Page 1
ObstiVision
maintenance free LED obstacle light
lighting solutions that really last
lighting solutions that really last
Page 2
The MASTER Collection – Lighting solutions that make business sense.
Offering best in class energy efficiency, lifetime reliability and lighting quality, Philips
MASTER Collection lamps, luminaires and control gears minimise your lighting
solution’s total cost of ownership. You can start enjoying significant savings and benefits
from day one by replacing your conventional lighting products with Philips MASTER
Collection upgrades. You can achieve even more dramatic savings and improvements
by switching your whole lighting system to the Philips MASTER Collection.
Page 3
the new generation
Location of obstacle lights
N1
obstruction lighting system
Obstacle light to mark the presence of tall structures that may
present hazards to air navigation at night time is a legal
requirement. The lighting system must be designed to meet
International Civil Aviation Organisation
product specification and placement.
Traditionally obstacle light has used incandescent
technology. The short lifetime of the incandescent
lamps of approximately 1,000 hours and their
susceptibility to failure caused by vibration required
that the fitting have two lamps. This ensured that in
the event of one failure the other lamp could take
over. This system required constant and frequent
lamp changing, costly maintenance, and was high in
energy consumption.
Now, the benefits of the latest in Light Emitting
(LED) technology can provide a far superior
Diode
solution. By taking advantage of its long lifetime of
approximately 100,000 hours, low power consump-
tion, and resistance to shock and vibration of
the Philips ObstiVision provides an ideal, mainte-
nance free solution to obstruction lighting system.
The standards and requirements of obstacle light
Obstruction lighting systems must meet the
requirements of the
Aviation Organisation Standards and Recommended
Practices: Aerodromes- Annex 14- Volume 1, 3rd
Edition, July 1999, Chapter 6.
ICAO International Civil
(ICAO) standards for
The key points that must be adhered to are
• To reduce the hazards to the aircraft, obstacles
above the horizontal surface should be lighted to
indicate the presence of the obstacles
• The light must be fixed, and red in colour
• Minimum peak intensity at background
luminance of up to 500cd/m2: 10cd for low
intensity type A and 32cd for low intensity type B
• Vertical beam spread of not less than 10 degrees
• Minimum intensity (cd) at given elevation
angles when the light is levelled: +6 degrees:
10cd for low intensity type A and 32cd for low
intensity type B
• Minimum intensity (cd) at given elevation angles
LEDs,
when the light is levelled: +10 degrees: 10cd for
low intensity type A and 32cd for low
intensity type B
• In addition to specified values, lights shall have
sufficient intensity to ensure conspicuity at
elevation angles between +/
50 degrees
ObstiVision in practice
ObstiVision is a dedicated maintenance-free
obstacle light for aviation warning purposes. Light
emitting diode
the light source of this product. ObstiVision is
suitable to be used as a Low Intensity, Type A and
Type B obstacle lights according to
Typical applications for Obstivison would include
telecommunication towers, tall buildings, airport
areas and power transmission towers.
(LED) technology is chosen to be
Number of lights = N =
-
0 degrees and
ICAO standard.
X
Y
Light spacing = X =
N2
Y (metres)
—————
45
Y
——– ≤ 45 m
N
The guidelines for the type and location of
obstacle lights are contained within the
standard as described.
ICAO
Page 4
The benefi ts of LED technology
LEDs are a time tested solid state technology that emits a single colour of
light when an electric current is applied. They are revolutionising the lighting
world. Numerous benefi ts of this technology include extreme long life,
reliability and exceptional energy effi ciency. Compared to a standard
incandescent solution the benefi ts in energy consumption and maintenance of
using the ObstiVision
LED solution are clear:
Benefi t Comparison
Lamp
Power consumption per luminaire (for Type A)
Lamp average life (hours)
Lamp life warranty
ICAO standard met
IP protection against dust and water
Operating voltage
Weight
Wind load at 200 km/h
Operating temperature
Light Intensity (
Colour
Vibration resistance
Supply voltage affect on light output
ICAO low intensity type A)
Typical Incandescent type Philips ObstiVision low intensity type A
Incandescent or special incandescent
100w (200W twin type)
4000 hours (50% burnt out)
Not available
Ye s
Typically
IP55
220-240Vac 50 Hz
5.0-7.5 kg
Higher than 40N
-55 to +55 degrees Celsius
>10 cd for Type A, >32 cd for Type B
Aviation Red
Susceptible to failure due to shock and vibration
Intensity varies with voltage fl uctuation
(ICAO)
Save time, money and hassle with ObstiVision
The effi ciency, reliability and freedom from maintenance that characterise
ObstiVision will save you money over time! Considering the cost of
ownership, you can have your payback period as short as 1 year by using
ObstiVision as compared to the conventional obstruction lighting system.
