Philips PLUS T8 U-Bent User Manual

Philips PLUS T8 U-Bent Lamps featuring ALTO Lamp Technology
Ideal for applications requiring longer life
T8 COLLECTION
®
Extend your relamping cycles
Philips PLUS T8 U-Bent Lamps are environmentally­responsible lamps that offer long life and low mercury.
Long life
• PLUS 32W T8 U-Bent has the longest rated average life in the industry
• 25% longer life than standard 32W T8 U-Bent
• Warranty period: 30 months
Sustainable lighting solution
• Low mercury, which reduces the impact to the environment
• Long life for increased savings on maintenance and recycling costs
*
† This lamp is better for the environment because of
its reduced mercury content.All Philips ALTO lamps give you end-of-life options which can simplify and reduce your lamp disposal costs depending on your state and local regulations.
®
Ideal for locations already using 32W T8 lamps
* The PLUS 32WT8 has a rated average life of 30,000 hours compared to an industry standard
4' T8 32W U-Bent lamp with 24,000 hour s rated average life (12 hrs per start on an instant start ballast with 2800 lumens and 85 CRI)
Philips PLUS T8 U-Bent Lamps featuring ALTO®Lamp Technology
B
ASED ON 3 HOURS PER START
5
Instant Start Ballast Programmed Start Ballast
24,000
30,000
30,000
36,000
BASED ON 12 HOURS PER START
2
0 10,000 20,000 30,000 40,000
Rated Average Life in Hours
Ordering, Electrical and Technical Data
Product Ordering Pack. Temp. Length 12-hr on 12-hr on Initial Design Lumen Number Code Watts Qty. (Kelvin) (In.) Ins. Start
21977-4 FB32T8/TL830/PLUS/6/ALTO 32 20 3000 22 21978-2 FB32T8/TL835/PLUS/6/ALTO 32 20 3500 22 21983-2 FB32T8/TL841/PLUS/6/ALTO 32 20 4100 22 21987-3 FB32T8/TL850/PLUS/6/ALTO 32 20 5000 22
1) Rated average life is the length of operation (in hours) at which point an average of 50% of a large sample of lamps will still be operational and 50% will not.
2) Average life under engineering data with lamps turned off and restar ted once every 12 operating hours. Lamp life is appreciably longer if lamps are started less frequently.
3) Approximate initial lumens.The lamp lumen output is based upon lamp performance after 100 hours of operating life, when the output is measured dur ing operation on a reference ballast under standard laboratory conditions.For expected lamp lumen output, commercial ballast manufacturers can advise the appropriate ballast factor for each of their ballasts when they are informed of the designated lamp.The ballast factor is a multiplier applied to the designated lamp lumen output.
4) Design lumens are the approximate lamp lumen output at 40% of the lamp’s rated average life.This output is based upon measurements obtained during lamp operation on a reference ballast under standard laborator y conditions.
Color Nom. Rated Average Life (Hrs.)1Approx.
2
7
16 30,000 36,000 2800 2535 85 95%
7
16 30,000 36,000 2800 2535 85 95%
7
16 30,000 36,000 2800 2535 85 95%
7
16 30,000 36,000 2750 2500 84 95%
Prog.Start2Lumens3Lumens4CRI Maint.
Rated Average Life
Philips PLUS T8 U-Bent Lamps
5) Average life under specified test conditions with lamps turned off and restarted no more frequently than once ever y 3 operating hours. Lamp life is appreciably longer if lamps are started less frequently.
2) See above for footnote
© 2008 Philips Lighting Company. All rights reserved. Printed in USA 4/08
P-5937
www.philips.com
Philips Lighting Company 200 Franklin Square Drive P.O. Box 6800 Somerset, NJ 08875-6800 1-800-555-0050
A Division of Philips Electronics North America Corporation
Philips Lighting 281 Hillmount Road Markham, Ontario Canada L6C 2S3 1-800-555-0050
A Division of Philips Electronics Ltd.
Loading...