Philips HX7562 BROCHURE

elite®
e7000
the sonic toothbrush
series
A
B
C
J
D
E
F
G
I
ENGLISH 4
DEUTSCH 16
FRANÇAIS 29
NEDERLANDS 42
ESPAÑOL 55
ITALIANO 68
SONICARE ELITE 7000
ENGLISH4
General description
A Brush head B Colour code C Removable nut D Sonic power handle E Power on/off button F Dual Speed Control button (specific models only) G Charge indicator LEDs (specific models only) H Charger I Cord wrap facility J Luxury holder (specific models only)
Important
Read these instructions for use carefully before using the appliance and save them for future reference.
If you have any questions after reading this manual, please contact the Philips Customer Care Centre in your country or visit our website (www.philips.com).
Sonicare\ has been carefully engineered for both effectiveness and safety. However, basic safety precautions should always be followed when using any electrical product, especially when children are present.
Danger
To reduce the risk of electrocution:
1) Do not place or store the charger where it can fall or be pulled into a bathtub or washbasin.
2) Do not place or drop the charger into water or other liquid.
3) Do not reach for a charger that has fallen into water. Unplug immediately.
4) Do not use while bathing.
5) Do not plug the charger into a socket that supplies a voltage for which the charger is unsuitable. It has been designed for use with a specific electrical voltage.
6) Refer to the bottom of the charger for voltage specification.Voltage converters or plug adapters DO NOT guarantee voltage compatibility. Never force the plug into a socket.
Warning
To reduce the risk of burns, electrocution,fire or injury:
1) Close supervision is necessary when this product is used by or on children or the disabled.
2) Use this product only for its intended purpose as described in this booklet. Do not use attachments not recommended by the manufacturer. See voltage information above.
ENGLISH 5
3) Never operate the charger if it has a damaged cord or plug, if it is not working properly, if it has been dropped or if it has been dropped into water. For further instructions, contact your local Philips Customer Care Centre.
4) Keep the cord away from heated surfaces.
Medical warnings
1) Avoid using a brush head with crushed or bent bristles. Damaged bristles may break off while brushing. In order to prevent this, replace the brush head with a new one every 6 months or sooner if signs of wear appear.
2) Similar to starting with any new manual or electric oral hygiene product, consult your dental professional before using this appliance if you have had oral or gum surgery in the previous 2 months.
3) Contact your dental professional if excessive bleeding occurs after using this product or if bleeding continues to occur after 1 week of use.
4) If you have any questions concerning usage with a pacemaker or other implanted device, consult your physician or the implanted device manufacturer prior to use. Sonicare has been tested and is compliant with safety standards for electromagnetic devices.
5) The Sonicare toothbrush is a personal care appliance and is not intended for use on multiple patients in a dental office or institution.
6) This product is designed for cleaning teeth, gums and tongue only. Do not use it for any other purpose.
Preparing for use
To attach the Sonicare brush head:
1 Align the front of the brush head with the front of the
C
C
toothbrush handle. Match the bars on the brush head with the notches inside the top of the handle and slide the brush head onto the handle.
2 Turn the brush head nut clockwise until it is firmly tightened.
If the brush head rattles during use, tighten the nut further.
ENGLISH6
Charging the Sonicare\
Sonicare comes with the batteries completely discharged and should be charged for at least 24 hours during the first few days of use.
1 To charge your Sonicare,place the handle in the charger with
C
C
the Sonicare logo facing forward.Make sure the bottom of the handle sits back securely in the charger, making complete contact.
When the handle is placed incorrectly in the charger, the green
charge indicator LED will still light up, but charging will not take place.
Handles of other Sonicare models do not fit in this charger and will therefore not charge effectively. Do not attempt to force a handle into this charger as this will cause damage. It is recommended that you keep your Sonicare in the charger when not in use to maintain a full battery charge. It takes at least 24 hours to fully charge Sonicare's battery.
Using the appliance
Useful tips
You can use your favourite toothpaste with your Sonicare.The brush head comes with a convenient travel cap. Remove the
travel cap from the brush head before switching on your Sonicare.
Place the brush head in your mouth before switching on your
Sonicare, and be sure to switch it off before removing it from your mouth, otherwise toothpaste may splatter.
Rinse the brush head and bristles after each use.Clean the brush head weekly, including under the nut.A fully charged Sonicare will provide approximately 2 weeks of
typical use (2 minutes of brushing twice a day),making it easy to travel without the charger.
Remember: voltage converters and plug adapters DO NOT guarantee voltage compatibility. Always check for voltage compatibility.
Tips for specific oral care needs
Stain removal
In areas where staining occurs, a few seconds of additional brushing time may be spent to assist with stain removal.
Braces
C
The brush should be placed at a 45-degree angle between your brackets and gumline. While applying light pressure, gently move the bristles in a small circular motion so that the long bristles reach
ENGLISH 7
between your teeth for 2 seconds.Then gently turn (roll) the brush handle so the bristles clean the bracket and the rest of the tooth before you move the bristles to the next tooth. Continue this until you have brushed all of your teeth.
Dental restorations
Use the Sonicare on dental restorations (e.g. implants, caps, crowns, bridges and fillings) as you would on your normal tooth surfaces to reduce plaque build-up and improve gum health.Work the bristles around all areas of the restoration for thorough cleaning.
