Philips HR4325A Service Manual

Philips Domestic Appliances and Personal Care
Air Cleaner
HR 4325/A
PRODUCT INFORMATION
GENERAL
The HR 4325 is suitable for room / areas with a floor surface of up to approx. 30 m2. The air cleaner purifies the air effectively by catching up to 99 % of the airborne particles.
This is done by 3 filters :
Foam pre-filter : The foam pre-filter catches the larger
dust particles floating in the air, such as fluff and hairs.
ROTA filter : The ROTA filter takes out the particles
of 2 microns and more (pollen).
HEPA filter HR4920 : This filter takes out all the remaining
smaller particles.
This product meets the requirements regarding interference suppression on radio and TV.
FEATURES
Filter full indicator: Once the indication light comes on, the
filter has to be replaced. After replacement of the filters, the filter full indicator has to be reset. The reset button has to be pressed and hold for at least 3 seconds. The indication light remains ( or comes ) on. After some time it will go out to indicate that the indicator has been reset.
Electronic speed setting: 0 - 1 - 2 and turbo.
Safety lock: The front cover has a safety lock.
A nock of the frontcover operates the microswitch of the PCB when the front cover is closed. Once the front cover is removed the microswitch interrupts the electric circuit and the motor stops.
Over heating safety device: The overheating safety device comes into operation when the motor becomes too hot. To indicate that the appliance is still in “ ON ” position and connected to the mains, the pilot light remains on. If this happens : Switch off the motor.
After approx. 15 min. the air cleaner can be
switched on again.
TECHNICAL DATA
Voltages : 100 volt, 70 Watts / 50 Hz
Filters : 2 HEPA filters HR4920 Life time HEPA filters : Max. 6 months Flow rate : 172 m3: 230 V, 50 Hz
Total filter surface : 1 m Room / area size : Max. 30 m
Published by Philips Domestic Appliances and Personal Care Printed in the Ne therlands
4822 729 21838 97/06
PCS 88 808
110 - 127 volt, 120 Watts / 60 Hz 220 - 240 volt, 70 Watts / 50 Hz
: 220 m3: 120 V, 60 Hz
2
2
©
Copyright reserved Subject to modification
POSSIBLE COMPLAINTS PARTS LIST HR 4325/A
1) The motor makes an irritating noise.
Check if : The HEPA filters are positioned properly in the
air cleaner.
: The filters have to be cleaned or replaced. : The ROTA filter and / or fan have been
properly fitted and can be rotated freely by hand.
2) The overheating device comes into operation.
Check : If the filters are blocked and nothing is
obstructing the air inlet and air outlet openings.
: That the ROTA filter and / or fan have been fitted
properly and can rotated freely by hand.
In case these problems still remains, replace the motor (item
13.0) and belonging buffers (item 13.1).
MAINTENANCE
Pre-filter : Wash or vacuum clean the foam pre-filter at
least every 2 months. Fluff and /or hairs can also be removed by using a soft brush. Replacement filters are available under service code 4822 480 10116
NEVER USE WET FILTERS.
ROTA filter: Wash or vacuum clean the ROTA filter at least
every 2 months. If washed with a detergent, rinse the filters with clean warm water and allow the filters to dry in the air thoroughly before reassembly.
NEVER USE WET FILTERS.
Replacement ROTA filters are available under service code 4822 480 10089
HEPA filter : For a proper operation replace these filters at
least every six months. Replacement HEPA filters are available under type number HR4920 and service code 4822 480 10087.
POS DESCRIPTION SERVICE CODE
1 front cover 4822 442 00121
2 HEPA filter HR 4920 4822 480 10087
3 foam pre-filter 4822 480 10116
4 control panel + insert 119 4822 310 11051
6 pcb control unit 4822 214 12408
7 microswitch + bracket 4822 310 11052
8 frame pcb 4822 464 10344
9 air outlet 4822 458 10464
10 front housing 4822 310 10971
consisting of : front housing 10
hole plug 105 safety grill 106 2x foot 107 2x
11 ROTA filter 4822 310 10972
12 fan 4822 310 10973
consisting of : fan 12
lock washer 108 washer 109 nut M6 110 nut cover 111
13.0 motor 220 - 240 V 4822 361 10784 motor 110 - 120 V 4822 361 10785 motor 100 V 4822 361 10786
13.1 set buffers 4822 310 10648
containing: rubber buffers 112 3x
metal bracket 113 3x bush 115 3x
14 rear housing 4822 310 10974
consisting of: rear housing 14
foot 107 2x
15 rear cover 4822 442 00122
18 housing parts supply pcb 4822 310 11053
19 supply pcb 220 - 240 V 4822 214 12409
supply pcb 110 - 120 V 4822 214 12411 supply pcb 100 V 4822 214 12412
Parts, with numbers from 100 and higher, cannot be ordered separately.
NOTES
* N.B. Concerns Panel 4 :
for standardisation reasons, the insert 116 of the Air Cleaner HR 4345 is delivered too.
* After the product has been repaired, it should
function properly and has to meet the safety requirements and legal regulations as laid down and officially established at this moment.
PCS 88 809