HINTS FOR REPAIRS

 

 

 

 

 

 

 

 

 

 

 

 

a. Disassembly

 

 

 

 

 

 

 

 

 

 

 

 

-

Remove shaving unit, to prevent damages

 

SK1

 

 

 

L1

 

 

 

 

 

 

 

during a repair.

100-240 V

R1

 

 

 

 

 

 

 

 

 

-

 

 

 

 

 

 

 

 

 

 

 

 

Remove the screws A1 (4x).

 

 

 

 

C1

 

 

 

 

C2

 

 

- Put the shaver on the table and remove the cover

 

D1

D4

 

 

 

 

 

 

 

 

 

 

from the shaver.

 

 

 

 

 

 

 

 

 

D5

R1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-

Pull the connection leads out of the terminals on the

 

 

 

 

 

R2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-

bearing block of the motor and remove the p.c.-board.

 

 

 

 

 

 

 

 

 

 

M

C4

Loosen the motor clamping springs on the bearing

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-

block with a small screwdriver.

 

 

 

 

 

 

 

 

 

 

 

 

Remove the motor.

 

 

16

15

14

13

12

11

10

9

 

 

- Remove the screws A2 (2x)

 

 

 

 

 

 

 

 

 

 

IC1

 

 

R5

L2

 

-

Unlock the peg clamping (3x) between frame and

 

 

 

 

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

 

 

 

hair chamber.

 

 

 

 

-

 

 

 

 

 

 

 

 

 

 

 

 

Remove the gearwheels and trimmer drive.

 

 

 

 

 

 

R3

 

 

C3

 

 

-

To remove the trimmer, first disassemble the trimmer

 

4852

 

 

 

 

 

 

 

 

 

 

 

slide by pushing down the locking pegs (4x ”X” in

 

4853

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

exploded view) and move the slide slightly outwards.

 

 

 

 

 

 

 

 

 

 

 

 

-Make room between trimmer and cover with a small

screwdriver (”Y” in exploded view).

TECHNICAL DATA

b. Assembly

-The assembly must be carried out in reverse order of what is described under a. Disassembly.

CAUTION!

WHILE CHECKING THE P.C.-BOARD REMEMBER THAT MOST COMPONENTS AND THE MOTOR ARE ENERGIZED BY MAINS VOLTAGE.

Voltage

:

100-240 V 50/60Hz

Power consumption

:

Motor depending

Motor voltage

:

54 V

 

 

 

Power supply

:

SMPS

Shaving heads

:

HQ4 - 4822 690 30468

Comfort control

:

fixed setting

SAP coding

:

HQ4411

Published by Philips Domestic Appliances and Personal Care Printed in The Netherlands © Copyright reserved Subject to modification

4322 277 00180

00/01

Philips HQ4411A Service Manual

HQ 4411/A

17

18

2

3

+ -

4

5

 

 

 

7

 

 

 

 

 

8

 

 

 

 

 

9

 

 

 

 

 

10

 

19

 

 

 

 

 

 

 

 

11

 

20

 

 

 

 

 

 

 

 

12

 

21

 

 

 

 

 

 

 

 

13

 

 

 

 

 

14

 

 

76

 

 

15

 

 

 

 

 

 

 

 

 

 

16

 

 

1

4822 441 11276

Protecting cap

16

4822 492 62703

Contact spring

2

4222 036 01980

Head holder

17

4822 690 10081

Trimmer

3

4822 690 30468

HQ4 shaving head

18

4222 036 02010

Power module

4

4822 404 40728

Retaining bracket

19

4222 036 02090

Cover

5

4222 036 02080

Housing Ph

20

4822 321 10095

Flex EU

6

4822 122 31177

Capacitor 470 pF

-

4822 321 10096

Flex GB

7

4822 267 31319

Inlet

-

4222 036 01590

Flex RA

8

4222 036 02920

Hairchamber

-

4822 321 10148

Flex AUS/NZ

9

4822 522 33041

Gearwheel

-

4822 321 10344

Flex USA/CDN

10

4822 404 40656

Lever

21

4822 479 30183

Cleaning brush

11

4822 441 11275

Frame

A

4822 502 30526

S.t. screw 1.8x10/T8

12

4822 522 33039

Pinion

 

4222 036 02120

Pouch

134822 361 30247 Motor

144822 492 63165 Motor clamp

154822 362 40181 Carbon brush