Philips HP6520 User Manual

Register your product and get support at
www.philips.com/welcome
HP6520
1
ENGLISH 6 EESTI 14 LIETUVIŠKAI 22 SLOVENSKY 30
HP6520
6

ENGLISH

Introduction
Congratulations on your purchase and welcome to Philips! To fully benet
from the support that Philips offers, register your product at www.philips.com/welcome.
General description (Fig. 1)
1 Double wavy massage attachment 2 Sensitive area cap 3 Epilating discs 4 Epilating head 5 On/off button
- press once for speed II
- press twice for speed I
- press three times to switch off 6 Charging light (white) with battery-low indication (red) 7 Socket for small plug 8 Adapter 9 Storage pouch 10 Exfoliation brush 11 Cleaning brush
Important
Read this user manual carefully before you use the appliance and save it for future reference.
Danger
- Keep the appliance and the adapter dry.
- Do not use the appliance near or over a washbasin or bath lled with
water.
- Do not use the appliance in the bath or in the shower.
- If you use the appliance in the bathroom, do not use an extension cord.
Warning
- Only charge the appliance with the adapter supplied.
- If the adapter is damaged, always have it replaced with one of the
original type in order to avoid a hazard.
- Fully charge the appliance every 3 to 4 months, even if you have not
used the appliance for a long time.
ENGLISH 7
- This appliance is not intended for use by persons (including children)
with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
- Children should be supervised to ensure that they do not play with the
appliance.
- The adapter contains a transformer. Do not cut off the adapter to
replace it with another plug, as this causes a hazardous situation.
- Do not insert metal-containing material into the socket for the
appliance plug to avoid short circuiting.
Caution
- This appliance is only intended for removing women’s body hair on
areas below the neck: underarms, bikini line and legs. Do not use it for any other purpose.
- To prevent damage and injuries, keep operating appliance (with or
without attachment) away from scalp hair, eyebrows, eyelashes, clothes, threads, cords, brushes etc.
- Do not use the appliance and exfoliation brush on irritated skin or skin
with varicose veins, rashes, spots, moles (with hairs) or wounds without
consulting your doctor rst.
- People with a reduced immune response or people who suffer from
diabetes mellitus, haemophilia or immunodeciency should also consult their doctor rst.
- Your skin may become a little red and irritated the rst few times you
use the epilator. This phenomenon is absolutely normal and quickly disappears. As you use the appliance more often, your skin gets used to epilation, skin irritation decreases and regrowth becomes thinner and softer. If the irritation has not disappeared within three days, we advise you to consult a doctor.
- For hygienic reasons, the appliance and exfoliation brush should only
be used by one person.
- Do not use the epilating head, attachments or the exfoliation brush if
they are damaged or broken, as this may cause injury.
- Charge, use and store the appliance at a temperature between 10°C
and 30°C.
- Make sure the socket is live when you charge the appliance. The
electricity supply to sockets in mirror cabinets over washbasins or shaver sockets in bathrooms may be cut off when the light is turned off.
- Maximum noise level: Lc= 76 dB(A)
Compliance with standards
This Philips appliance complies with all standards regarding electromagnetic
elds (EMF). If handled properly and according to the instructions in this user manual, the appliance is safe to use based on scientic evidence
available today.
ENGLISH8
General
- This symbol means that it is not allowed to use this appliance in a bath
or shower.
- This appliance complies with the applicable IEC safety standards.
- For safety reasons, this appliance can only be operated cordlessly.
- The adapter is equipped with an automatic voltage selector and is
suitable for mains voltages ranging from 100 to 240 volts.
Preparing for use
Charging
Charging the epilator takes approximately 1 hour. When the epilator is fully charged, it has a cordless operating time of up to 30 minutes.
1 Switch off the appliance before you charge it.
2 Insert the appliance plug into the socket in the bottom of the
appliance (1) and put the adapter in the wall socket (2).
, The charging light ashes white to indicate that the appliance is
charging.
, When the battery is fully charged, the charging light lights up white
continuously for 20 minutes and then goes out.
Battery low or empty
- When the battery is almost empty, the charging light starts to ash
red. When this happens, the battery still contains enough energy for a few minutes of epilating.
- When the battery is completely empty, the charging light lights up red
continuously. To charge the epilator, see section ‘Charging’ above.
ENGLISH 9
Using the appliance
Clean the epilating head and charge the appliance fully before you use the
appliance for the rst time.
Note: You cannot use the appliance while it is connected to the mains.
Epilating tips
- Epilation is easier just after taking a bath or shower. Make sure your skin
is completely dry when you start epilating.
- Make sure your skin is clean, entirely dry and free from grease. Do not
apply any cream to your skin before you start to epilate.
- We advise you to epilate before you go to bed at night, as skin
irritation usually disappears overnight.
- Epilation is easier and more comfortable when the hairs have a length
of 3-4mm. If the hairs are longer, we recommend that you shave rst
and epilate the shorter regrowing hairs after 1 or 2 weeks.
Epilating
Note: If you are new to epilation, start epilating with the double wavy massage attachment to minimise the pulling sensation of epilation. This attachment is only intended for epilating the legs.
Note: To epilate the underarms or bikini line, use the sensitive area cap that reduces the number of active epilating discs.