Periodontal pockets
Your dental professional may have indicated that you have periodontal pockets, deep pockets where plaque bacteria collect. If this is the case, after brushing for a full 2 minutes, spend extra time gently brushing these areas to improve your gum health.You may want to take advantage of the Programmable Quadpacer\ timer feature (see section 'Programmable Quadpacer timer').
Proper brushing technique
Follow these simple steps to maximise your brushing experience:
1 Before switching the Sonicare on,place the bristles of the
C
brush head on your gumline at a 45-degree angle.
2 Hold the handle with a light grip, switch the Sonicare on, and
glide the brush across your teeth.
3 To maximise Sonicare's effectiveness apply only light pressure
and let the Sonicare toothbrush do the brushing for you. Do not scrub.
4 The angled brush head and slender neck help you reach the
back teeth and the tooth surfaces on the inside of the mouth. Be sure to adjust your brushing to use the angle to your advantage and keep as many bristles in contact with the teeth as possible.
5 To make sure you brush evenly throughout the mouth,divide
C
your mouth into 4 sections: outside of upper teeth, inside of upper teeth, outside of lower teeth and inside of lower teeth. Begin brushing in section 1 (outside of upper teeth) and brush for 30 seconds before moving to section 2 (inside of upper teeth). Continue brushing the other two sections for 30 seconds until you have completed the 2-minute brushing cycle. If activated, the Programmable Quadpacer\ timer will beep every 30 seconds to signal you to move to the next quadrant.
ENGLISH8
6 After having completed the 2-minute brushing cycle, the
Sonicare will switch off automatically. If you want,you can switch the toothbrush back on for another brushing cycle and spend additional time brushing the chewing surfaces of your teeth.
7 You may also brush your tongue, with the toothbrush switched
on or off, as you prefer.
8 You may experience a slight tickling or tingling sensation after
using an electronic toothbrush such as the Sonicare for the first time.As you become accustomed to brushing with the Sonicare this sensation will diminish.
Special features
Features that simplify brushing:
Easy-start\ brushing power ramp-up
All Sonicare models come with the Easy-start feature activated,
which helps you get used to brushing with the Sonicare.
The brushing power will gently increase to full power over the
first 14 brushings.
The Easy-start feature is active if you hear 2 beeps immediately
after switching on your Sonicare. Once the appliance has reached optimal brushing power (after the 14th brushing), you will no longer hear the double beep at the beginning of the brushing cycle.
B
Note: Each of the first 14 brushings must be at least 1 minute in length to properly advance through the Easy-start ramp-up cycle.
To deativate or reactivate the Easy-start feature:
1 Attach the brush head to the handle.
2 Place the handle in the plugged-in charger.
3 To deactivate Easy-start:
Press and hold the on/off button for 2 seconds.You will hear 1 beep to indicate that the Easy-start feature has been deactivated.
4 To reactivate Easy-start:
Press and hold the on/off button until you hear 2 beeps.This indicates that the Easy-start feature is active again.
ENGLISH 9
Using the Easy-start feature beyond the initial ramp-up period is not recommended and reduces the effectiveness of the Sonicare in removing plaque.
The Easy-start feature should be deactivated when the Sonicare is used in clinical trials.
Smartimer\ 2-minute timer
All Sonicare models come with the Smartimer feature, which
automatically sets the brushing time to the 2 minutes recommended by dental professionals.After these 2 minutes, your Sonicare will automatically switch off.If you wish to brush for a longer period, simply press the on/off button and another 2-minute cycle will start.
If you wish to pause or stop brushing during your 2-minute cycle,
press the on/off button. If you press the on/off button again, the Smartimer will resume where you left off.
B
The Smartimer will automatically reset to the beginning of a 2-minute cycle if:
- brushing is paused for 30 seconds or longer;
- the handle is returned to the charger.
Quadpacer\ 30-second interval timer
The Quadpacer feature ensures that you brush all sections of
C
your mouth evenly and thoroughly.At 30-second intervals (at 30, 60 and 90 seconds in case of a 2-minute brushing cycle), you will hear a short beep and notice a brief pause in brushing action.This is your signal to move to the next section of your mouth.
Programmable Quadpacer timer (specific models only)
The Programmable Quadpacer timer allows you to customise the Quadpacer performance in 1 of 3 ways:
You may opt to keep the factory default setting of a 2-minute
brushing time with Programmable Quadpacer beeps activated.
You may choose to extend your brushing time to 2 1/2 minutes
by adding an additional 30-second interval.
You may choose a 2-minute brushing time,but with the
Quadpacer beeps deactivated.
To change the Programmable Quadpacer settings:
1 Place the handle in the charger that is plugged into a live
C
socket.
ENGLISH10
2 Press the Dual Speed Control button briefly and note which
LED lights up.
3 Press and hold the Dual Speed Control button.Continue to
hold the button while the LEDs slowly cycle through the timing interval setting options:
Green LED in position 4: Programmable Quadpacer active
C
C
C
(factory default setting).
Green LED in top (5th) position: 2 1/2 minute setting - the
Programmable Quadpacer active with an additional 30-second timing interval.
Yellow LED in bottom (1st) position: no timing intervals set - the
Quadpacer not active.
