Philips HQ4441A Service Manual

Mains Shaver

Service

Service

Service

Domestic Appliances and Personal Care

HINTS FOR REPAIRS

 

 

 

 

 

 

 

 

 

 

 

 

a. Disassembly

 

 

 

 

 

 

 

 

 

 

 

 

-

Remove shaving unit, to prevent damages

 

SK1

 

 

 

L1

 

 

 

 

 

 

 

during a repair.

100-240 V

R1

 

 

 

 

 

 

 

 

 

-

 

 

 

 

 

 

 

 

 

 

 

 

Remove the screws A1 (4x).

 

 

 

 

C1

 

 

 

 

C2

 

 

- Put the shaver on the table and remove the cover

 

D1

D4

 

 

 

 

 

 

 

 

 

 

from the shaver.

 

 

 

 

 

 

 

 

 

D5

R1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-

Pull the connection leads out of the terminals on the

 

 

 

 

 

R2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-

bearing block of the motor and remove the p.c.-board.

 

 

 

 

 

 

 

 

 

 

M

C4

Loosen the motor clamping springs on the bearing

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-

block with a small screwdriver.

 

 

 

 

 

 

 

 

 

 

 

 

Remove the motor.

 

 

16

15

14

13

12

11

10

9

 

 

- Remove the screws A2 (2x)

 

 

 

 

 

 

 

 

 

 

IC1

 

 

R5

L2

 

-

Unlock the peg clamping (3x) between frame and

 

 

 

 

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

 

 

 

hair chamber.

 

 

 

 

-

 

 

 

 

 

 

 

 

 

 

 

 

Remove the gearwheels and trimmer drive.

 

 

 

 

 

 

R3

 

 

C3

 

 

-

To remove the trimmer, first disassemble the trimmer

 

4852

 

 

 

 

 

 

 

 

 

 

 

slide by pushing down the locking pegs (4x ”X” in

 

4853

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

exploded view) and move the slide slightly outwards.

 

 

 

 

 

 

 

 

 

 

 

 

-Make room between trimmer and cover with a small

screwdriver (”Y” in exploded view).

TECHNICAL DATA

b. Assembly

-The assembly must be carried out in reverse order of what is described under a. Disassembly.

CAUTION!

WHILE CHECKING THE P.C.-BOARD REMEMBER THAT MOST COMPONENTS AND THE MOTOR ARE ENERGIZED BY MAINS VOLTAGE.

Voltage

:

100-240 V 50/60Hz

Power consumption

:

Motor depending

Motor voltage

:

54 V

 

 

 

Power supply

:

SMPS

Shaving heads

:

HQ4 - 4822 690 30468

Comfort control

:

fixed setting

SAP coding

:

HQ4441

Published by Philips Domestic Appliances and Personal Care Printed in The Netherlands © Copyright reserved Subject to modification

4322 277 00182

00/01

Philips HQ4441A Service Manual

HQ 4441/A

17

18

2

3

+ -

4

5

 

 

 

7

 

 

 

 

 

8

 

 

 

 

 

9

 

 

 

 

 

10

 

19

 

 

 

 

 

 

 

 

11

 

20

 

 

 

 

 

 

 

 

12

 

21

 

 

 

 

 

 

 

 

13

 

 

 

 

 

14

 

 

76

 

 

15

 

 

 

 

 

 

 

 

 

 

16

 

 

1

4822 441 11276

Protecting cap

16

4822 492 62703

Contact spring

2

4222 036 01980

Head holder

17

4822 690 10081

Trimmer

3

4822 690 30468

HQ4 shaving head

18

4222 036 02010

Power module

4

4822 404 40728

Retaining bracket

19

4222 036 02140

Cover

5

4222 036 02130

Housing Ph

20

4822 321 10095

Flex EU

6

4822 122 31177

Capacitor 470 pF

-

4222 036 01590

Flex RA

7

4822 267 31319

Inlet

-

4822 321 10344

Flex USA/CDN

8

4222 036 02920

Hairchamber

21

4822 479 30183

Cleaning brush

9

4822 522 33041

Gearwheel

A

4822 502 30526

S.t. screw 1.8x10/T8

10

4822 404 40656

Lever

 

4222 036 00040

Pouch

114822 441 11275 Frame

124822 522 33039 Pinion

134822 361 30247 Motor

144822 492 63165 Motor clamp

154822 362 40181 Carbon brush

Loading...