1 Put the attachment on the epilating head.
2 Press the on/off button once to switch on the appliance.
, The appliance starts to operate at speed II, which is the most
efcient speed for epilating.
Note: If you want to use speed I, press the on/off button a second time. Speed I is suitable for areas with little hair growth, for hard-to-reach areas and for areas where bones are located directly beneath the skin, such as knees and ankles.
3 Stretch the skin with your free hand to make the hairs stand upright.
Place the epilating head at an angle of 90° onto the skin with the on/ off button pointing in the direction in which you are going to move the appliance.
- Epilate your bikini line as shown in the gure.
ENGLISH10
- Epilate your underarms as shown in the gure.
4 Move the appliance slowly over the skin against the direction of hair
growth while pressing it lightly.
5 Press the on/off button a third time to switch off the appliance.
6 Pull the attachment off the epilating head.
Tip: To relax the skin, we advise you to apply a moisturising cream immediately or a few hours after epilation.
Tip: After epilation, use a gentle deodorant without alcohol or a special deodorising cream for epilated underarms.
Using the exfoliation brush
- You can use the exfoliation brush dry or wet to remove dead skin
cells gently and thoroughly. Make gentle circular movements with the exfoliation brush for a soft exfoliating effect. This helps to prevent ingrown hairs and gives you smooth, soft and fresh-looking skin.
- Brush your skin with the exfoliation brush one day before and two
days after epilating. After this, use it 2-3 times a week. Scrub your legs with gentle, circular movements, starting at the ankles.
Note: When you use the exfoliation brush on dry skin, do not use exfoliating creams, gels or foams.
Tip: To prevent dry skin in general, moisturise your skin daily with your preferred moisturising cream.
Do not use the exfoliation brush immediately after epilation, as this may intensify possible skin irritation caused by the epilator.
Overheat protection
This function helps to prevent overheating of the appliance.
Note: To avoid overheating of the epilator, do not press the appliance too hard onto your skin. The epilator works best when you move it over your skin without exerting any pressure.
If the overheat protection is activated, the appliance switches off
automatically and the charging light ashes red for 30 seconds.
You can reset the overheat protection by letting the appliance cool down and then switch it on again.
Note: If the charging light starts to ash red again, the appliance has not yet
cooled down completely.
ENGLISH 11
Overload protection
If you press the epilating head too hard onto your skin or when the epilating discs of the epilating head get blocked (e.g. by clothes etc.), the
appliance switches off and the charging light ashes red for 5 seconds.
Turn the epilating discs with your thumb until you can remove whatever is blocking the epilating discs.
Cleaning and maintenance
Never use scouring pads, abrasive cleaning agents or aggressive liquids such as petrol or acetone to clean the appliance.
Always keep the appliance and the adapter dry. Never rinse them under the tap or immerse them in water.
If necessary, clean the adapter with the cleaning brush or a dry cloth.
Cleaning the appliance
1 Switch off and unplug the appliance.
2 Pull the attachment off the epilating head.
3 Push the epilating head to the right (1) and remove it from the
appliance (2).
Note: Never try to detach the epilating discs from the epilating head.
4 Remove loose hairs with the cleaning brush.
5 Rinse all parts (except the appliance and the adapter) under the tap
and shake excess water off.
Note: Make sure all parts are completely dry before you reassemble the appliance.
Cleaning the exfoliation brush
1 Rinse the exfoliation brush under the tap, if necessary with some
soap or shower gel, and let it dry before you store it.
ENGLISH12
Replacement
If you need to replace a part or want to purchase an additional part, go to your Philips dealer or visit www.philips.com/shop. If you have problems obtaining the parts, please contact the Philips Consumer Care Centre in your country.
Environment
- Do not throw away the appliance with the normal household waste
at the end of its life, but hand it in at an ofcial collection point for
recycling. By doing this, you help to preserve the environment.
- The built-in rechargeable battery contains substances that may pollute
the environment. Always remove the battery before you discard and
hand in the appliance at an ofcial collection point. Dispose of the battery at an ofcial collection point for batteries. If you have trouble
removing the battery, you can also take the appliance to a Philips service centre. The staff of this centre will remove the battery for you and will dispose of them in an environmentally safe way.
Removing the rechargeable battery
1 Disconnect the appliance from the adapter. Let the appliance operate
until the battery is completely empty.
2 Remove the epilating head and open the appliance with a
screwdriver.
3 Insert the screwdriver into the small slot in the printed circuit board
marked with an arrow (1). Push the screwdriver down until parts of the printed circuit board break off (2).
ENGLISH 13
4 Pry the battery out of the appliance with the screwdriver.
Caution: Be careful, the battery strips are sharp.
Do not attempt to replace the rechargeable battery.
Do not connect the appliance to the mains again after you have removed the rechargeable battery.
Guarantee and service
If you have a problem, need information or replacement parts or if you want to purchase additional parts, please visit the Philips website at www. philips.com/support or contact the Philips Consumer Care Centre in your
country. You nd its phone number in the worldwide guarantee leaet. If
there is no Consumer Care Centre in your country, go to your local Philips dealer.
Loading...
+ 29 hidden pages