4 To program the desired setting, release the button when the
LED corresponding to your choice lights up.
B
Note: Selecting 2 1/2 minutes brushing time reduces the number of brushings available from a charged battery.
Dual Speed Control (specific models only)
The Dual Speed Control feature allows you to choose between 2 speed settings: Normal speed for optimal brushing performance, or Reduced speed when an even more gentle brushing action is desired.
Each time you switch your Sonicare on, it will begin brushing at the Normal speed setting.To change the speed setting:
1 From Normal to Reduced speed: press the Dual Speed Control
C
button once during brushing.
2 From Reduced to Normal speed: press the Dual Speed Control
button a second time during brushing.
A distinctive two-tone beep indicates that the speed setting has been changed.
It is recommended that you brush at the Normal speed setting to maintain optimal results.
ENGLISH 11
The Normal speed setting should be selected when the Sonicare is used in clinical trials.
Battery charge indicator (specific models only)
If the battery charge of your Sonicare is low, you will hear 3 beeps
C
after you have brushed your teeth for 2 minutes and the charge indicator LED will blink yellow for 30 seconds.
A low charge indication signifies that 3 or fewer 2-minute brushings remain. When not in use, keep the Sonicare in the charger to maintain a full battery charge.
Multiple-LED charge indicator (specific models only)
When the handle is placed in the charger, the green charge
indicator LEDs will blink in a rising pattern as the battery charges. The number of blinking LEDs indicates the level to which the battery has been charged.
When the battery reaches full charge, the LEDs stop blinking and start to burn continuously. About once a minute, the charge indicator LEDs go out momentarily and then go back on.This indicates that the battery is being maintained at full charge.The full charge indication will persist until the handle is removed from the charger. The blinking yellow LED indicates that fewer than 3 brushings remain.
Single-LED charge indicator (specific models only)
When the handle is placed in the charger, the charge indicator
C
LED will blink green as the battery charges.When the battery reaches full charge, the charge indicator LED will burn green continuously until the handle is removed from the charger.
When your Sonicare is switched on or off, the charge indicator LED will blink yellow if the battery charge is low.
Luxury brush holder (specific models only)
Some Sonicare models come with a luxury brush holder.
C
ENGLISH12
The luxury brush holder can be mounted to the wall with
C
C
C
2 screws (3.0 x 30 mm) and 2 wall plugs (not included)
Cleaning
Simple tips for care
By following these simple steps, you should get years of worry-free brushing:
1 Rinse the brush head and bristles after each use.
2 Clean the brush head weekly, including under the nut.
3 To remove the nut:
Press down gently on the grey seal area.
C
Avoid using sharp objects to push on the seal as this may cause damage.
Push the nut up over the end of the brush head.
C
4 To reassemble the nut,slip the nut over the brush head shaft
and insert the lower part of the brush head into the handle. Turn the nut clockwise until it is firmly tightened and the nut snaps into the seal.
ENGLISH 13
5 Clean the handle weekly.
C
6 Clean the charger periodically.
Unplug the charger before cleaning.
7 Examine the mains cord periodically. Do not use the charger if
the mains cord is damaged.
8 Use the cord wrap facility in the bottom of the charger to
store excess cord.
UNPLUG the charger before cleaning. After cleaning the charger completely dry the charger before connecting it to the mains.
Mild soap, water and a moist cloth are recommended for cleaning your Sonicare.
Replacement
Brush head
To maintain optimal brushing results, Sonicare brush heads should be replaced every 6 months or sooner if signs of wear appear.
Use only Sonicare Elite\ series replacement brush heads.
Environment
The handle contains a nickel cadmium battery.The battery must be recycled or disposed of in an environmentally safe way.
The battery inside your Sonicare cannot be replaced, but can be easily removed for recycling.At the end of product life and prior to disposal, please remove the battery from the handle by following the instructions below. Please note that this process is NOT reversible.
Do not throw the battery away with the normal household waste,
C
but hand it in at an official collection point.
For information about Sonicare's battery recycling programme or instructions on recycling your Sonicare, contact the Philips Customer Care Centre in your country.
Removing the battery
Caution should be exercised when using any household tools (such as a screwdriver) to remove the battery.
1 Deplete the battery of any charge by removing the handle from
the charger, switching the Sonicare on and allowing it to run
ENGLISH14
until it stops. Repeat this step until the product will no longer operate.
2 Remove the soft-touch rib by inserting a screwdriver under it
A
C
C
and breaking it out.
3 Remove the nut from the brush head and place it onto the
handle.Tighten the nut onto the handle (A) until the housing comes loose and then pull the nut forward (B).
B
4 Insert a screwdriver between the electronic circuit board and
C
the plastic part close to each end of the battery; twist and break the connection between the battery and the electronic circuit board in 2 locations.
5 Separate the rechargeable battery from the appliance by means
C
of a screwdriver.
Please note that this process is NOT reversible
Guarantee & service
If you need information or if you have a problem, please visit the Philips website at www.philips.com or contact the Philips Customer Care Centre in your country (you will find its phone number in the worldwide guarantee leaflet). If there is no Customer Care Centre in your country, turn to your local Philips dealer or contact the Service Department of Philips Domestic Appliances and Personal Care BV.
ENGLISH 15
Guarantee restrictions
What is not covered by the terms of the international guarantee?