High intensity light emitting diode
Max 7W
100,000 hours
5 years
Ye s
IP65 (dust tight and jet proof)
210-250Vac constant light output or 24Vdc/48Vdc
<1.0 kg
Less than 40N
-40 to +70 degrees Celsius
>10 cd for Type A, >32 cd for Type B
Aviation Red
Resistant to shock and vibration
Stable with constant current generator (210-250V)
(ICAO)
(LED)
Page 5
product details
Technical descriptions
Mechanical
• Yellow powder painted high pressure die-cast aluminium housing
• UV-protected clear glass cover – 5mm thick
• Stainless steel plate to support
• Operating temperature =
•
IP65
• Wind load at 200 km/hr of less than 40 Newton force
• Threaded base for 1 inch in diameter size of pipe
(other size can be applied with the reducer or enlarger)
Electrical
• Standard type using nominal operating voltage of 48Vdc or
220-240Vac; 24 Vdc systems are available upon request
• Terminal block for 2 x 1.5mm
• Power consumption: 5W for 48Vdc Type A version, 7W for
220-240Vac Type A version and 12W for 48Vdc Type B version
• Constant current 100mA for Type A, 250mA for Type B
• Surge protection device integrated: according to Institute of
Electrical and Electronics Engineers
LED unit
-
40° C to +70° C
2
cables
(IEEE) requirement
Optical
• Luminous intensity of greater than 10 cd for low intensity
type A obstacle light and greater than 32 cd for low intensity
type B obstacle light
• Horizontal radiation coverage 360°
• Vertical radiation coverage 50°
• Color: aviation red, choice of fixed or flashed light
Installation
• Pipe installation: the standard luminaire comes with threaded
base – ready to be installed with threaded pipe of 1 inch in
diameter (other size of pipe – use standard reducer or enlarger)
• To attach ObstiVision with existing antenna / pipe or
wall-mounted installation, the mounting kit is required.
Accessories
• Control box *
• Photo switch and sensor
• Mounting accessories *
• 3-way and 4-way junction box for through-wiring
• Solar cell
Product compliances
• Product compliance with International Civil Aviation Organization
(ICAO) standards and recommended practices – Aerodromes
Annex 14 Volume 1, 3rd edition – July 1999, Chapter 6.
• Federal Aviation Administration
* please check with your local Philips agent for details
Specifi cations subject to modifi cation
All intellectual property rights reserved,
Koninklijke Philips Electronics N.V.
(FAA) standard
Dimensional Sketches
240
dimensions in mm
96 66
Ordering Data
Product Code
XGP388 48Vdc A
XGP388 220-240Vac
50-60Hz A/AF
XGP388 48Vdc B
ZGB388 220-240Vac
50-60Hz / 48Vdc L P
ZBG388 220-240Vac
50-60Hz / 48Vdc L T
ZGP388 TW3
ZGP388 TW4
ZPP388
ZVB388
ZWB388
ZGL388 P
Description
ObstiVision 48Vdc Type A
ObstiVision 220-240Vac 50-60Hz Type A
(fl asher selector is integrated)
ObstiVision 48Vdc Type B
Control Box 220-240Vac 50-60Hz input
48Vdc output with photo switch
ontrol Box 220-240Vac 50-60Hz input
48Vdc output with timer
3-way throughwiring junction box
4-way throughwiring junction box
Mounting Kit - pipe installation
Mounting Kit - building top installation
Mounting Kit - wall mounted installation
Photo sensor
Ø 113
G1”
Ordering Number
9199 186 76132
9199 186 77132
9199 186 76532
9199 186 72732
9199 186 72232
9199 186 71032
9199 186 71132
9199 186 70032
9199 186 70132
9199 186 70232
9199 186 70332
DESIGNED BY PHILIPS DESIGN HONG KONG 2003
Page 6
Hong Kong – Philips Electronics
Hong Kong Ltd.
