Genion_ii_00111.qxd 7/4/02 11:39 AM Page 2

IMPORTANT SAFETY INSTRUCTIONS

The lighting flash with arrowhead sysbol, within an equilateral triangle, is intended to alert the user to the presence of uninsulated "dangerous voltage" within the product's enclosure that may be of sufficient magnitude to constitute a risk to persons.

The exclamation point, within an equilateral triangle, is intended to alert the user to the presence of important operating and maintenance accompanying the appliance.

1.Read these instructions

2.Keep these instructions.

3.Heed all Warnings.

4.Follow all instructions.

5.Do not use the apparatus near water.

6.Clean with a dry cloth only.

7.Do not install near heat sources such as radiators, heat registers, stoves, or other apparatus that generates heat (including amplifiers).

8.Do not defeat the purpose of a polarized or grounded mains plug. A polarized plug has dissimilar prongs (one wider than the other) to ensure correct polarity, while a grounded plug has an additional 'ground' prong provided for your safety. If the plug supplied with the apparatus does not fit into your outlet, consult an electrician for advice.

9.Protect the power-supply cord from being walked on or pinched, particularly close to plugs, receptacles and the point where it exits from the apparatus.

10.Only use attachments and accessories (including stands, tripods, mounting brackets and housings) specified or recommended by the manufacturer.

11.Unplug the apparatus during lightning storms and when unused for extended periods.

12.Do not attempt to service this unit yourself as opening or removing covers may expose you to dangerous voltage or other hazards. Refer all servicing to qualified service personnel.

13.Servicing is required when the apparatus does not function in the normal way, has been dropped, if liquid has been spilled on it, or if it has been exposed to rain or water. Unplug the unit from the outlet and refer servicing to qualified service personnel.

14.An all-pole mains switch with contact separation of at least 3 mm in each pole shall be incorporated in the electrical installation of the building.

Warning

To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture.

FCC Information

Caution: Any changes or modifications to construction of this device that are not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

Re-orient or relocate the receiving antenna.

Increase the separation between the equipment and receiver.

Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

Consult the dealer or an experienced radio/TV technician for help.

Genion_ii_00111.qxd 7/4/02 11:39 AM Page EN1

SPECIFICATIONS

 

LTC 0435/x0

LTC 0455/x0

 

Standard resolution

High resolution

Standard

PAL

NTSC

PAL

NTSC

Active pixels (H x V)

512 x 582

512 x 492

752 x 492

768 x 492

Imager

 

1/3" interline CCD

 

Resolution

330 TV lines

480 TV lines

Minimum illumination

<0.7 lux

<0.8 lux

 

 

 

<0.3 lux with Nightsense™

Signal-to-noise ratio

 

> 50 dB

 

Video output

 

1 Vpp, 75

 

Y/C output

NA

 

Y: 1 Vpp, 75 ;

 

 

 

C: 0.3 Vpp 75

Synchronization

Internal or Line-Lock (selectable)

 

Shutter

Auto / Flickerless / Off (selectable)

 

PAL: 1/50 - 1/125000 - NTSC: 1/60 - 1/150000

Nightsense™

NA

 

Auto / Forced / Off (selectable)

Autoblack

 

On / Off (selectable)

 

AGC

On (0-21 dB)/ Off (0 dB) (selectable)

BLC

 

On / Off (selectable)

 

ATW

Auto/Hold selectable 2500 to 9000 K

Lens mount

 

C and CS compatible

 

ALC

Video-iris or DC-iris (auto detect)

Power supply

LTC 04x5/10 & /20: 12 to 28 VAC or 11 to 36 VDC

 

LTC 04x5/50 & /60: 85 to 265 VAC

Power consumption

 

<4 W

 

Dimensions (HxWxL)

58 x 66 x 122 mm (2.28 x 2.6 x 4.8 inch without lens)

Weight

450 g (0.99 lbs) (without lens)

 

Camera mount

Two 1/4" 20 UNC - isolated (bottom) and

 

 

non-isolated (top)

 

Operating temperature

-20°C to +50°C (-4°F to +122°F)

Controls

On-screen display (OSD) with softkey controls

English

Type number overview

 

Low voltage

High voltage

 

PAL (Europe)

NTSC (USA)

PAL (Europe)

NTSC (USA)

Standard resolution

LTC 0435/10

LTC 0435/20

LTC 0435/50

LTC 0435/60

High resolution

LTC 0455/10

LTC 0455/20

LTC 0455/50

LTC 0455/60

EN1

Philips LTC 0435, LTC 0455 installation Guide

Genion_ii_00111.qxd 7/4/02 11:39 AM Page EN2

English

UNPACKING

Unpack carefully and handle the equipment with care. The packaging contains:

Camera

CCD protection cap

Spare lens connector (male)

These Instructions

Note: If equipment appears to have been damaged during shipment, repack it in the original packaging and notify the shipping agent or supplier.

CONNECTION

Power

LTC 04x5/10 and /20

LTC 04x5/50 and /60

To open the quick-connect, push in on the tabs. Connections are not polarity sensitive

Use stranded or solid wire AWG16 to AWG22, cut back 10mm (0.4") of insulation.