- Brush heads
- Damage caused by misuse, abuse, neglect or alterations
- Normal wear and tear, including chips, scratches, abrasions,
discoloration or fading
Troubleshooting
If you are unable to solve your problem by means of the troubleshooting guide below,contact your local Philips Customer Care Centre or online at www.philips.com.
Problem
The Sonicare toothbrush does not work
I feel a tickling sensation when I use the Sonicare.
The brush head rattles when I use the Sonicare.
The brush head chatters against my teeth.
Brushing seems less powerful.
Unpleasant odour
The LED blinks yellow.What does this mean?
The appliance has an extra 30 seconds of brushing time. What is this for?
Solution
Recharge the Sonicare for at least 24 hours. Make sure the Sonicare is plugged into a live socket and not into a
socket controlled by a light switch. You may need to re-attach or replace the brush head. You may experience a slight tickling/tingling sensation when using
Sonicare for the first time. As you become accustomed to brushing with Sonicare, this sensation will diminish.
Sonicare should produce a gentle hum during operation.Tightening the brush head nut can eliminate excessive rattling. If the rattling does not stop, you may need to replace the brush head.
This can be avoided by keeping the brush head properly oriented, with the brush head placed on the gumline at an angle of 45 degrees.
The handle may need recharging. The Easy-start feature may be active and needs to be deactivated
(see 'Special features'). The Dual Speed Control button may be set to Reduced Speed. You may need to clean your brush head. You may need to replace your brush head. Clean the handle, brush head and charger thoroughly (see 'Cleaning'). Replace the brush head with a new one. The blinking yellow LED indicates that fewer than 3 brushings remain.
Recharge the Sonicare for at least 24 hours. This function provides additional time for brushing troublesome areas
where plaque collects and gum disease starts. It is recommended you use the extra 30 seconds of brushing time to re-brush troublesome areas, massage your gums, or brush your tongue (see 'Special features').
DEUTSCH16
Komponenten
A Bürstenkopf B Farbring C Bürstenkopfmutter D Sonic-Handstück E Ein-/Ausschalter F Geschwindigkeitsschalter (nur bestimmte Gerätetypen) G Ladestandsanzeige (LED) (nur bestimmte Gerätetypen) H Ladegerät I Kabelaufwicklung J Deluxe Bürstenhalterung (nur bestimmte Gerätetypen)
Wichtig
Lesen Sie diese Bedienungsanleitung vor dem ersten Gebrauch des Geräts sorgfältig durch und bewahren Sie sie zur späteren Einsichtnahme auf.
Haben Sie nach dem Lesen dieser Bedienungsanleitung noch Fragen, wenden Sie sich bitte an ein Philips Service Center oder besuchen Sie unsere Website (www.philips.com).
Bei der Entwicklung der Sonicare\ wurde insbesondere auf Effizienz und Sicherheit geachtet. Bei der Benutzung elektrischer Geräte sind jedoch - vor allem in Anwesenheit von Kindern - stets besondere Vorsichtsmaßnahmen erforderlich.
Gefahr
So reduzieren Sie das Risiko lebensgefährlicher Stromschläge:
1) Platzieren Sie das Ladegerät so, dass es nicht in ein Waschbecken oder eine Badewanne fallen kann.
2) Tauchen Sie das Ladegerät nicht in Wasser oder andere Flüssigkeiten.
3) Greifen Sie nicht nach einem Ladegerät, das in eine Flüssigkeit gefallen ist. Ziehen Sie sofort den Netzstecker.
4) Benutzen Sie das Gerät nicht beim Baden.
5) Das Gerät wurde für eine bestimmte Netzspannung entwickelt und darf nicht an Stromnetze mit anderen Spannungen angeschlossen werden.
6) Beachten Sie die Spannungsangabe auf der Unterseite des Ladegeräts. Spannungskonverter und Netzteiladapter gewährleisten die richtige Anpassung der Spannung NICHT. Stecken Sie den Netzstecker nie mit Gewalt in die Steckdose.
Warnung
So reduzieren Sie die Gefahr von Verbrennungen, lebensgefährlichen Stromschlägen, Bränden oder Verletzungen:
1) Das Gerät darf von Kindern und Behinderten nur unter ständiger Aufsicht verwendet werden.
DEUTSCH
2) Benutzen Sie das Gerät ausschließlich nach Maßgabe dieser Bedienungsanleitung.Verwenden Sie kein Zubehör, das nicht vom Hersteller empfohlen wird. Beachten Sie oben die Hinweise zur Netzspannung.
3) Benutzen Sie das Ladegerät nicht, wenn das Netzkabel oder der Netzstecker beschädigt ist, das Gerät nicht ordnungsgemäß arbeitet, heruntergefallen, beschädigt oder nass geworden ist.Weitere Informationen erhalten Sie bei dem Philips Service Center in Ihrem Land.
4) Halten Sie das Netzkabel von heißen Oberflächen fern.
Medizinische Hinweise
1) Benutzen Sie keinen Bürstenkopf mit abgeknickten oder verbogenen Borsten. Beschädigte Borsten können beim Putzen der Zähne abbrechen.Wechseln Sie deshalb den Bürstenkopf spätestens nach 6 Monaten aus oder sobald er Abnutzungserscheinungen zeigt.