Lighting Asia Pacific Headquarters
27th Floor, Hopewell Centre
1 7 Kennedy Road, Wanchai, Hong Kong
Tel: + 852 2821 5300
Fax: + 852 2821 5342
E-mail: ltinfo.hongkong@philips.com
Australia – Philips Lighting
Level 1 , Philips House
65 Epping Road, North Ryde
NSW 211 3, Sydney, Australia
Tel: + 61 2 9947 0000 or
1 300 304 404 (toll free - local only)
Fax: + 61 2 9947 0325
E-mail: ltinfo.australia@philips.com
China – Philips Lighting
No. 1 805 Hu Yi Road, Malu Town
Jiading District, Shanghai, 201 801, P.R.China
Tel: + 86 21 591 5 4060
Fax: + 86 21 591 5 4064
E-mail: ltinfo.china@philips.com
India – Philips Lighting
Lighting Division
Motorola Excellence Centre, 5th Floor
41 5/2 Mehrauli-Gurgaon Road
Sector -1 4, Haryana-1 22001, India
Tel: + 91 1 24 509 1 900
Fax: + 91 1 24 509 1 91 2
E-mail: ltinfo.india@philips.com
Indonesia – Philips Lighting
Gedung Philips
J1 . Buncit Raya Kav. 99 -1 00
Jakarta 1 251 0, Indonesia
Tel: + 62 31 8491 674 or
0800 1 0 52678 (hotline - local only)
Fax: + 62 31 8473 240
E-mail: ltinfo.indonesia@philips.com
Japan – Philips Lighting
Philips Building
1 3-37, Kohnan 2-chome
Minato-ku, Tokyo 108-8507, Japan
Tel: + 81 3 3740 51 56
Fax: + 81 3 374 0 51 63
E-mail: ltinfo.japan@philips.com
Korea – Philips Lighting
260-1 99 Itaewon-dong
Yongsan-ku, Seoul 1 40-200, Korea
Tel: + 82 2 709 1 31 2
Fax: + 82 2 709 1 350
E-mail: ltinfo.korea@philips.com
32 2 B21 3 001-01
Malaysia – Philips Lighting
76, Jalan Universiti
46200 Petaling Jaya
Selangor Darul Ehsan, Malaysia
Tel: + 60 3 7957 5511
Fax: + 60 3 7955 2739
E-mail: ltinfo.malaysia@philips.com
New Zealand – Philips Lighting
2 Wagener Place, Mt Albert
PO Box 1 041 , Auckland, New Zealand
Tel: + 64 9 81 5 4000 or
0800 454 448 (toll free - local only)
Fax: + 64 9 849 781 2 or
0800 1 60 875 (toll free - local only)
E-mail: ltinfo.newzealand@philips.com
Pakistan – Philips Lighting
F-54, S.I.T.E.
Karachi-75730, Pakistan
Tel: + 92 21 256 0071
Fax: + 92 21 257 8920
E-mail: ltinfo.pakistan_2@philips.com
Philippines – Philips Lighting
Philips House
106 Valero St. Salcedo Village
1227 Makati City, Philippines
Tel: + 63 2 845 7840
Fax: + 63 2 81 6 6340
E-mail: ltinfo.philippines@philips.com
Singapore – Philips Lighting
620A Lorong 1 Toa Payoh
Singapore 31 9762, Singapore
Tel: + 65 6882 3530
Fax: + 65 6253 2343
E-mail: ltinfo.singapore@philips.com
Taiwan – Philips Lighting
25B, No.66, Chung Hsiao W. Road
Sec. 1 , Taipei, Taiwan
Tel: + 886 2 2382 7666 or
0800 231 099 (toll free - local only)
Fax: + 886 2 2382 4422
E-mail: ltinfo.taiwan@philips.com
Thailand – Philips Lighting
51 5 Moo 4, Pattana 3 Road
Bangpoo Industrial Estate, Soi 8B
Preaksa, Samutprakarn 1 0280, Thailand
Tel: + 66 2 709 3300
Fax: + 66 2 740 4960-1
E-mail: ltinfo.thailand@philips.com
Vietnam – Philips Lighting
99-1 01 Ham Nghi Street
Ward: Nguyen Thai Binh
District 1 , Ho Chi Minh City, Vietnam
Tel: + 84 8 914 2248 Ex.304
Fax: + 84 8 91 4 2249
E-mail: ltinfo.vietnam@philips.com
www.lighting.philips.com/apr
© 2003 Koninklijke Philips Electronics N.V.
All rights reserved, reproduction in whole or in part without permission is prohibited.