pressed
once, the horizontal air deflector swings up and down. If the button is pressed again, the deflector stops in its current position. Several seconds (about 6 seconds) may be required before the deflector starts to move.
In Cooling operation, do not keep the horizontal
air deflector swinging for a long time. Some dew may form on the horizontal air deflector and dew may drop.
2
Adjustment of the conditioned air to the left and right.
Hold the vertical air deflector as shown in the figure and adjust the conditioned air to the left and right.
– 12 –
HOW TO EXCHANGE THE BATTERIES IN THE REMOTE CONTROLLER
Remove the cover as shown in the figure and take out the
1
old batteries.
=
Install the new batteries.
2
The direction of the batteries should match the marks in the case.
!
CAUTION
1. Do not use new and old batteries, or different kinds of batteries together.
2. Take out the batteries when you do not use the remote controller for 2 or 3 months.
Push and pull to the direction of arrow
ENGLISH
– 13 –
THE IDEAL WAYS OF OPERATION
Suitable Room Temperature Install curtain or blinds
!
Warning
Freezing temperature is bad for health and a waste of electric power.
Ventilation Effective Usage Of Timer
It is possible to reduce heat entering the room through windows.
!
Caution
Do not close the room for a long period of time. Occasionally open the door and windows to allow the entrance of fresh air.
Do Not Forget To Clean The Air Filter
Dusty air filter will reduce the air volume and the cooling efficiency. To prevent from wasting electric energy, please clean the filter every 2 weeks.
At night, please use the OFF or ON timer operation mode, together with your wake up time in the morning. This will enable you to enjoy a comfortable room temperature. Please use the timer effectively.
Please Adjust Suitable Temperature
For Baby And Children
Please pay attention to the room temperature and air flow direction when operating the unit for baby, children and old folks who have difficulty in movement.
– 14 –
Loading...
+ 30 hidden pages