2) Fragen Sie vor dem Einsatz eines neuen manuellen oder elektrischen Produkts für die Zahnpflege Ihren Zahnarzt um Rat, wenn in den vergangenen 2 Monaten ein chirurgischer Eingriff an den Zähnen oder am Zahnfleisch vorgenommen wurde.
3) Setzen Sie sich mit Ihrem Zahnarzt in Verbindung, wenn nach Benutzung dieses Geräts starkes Zahnfleischbluten auftritt, oder wenn es auch nach mehr als einwöchiger Benutzung noch zu Blutungen kommt.
4) Haben Sie als Träger eines Herzschrittmachers oder ähnlicher Implantate Fragen zur Verwendung des Geräts, setzen Sie sich bitte mit Ihrem Arzt oder dem Hersteller des Schrittmachers bzw. des Implantats in Verbindung. Sonicare wurde getestet und entspricht den Sicherheitsstandards für elektromagnetische medizinische Apparate.
5) Die Sonicare-Zahnbürste ist ein Gerät zur individuellen Mundpflege und nicht für die Verwendung durch mehrere Patienten in einer Zahnarztpraxis oder Zahnklinik geeignet.
6) Dieses Produkt dient ausschließlich dem Reinigen von Zähnen, Zahnfleisch und Zunge. Setzen Sie es nicht für andere Zwecke ein.
17
Vorbereitungen
So bringen Sie den Sonicare-Bürstenkopf an:
1 Richten Sie die Vorderseite des Bürstenkopfs an der
C
Vorderseite des Handstücks aus. Die Schienen am Bürstenkopf müssen in die Führungen oben am Handstück passen. Schieben Sie den Bürstenkopf dann auf das Handstück.
18
DEUTSCH
2 Drehen Sie die Bürstenkopfmutter im Uhrzeigersinn fest.
C
Rattert der Bürstenkopf beim Gebrauch, ziehen Sie die Mutter fester an.
Laden der Sonicare\
Sonicare wird mit leeren Akkus geliefert und sollte während der ersten Tage mindestens 24 Stunden lang aufgeladen werden.
1 Stellen Sie das Handstück mit nach vorne zeigendem Sonicare-
C
C
Logo in das Ladegerät, um die Sonicare zu laden.Die Unterseite des Handstücks muss richtig im Ladegerät sitzen, damit der Kontakt gewährleistet ist.
Wird das Handstück nicht richtig in das Ladegerät gestellt,
leuchtet zwar die grüne Ladestands-LED,aber der Akku wird nicht geladen.
Handstücke anderer Sonicare-Modelle passen nicht in dieses Ladegerät und werden darin nicht richtig geladen. Drücken Sie ein solches Handstück nicht mit Gewalt in dieses Ladegerät, um Beschädigungen zu vermeiden. Wir empfehlen die Aufbewahrung der Sonicare im Ladegerät, damit der Akku jederzeit voll geladen ist. Das vollständige Laden des Sonicare-Akkus nimmt mindestens 24 Stunden in Anspruch.
Benutzung des Geräts
Nützliche Tipps
Sie können Ihre bevorzugte Zahnpasta mit der Sonicare
verwenden.
Der Bürstenkopf wird mit einer praktischen Kappe für Reisen
geliefert. Nehmen Sie die Kappe vom Bürstenkopf,bevor Sie die Sonicare einschalten.
Führen Sie den Bürstenkopf in den Mund,bevor Sie Ihre Sonicare
einschalten; schalten Sie das Gerät aus, bevor Sie die Zahnbürste aus dem Mund nehmen: So vermeiden Sie Spritzer von Zahnpasta.
Spülen Sie Bürstenkopf und Borsten nach jedem Gebrauch.Reinigen Sie den Bürstenkopf wöchentlich, auch unter der Mutter.Eine vollständige Ladung der Sonicare reicht bei normalem
Gebrauch ca. 2 Wochen (zweimal täglich 2 Minuten putzen). Sie können die Sonicare also problemlos ohne Ladegerät mit auf Reisen nehmen.
DEUTSCH
Beachten Sie, dass Spannungskonverter und Netzteiladapter KEINE ordnungsgemäße Spannungsanpassung garantieren. Achten Sie immer auf die richtige Netzspannung.
Tipps zu speziellen Zahnpflegeanforderungen
Verfärbungen
Putzen Sie stark verfärbte Bereiche einige Sekunden länger, um die Entfernung der Verfärbungen zu verbessern.
Zahnspangen
C
Die Bürste sollte in einem Winkel von 45 Grad zwischen Zahnfleischsaum und Zahnspange platziert werden. Bewegen Sie die Borsten dann unter leichtem Druck in kleinen Kreisen so, dass die längeren Borsten 2 Sekunden lang zwischen die Zähne gelangen. Drehen Sie dann das Handstück, damit die Borsten die Zahnspange und den Rest des Zahns reinigen, bevor Sie mit dem nächsten Zahn fortfahren. Wiederholen Sie dies, bis alle Zähne gereinigt sind.
Zahnersatz
Verwenden Sie die Sonicare auf Zahnersatzteilen (Implantate, Inlays, Kronen, Brücken, Füllungen usw.) wie auf normalen Zahnflächen, um die Plaque zu entfernen und die Gesundheit des Zahnfleisches sicherzustellen. Bewegen Sie die Borsten über alle Flächen des Zahnersatzes, um diesen gründlich zu reinigen.
