Philips Domestic Appliances and Personal Care
BOX FAN
HR 3287
PRODUCT INFORMATION
The HR 3287 is a box fan with 3 fan speeds, a timer and a
rotating louvre.
Available voltages : 220 - 240 V / 50-60 Hz
110 - 127 V / 50-60 Hz
Fan blade size : 12 “ or 30 cm
Timer : max 3 hours
Switches for : - ON / OFF louvre rotation
- speed selection fan.
Fan speed selector : 4 positions 0-1-2-3
Air displacement : max. 55 m3/ min
Power consumption : 55 Watts
Safety switch
Red pilot lamp
Adjustable inclination angle 0 - 7.5° - 15°
Internal cord storage
Product meets the requirements regarding interference
suppression on radio and T.V.
Safety switch : The automatic safety switch will switch off the
fan, when it’s lifted or turned over during
operation
Published by P hilips Domestic Appliances and Personal Care Printed in the Netherlands
4822 729 21566
96/01
PCS 86 669
©
Copyright reserved Subject to modification
DISASSEMBLY ADVICE PARTS LIST HR 3287
GRILLE 1
To replace grille:
remove Screw A (2x)
remove Lock plate 2
ORNAMENTAL
PLATE 3
To replace plate:
remove Grille I
remove Screw B (2x)
FAN BLADE 5
To replace fan blade:
remove Grille I
remove Cap fan 4
TIMER KNOB 6
SPEED CONTROL
KNOB 6
KNOB LOUVRE
ROTATION 7
To replace knobs
TIMER 8
ADAPTER TIMER 9
CAPACITOR 12
LOUVRE MOTOR 13
For replacement
remove Timer knob 6
remove Speed control knob 6
remove Knob louvre switch 7
remove Grille 1
remove Screw C (8x)
remove Rear housing 102
remove Screw I Capacitor (lx)
remove Screw J
Louvre motor (2x)
unsolder wiring
SWITCH PLATE 15
SWITCH SPEED
CONTROL 16
remove Timer knob 6
remove Speed control knob 6
remove Knob louvre switch 7
remove Grille 1
remove Screw C (8x)
remove Rear housing 102
remove Screw D (2x)
remove Switch plate 15
remove Screw E (2x)
remove components
unsolder wires
MOTOR 17
remove Timer knob 6
remove Speed control knob 6
remove Knob louvre switch 7
remove Grille 1
remove Fan blade 5
remove Srew C (8x)
remove Rear housing 102
remove Screw F (4x)
remove Motor mount 103
remove Screw G (4x)
remove / unsolder wires
SAFETY SWITCH 19
KNOB SAFETY
SWITCH 18
for replacement
remove Rubber feet 22 (4x)
remove Screw H (4x)
remove Bottom plate 105
remove / unsolder wiring
POS. DESCRIPTION SERVICE CODE
1 GRILLE 4822 458 10479
2 LOCK PLATE 4822 466 10954
3 ORNAMENTAL PLATE 4822 466 10955
4 FAN CAP 4822 462 10693
5 FAN BLADE 4822 515 10053
6 TIMER / SPEED CONTROL 4822 410 10378
7 PUSH BUTTON LOUVRE 4822 410 10379
8 TIMER 220-240 VOLT 4822 282 10283
8 TIMER 110-127 VOLT 4822 282 10284
9 ADAPTER TIMER KNOB 4822 263 21098
10 APAPTER SPEED CONTROL 4822 263 21099
11 SWITCH LOUVRE 110-240 V 4822 276 13706
12 CAPACITOR 220-240 V 4822 121 10522
12 CAPACITOR 110-127 V 4822 121 10523
13 OSCILL. MOTOR 220-240 V 4822 361 10814
13 OSCILL. MOTOR 110-127 V 4822 361 10815
14 PILOT LAMP 220-240 V 4822 134 10026
14 PILOT LAMP 110-127 V 4822 134 10027
15 SWITCH PLATE 4822 466 10956
16 CONTR. SWITCH 110-240 V 4822 273 10306
17 MOTOR 220-240 V 4822 361 10816
17 MOTOR 110-127 V 4822 361 10817
18 SAFETY KNOB 4822 410 10381
19 SAFETY SWITCH 220-240 V 4822 276 13707
19 SAFETY SWITCH 110-127 V 4822 276 13708
20 FIXING NUT LOUVRE 4822 505 11217
21 LOUVRE + BEARING BUSH 4822 458 10481
22 RUBBER FOOT 4822 462 10694
SK3
B
L
N
SK2SK1
A
SK1 = SAFETY SWITCH
= TIMERSK2
= SPEED SELECTOR SWITCHSK3 = LOUVER MOTOR
4
3
2
1
CIRCUIT DIAGRAM
SK4
M1
M2
SLOW
MED
FAST
F
115˚C
M1
C1
R
GL
= SWITCH LOUVER MOTOR
= MOTOR FAN
SK4
M2
ADAPTER SPEED
CONTROL 10
LOUVRE SWITCH 11
CORDSET 101
PILOT LAMP 14
For replacement:
remove Timer knob 6
remove Speed control knob 6
remove Knob louvre switch 7
remove Grille 1
remove Screw C (8x)
remove Rear housing 102
remove / unsolder wires
PCS 86 850
IMPORTANT
* IN SOME CASES THE CONNECTION POINTS BETWEEN WIRING AND ELECTRICAL
COMPONENTS HAVE BEEN INSULATED.
AFTER REPLACEMENT OF A COMPONENT, MAKE SURE THAT THE ELECTRICAL INSULATION
OF THE CONNECTION POINTS HAS BEEN RESTORED BY FITTING THE REGULAR SLEEVE.
IF THIS REGULAR SLEEVE CANNOT BE USED ANYMORE, REPLACE IT WITH A NEW ONE OR
USE INSULATING TAPE, TAKING CARE A PROPER AND SAFE INSULATION IS REALIZED.
* AFTER THE PRODUCT HAS BEEN REPAIRED, IT SHOULD FUNCTION PROPERLY AND HAS TO
MEET THE SAFETY REQUIREMENTS AND LEGAL REGULATIONS AS LAID DOWN AND
OFFICIALLY ESTABLISHED AT THIS MOMENT.
* PARTST, WITH NUMBERS FROM 100 UPWARDS, CANNOT BE ORDERED SEPARATELY.