LVLW
8.67"
(22.02 cm)
7.6 6"
(19.46 cm)
3.72"
(9.45 cm)
Features
is provided by two high-
performance 5.5 W, 6 VDC
MR16-style halogen lamps.
Lamps are held in an attractive
molded swivel assembly, and
are fully adjustable.
Housing: The high-abuse
housing, backplate and
electronics shell are molded
from high-impact, F1 rated,
GE Lexan
injection molded components
meet the UL 94 V-0, 5 VA
flame retardant standard for
emergency lighting products.
All units are supplied standard
with a UL damp location
listing and tamperproof screw
kit. Optional wet location
listed products include a fully
gasketed cover. Installation
is simplified by the use of a
snap-together backplate and
housing. When installed with
the supplied tamperproof
screw kit, removal from
mounting surface, or removal
of outer protective cover is
not possible under normal
service conditions without the
use of a torx T-15 bit. Utility
supply is completed by use of a
modular plug-in wiring harness.
A convenient knockout is
also made available in the top
right section of product to
accommodate 1/2” conduit
(damp location listed units
only).
®
polycarbonate. All
Operating Temperature
Range: Damp location
50°F (10°C) to 104°F (40°C)
Wet location
41°F (5°C) to 104°F (40°C)
Wet location with heater
-4°F (-20°C) to 104°F (40°C)
Electronics: 120/277 VAC
dual voltage input with surge-
protected, solid-state, fully
automatic, voltage regulated
charger. Charging system is
complete with low voltage
disconnect, AC lockout,
brownout protection and
combination indicator lamp and
illuminated test switch.
Electrical Specifications:
0
.05 A (120 VAC)
0.30 A (120 VAC) with heater
option
0.02 A (277 VAC)
0.13 A (277 VAC) with heater
option
Job Information Type:
Job Name:
Cat. No.:
Notes:
Battery
Maintenance free, sealed
lead calcium battery has an
expected service life of 5
years. Upon utility power
failure or brownout, the unit
shall automatically provide
emergency battery power and
maintain the stated illumination
level and output wattage for a
minimum period of 90 minutes.
Code Compliance
UL 924, UL damp location,
nd optional UL wet location
a
listed. NFPA 101, NEC, BOCA,
OSHA and IBC illumination
standards. Meets ADA
specifications for wall mounted
lighting fixtures.
Warranty
Three year full electronics
w
arranty. One year full plus
four year prorated lead calcium
battery warranty.
VANDAL-RESISTANT WET/DAMP LOCATION LIGHTING
Ordering Information
LV
Series
LV = LVL Series Damp/Wet Location Emergency Light
Accessories (order as a separate item) T15TPTOOL = Tamperproof Screwdriver
Optics
L
Battery
L = Lead Calcium
Housing Color
W = White B = Black BZ = Bronze
LVL Series
Page 2 of 2
Location Listing
Blank = Damp Location Listed WL = Wet Location Listed HR = Wet Location Listed with B attery Heater
0.35
0.31
0.36
0.41
0.28
0.31
0.33
0.90
0.26
0.24
0.17
0.14
0.13
0.11
1.04
1.56
3.82
1.58
1.33
3.55
3.40
0.72
2.83
9' 9'
0.31
0.36
0.35
1.86
0.57
0.41
1.96
0.52
Philips Lightolier e: lol.webmaster@philips.com t: (508) 679-8131 w: www.lightolier.com
LVL Series September 17, 2012
Specifications are subject to change without notice. © Koninklijke Philips Electronics N.V., 2012. All rights reserved.
0.28
1'
0.31
2'
0.33
3'
Chart represents (2) luminaires mounted on 18’ centers, mounting height 8’ AFF
Average initial footcandles at floor = 1.03 Minimum initial footcandles at floor = 0.28 Maximum initial footcandles at floor = 3.82 Maximum to minimum r atio = 13.7:1
* The optics layout shown is intended to be used as reference only. Standard ref lectances used were 80/50/20. Lightolier is not responsible for site specific conditions that may alter the results.
0.14
0.26
0.20
0.18
0.16
0.13
0.11
0.90
0.24
0.17
Job Information Type:
1.33
0.72
1.58
3.55
2.83
1.56
3.82
3.40
1.04
1.86
1.96
0.57
0.52
Loading...