Parodontosetaschen
Möglicherweise hat Ihr Zahnarzt Parodontosetaschen diagnostiziert. Dabei handelt es sich um tiefe Spalten zwischen Zahn und Zahnfleisch, in denen sich Bakterien ansammeln. Ist dies der Fall, sollten Sie sich nach dem normalen zweiminütigen Putzen noch etwas Zeit nehmen, die betroffenen Bereiche sanft zu bürsten, um die Gesundheit des Zahnfleisches zu verbessern. Dabei empfiehlt sich der Einsatz der programmierbaren Quadpacer\ Timer-Funktion (siehe Abschnitt "Programmierbarer Quadpacer-Timer").
19
Die richtige Zahnputztechnik
Befolgen Sie diese einfachen Schritte, und Sie werden optimale Putzergebnisse erzielen:
1 Platzieren Sie die Borsten in einem Winkel von 45 Grad zum
C
Zahnfleischsaum, bevor Sie die Sonicare einschalten.
2 Halten Sie das Handstück locker in der Hand, schalten Sie das
Gerät ein, und führen Sie die Zahnbürste über die Zähne.
3 Die Sonicare arbeitet am wirksamsten, wenn Sie nur geringen
Druck ausüben und das eigentliche Putzen der Bürste überlassen. Schrubben Sie Ihre Zähne nicht!
20
DEUTSCH
4 Der angewinkelte Bürstenkopf und der schmale Hals
erleichtern das Erreichen der Backenzähne sowie der Zahnflächen im Inneren des Mundes. Halten Sie die Zahnbürste so, dass immer möglichst viele Borsten Kontakt zu den Zähnen haben.
5 Damit alle Zähne gleichmäßig geputzt werden, teilen Sie Ihren
C
Mund in 4 Abschnitte auf: Oberkiefer außen, Oberkiefer innen, Unterkiefer außen, Unterkiefer innen. Beginnen Sie mit Abschnitt 1 (Außenseite Oberkiefer) und putzen Sie 30 Sekunden lang, bevor Sie zu Abschnitt 2 (Oberkiefer innen) wechseln. Putzen Sie dann die anderen beiden Abschnitte jeweils 30 Sekunden lang, bis Sie nach 2 Minuten den Putzzyklus beendet haben. Bei aktiviertem programmierbarem Quadpacer\-Timer erinnert ein Tonsignal nach jeweils 30 Sekunden daran, zum nächsten Abschnitt zu wechseln.
6 Nach dem 2-minütigen Putzzyklus schaltet sich die Sonicare
automatisch aus. Sie können die Zahnbürste auch für einen weiteren Putzzyklus wieder einschalten und sich zum Putzen der Kauflächen noch etwas Zeit nehmen.
7 Sie können auch die Zunge putzen. Dabei schalten Sie nach
Belieben die Zahnbürste ein oder aus.
8 Unter Umständen tritt nach der ersten Benutzung einer
elektrischen Zahnbürste wie der Sonicare ein Kitzeln oder Kribbeln auf. Sobald Sie sich an die Sonicare gewöhnt haben, lässt diese Empfindung nach.
Besondere Merkmale
Produkteigenschaften, die das Zähneputzen erleichtern:
Easy-start\ steigert die Putzleistung langsam
Alle Sonicare-Modelle werden mit aktivierter Easy-start-Funktion
geliefert, damit Sie sich leichter an das Putzen mit der Sonicare gewöhnen.
Die Putzleistung wird während der ersten 14 Putzzyklen langsam
bis zur Maximalleistung gesteigert.
Die Funktion Easy-start ist aktiv, wenn Sie unmittelbar nach dem
Einschalten der Sonicare 2 Signaltöne hören. Sobald das Gerät die optimale Putzleistung erreicht hat (nach dem 14. Putzen), hören Sie diese Signaltöne beim Einschalten des Geräts nicht mehr.
B
Hinweis: Jeder der ersten 14 Putzzyklen muss mindestens eine Minute dauern, damit der jeweilige Zyklus von der Easy-start-Funktion berücksichtigt wird.
DEUTSCH
So aktivieren bzw. deaktivieren Sie die Funktion Easy-start:
1 Bringen Sie den Bürstenkopf am Handstück an.
2 Stellen Sie das Handstück in das angeschlossene Ladegerät.
3 So deaktivieren Sie Easy-start:
Halten Sie den Ein-/Ausschalter für 2 Sekunden gedrückt. Sie hören einen Signalton, sobald die Funktion Easy-start deaktiviert wurde.
4 So reaktivieren Sie Easy-start:
Halten Sie den Ein-/Ausschalter gedrückt, bis Sie zwei Signaltöne hören. Diese Signaltöne melden die Reaktivierung der Funktion Easy-start.
Die Funktion Easy-start sollte nur in der ersten Gewöhnungsphase genutzt werden, da sie die Effizienz der Plaque-Entfernung mit der Sonicare reduziert.
Bei klinischen Vergleichsstudien mit der Sonicare sollte die Easy-start Funktion deaktiviert sein.
2-Minuten-Timer Smartimer\
Alle Sonicare-Modelle sind mit dem Smartimer ausgestattet, der
automatisch für die Einhaltung der von Zahnmedizinern empfohlenen Putzdauer von 2 Minuten sorgt. Nach diesen 2 Minuten schaltet sich die Zahnbürste automatisch aus.Wollen Sie länger putzen, drücken Sie einfach den Ein-/Ausschalter, damit ein neuer 2-Minuten-Zyklus beginnt.
Sie können den 2-Minuten-Zyklus ab- oder unterbrechen, indem
Sie den Ein-/Ausschalter drücken.Wenn Sie den Ein-/Ausschalter nochmals drücken, wird die Zählung des Timers fortgesetzt.
21
B
Der Smartimer wird automatisch wieder auf Null gestellt, wenn Sie
- das Putzen länger als 30 Sekunden unterbrechen,
- das Handstück in das Ladegerät stellen.
30-Sekunden-Intervalltimer Quadpacer\
Die Quadpacer-Funktion sorgt dafür,dass Sie alle Bereiche im
C
Mund gleichmäßig und gründlich putzen. Nach jeweils 30 Sekunden (also nach 30, 60 und 90 Sekunden) eines
-minütigen Putzzyklus ertönt ein Signal, und der Putzzyklus wird kurz unterbrochen. Sie sollten das Putzen nun im nächsten Abschnitt fortsetzen.
22
DEUTSCH
Programmierbarer Quadpacer-Timer (nur bestimmte Gerätetypen)
Mit dem programmierbaren Quadpacer-Timer können Sie den Quadpacer auf eine von drei Funktionen einstellen:
Sie können die werkseitige Standardeinstellung eines
zweiminütigen Putzzyklus mit aktivierten Signaltönen des programmierbaren Quadpacers beibehalten.
Sie können den Putzzyklus auf 2,5 Minuten verlängern, indem Sie
eine Putzzeit von 30 Sekunden hinzufügen.
Sie können die Quadpacer-Signaltöne für den 2-Minuten-
Putzzyklus deaktivieren.
So ändern Sie die Einstellung des programmierbaren Quadpacers:
1 Stellen Sie das Handstück in ein Ladegerät, das an eine
C
stromführende Steckdose angeschlossen ist.
2 Drücken Sie kurz auf den Geschwindigkeitsschalter und
merken Sie sich, welche LED aufleuchtet.
3 Halten Sie den Geschwindigkeitsschalter gedrückt, während die
LED nacheinander die verschiedenen Einstellungsmöglichkeiten anzeigen:
Grüne LED in Position 4: Programmierbarer Quadpacer aktiviert
C C
C
(werkseitige Standardeinstellung).
Grüne LED in Position 5 (oben): 2,5 Minuten eingestellt:
Programmierbarer Quadpacer aktiv mit zusätzlicher Putzzeit von 30 Sekunden.
Gelbe LED in Position 1 (unten): Keine Intervalle programmiert:
Quadpacer nicht aktiviert.
4 Lassen Sie den Geschwindigkeitsschalter los, sobald die
gewünschte Einstellung erscheint: Diese Einstellung ist jetzt aktiviert.
B
Hinweis: Durch die Verlängerung der Putzzeit auf 2,5 Minuten reduziert sich die Anzahl möglicher Putzzyklen pro Akkuladung.
DEUTSCH
2 Geschwindigkeiten (nur bestimmte Gerätetypen)
Mit dem Geschwindigkeitsschalter können Sie eine von 2 Geschwindigkeiten aktivieren: Normale Geschwindigkeit für optimale Putzleistung und reduzierte Geschwindigkeit für eine besonders sanfte Reinigung.
Wenn Sie die Sonicare einschalten,startet sie mit normaler Geschwindigkeit. So können Sie die Geschwindigkeit ändern:
1 Von normaler zu reduzierter Geschwindigkeit: Drücken Sie den
C
Geschwindigkeitsschalter einmal während des Putzens.
2 Von reduzierter zu normaler Geschwindigkeit: Drücken Sie den
Geschwindigkeitsschalter während des Putzens erneut.
Ein zweistufiges Tonsignal meldet die Änderung der Geschwindigkeit.
Wir empfehlen die normale Putzgeschwindigkeit für optimale Ergebnisse.
Bei klinischen Tests der Sonicare muss die Geschwindigkeitsstufe "Normal" verwendet werden.
Akkuladestandsanzeige (nur bestimmte Gerätetypen)
Ist der Ladestand der Akkus in der Sonicare gering, hören Sie nach
C
dem zweiminütigen Putzzyklus 3 Signaltöne.Außerdem blinkt die Ladestand-LED 30 Sekunden lang gelb.
Eine niedrige Ladestandsanzeige bedeutet, dass die Energie für weniger als drei 2-minütige Putzzyklen ausreicht. Bewahren Sie die Sonicare im Ladegerät auf, um jederzeit über die volle Akkuladung zu verfügen.
23
Ladestandsanzeige (mehrere LED) - (nur bestimmte Gerätetypen)
Wenn sich das Handstück im Ladegerät befindet, blinken die
grünen Ladestands-LED in ansteigender Folge, während der Akku geladen wird. Die Anzahl der blinkenden LED kennzeichnet den erreichten Ladestand.
Sobald der Akku vollständig geladen ist,blinken die LED nicht mehr, sondern leuchten kontinuierlich. Etwa ein Mal pro Minute erlöschen die LED kurz und leuchten dann wieder auf, um die Erhaltung der vollen Akkuladung zu melden. Der Status der Ladestandsanzeige ändert sich, sobald Sie das Handstück aus dem Ladegerät nehmen. Wenn die gelbe LED blinkt, sind nur noch weniger als 3 Putzzyklen möglich.
24
DEUTSCH
Ladestandsanzeige (1 LED) - (nur bestimmte Gerätetypen)
Wenn sich das Handstück im Ladegerät befindet, blinkt die
C
C
C
Ladestands-LED grün, während der Akku geladen wird. Sobald der Akku vollständig geladen ist, leuchtet die Ladestands-LED kontinuierlich grün, bis das Handstück aus dem Ladegerät genommen wird.
Wird die Sonicare ein- oder ausgeschaltet, blinkt die Ladestands-LED gelb, wenn der Ladestand niedrig ist.
Deluxe Bürstenhalterung (nur bestimmte Gerätetypen)
Einige Sonicare-Modelle werden mit einer Deluxe
Bürstenhalterung geliefert.
Die Halterung kann mit 2 Schrauben (3,0 x 30 mm) und 2 Dübeln
(nicht mitgeliefert) an der Wand montiert werden.
Reinigung
Hinweise zur Pflege des Geräts
Die folgenden einfachen Schritte sorgen über Jahre für eine problemlose Zahnpflege:
1 Spülen Sie Bürstenkopf und Borsten nach jedem Gebrauch.
C
DEUTSCH
2 Reinigen Sie den Bürstenkopf wöchentlich, auch unter der
C
C
C
C
Mutter.
3 So lösen Sie die Mutter:
Drücken Sie vorsichtig auf den grauen Siegelbereich.
Verwenden Sie dabei keine scharfen Gegenstände, um Beschädigungen zu vermeiden.
Ziehen Sie die Mutter nach oben über das Ende des Bürstenkopfs.
4 Befestigen Sie die Mutter wieder, indem Sie die Mutter über
den Schaft des Bürstenkopfs schieben und den unteren Teil des Bürstenkopfs in das Handstück drücken.Drehen Sie die Mutter im Uhrzeigersinn fest, bis sie im Siegel einrastet.
5 Reinigen Sie das Handstück wöchentlich.
25
6 Reinigen Sie das Ladegerät regelmäßig.
Trennen Sie das Ladegerät vor dem Reinigen vom Stromnetz.
7 Überprüfen Sie gelegentlich das Netzkabel. Benutzen Sie das
Ladegrät nicht, wenn das Netzkabel beschädigt ist.
8 Überschüssiges Kabel können Sie um die Führungen unten im
Ladegerät wickeln.
TRENNEN Sie das Ladegerät vor dem Reinigen vom Stromnetz Trocknen Sie das Ladegerät nach dem Reinigen vollständig, bevor Sie es wieder mit dem Stromnetz verbinden.
Zum Reinigen der Sonicare empfehlen wir milde Seife,Wasser und ein weiches Tuch.
26 DEUTSCH
Ersatzteile
Bürstenkopf
Damit dauerhaft optimale Resultate erzielt werden, müssen Sonicare­Bürstenköpfe spätestens nach 6 Monaten oder bereits früher ausgetauscht werden, wenn Abnutzungserscheinungen sichtbar werden.
Verwenden Sie ausschließlich Bürstenköpfe der Serie Sonicare Elite\.
Umweltschutz
Das Gerät enthält einen Nickel-Kadmium-Akku. Der Akku muss ordnungsgemäß entsorgt oder recycelt werden, um Umweltschäden zu vermeiden.
Der Akku in der Sonicare kann nicht ausgetauscht,aber zum Zweck der Entsorgung problemlos entnommen werden.Vor der Entsorgung des Geräts sollten Sie den Akku anhand der folgenden Anleitung entnehmen. Dieser Vorgang ist NICHT umkehrbar.
Werfen Sie den Akku auf keinen Fall in den Hausmüll, sondern
C
geben Sie ihn an einer offiziellen Sammelstelle ab.
Informationen zum Recyclingprogramm für Sonicare-Akkus sowie zum Recycling der Sonicare erhalten Sie bei Ihrem Philips Service-Center.
Ausbauen des Akkus
Seien Sie vorsichtig, wenn Sie Werkzeuge (z. B. Schraubendreher) zum Ausbauen des Akkus einsetzen.
1 Entladen Sie den Akku vollständig, indem Sie das Handstück aus
dem Ladegerät nehmen, die Sonicare einschalten und laufen lassen, bis der Motor stoppt.Wiederholen Sie diesen Vorgang, bis das Gerät nicht mehr läuft.
2 Entfernen Sie den weichen Griffgummi, indem Sie einen
C
A
B
C
Schraubendreher darunter schieben und ihn herausbrechen.
3 Lösen Sie die Mutter vom Bürstenkopf und platzieren Sie sie
auf dem Handstück. Ziehen Sie die Mutter auf dem Handstück (A) fest, bis sich das Gehäuse löst. Ziehen Sie die Mutter dann nach vorne (B).
Loading...
+ 58 hidden pages