Steam Iron
HI 272
HI 274
Philips Domestic Appliances and Personal Care
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
PRODUCT INFORMATION |
|
|
|
|
||
Features |
|
HI 272 |
HI 274 |
|||
Pilot light |
|
|
x |
x |
||
Integrated cord winder |
|
|
x |
x |
||
Spray |
|
|
x |
x |
||
Shot of steam |
|
|
x |
x |
||
Self-clean |
|
|
x |
x |
||
Length cord set 2.5 m |
|
|
x |
x |
||
Soleplate coated |
|
|
x |
- |
|
|
Soleplate stainless steel |
|
|
- |
x |
||
Voltage / frequency |
: 220 |
- 240 V, 50-60 Hz |
|
|
|
|
|
110 |
- 127 |
V, 50-60 Hz |
|
|
|
Power consumption : 220 |
- 240 |
V → 1325 Watts |
||||
|
110 |
- 127 |
V → 1200 Watts |
Soleplate temperature with dial at max. position : 215 ± 25 °C
Self-clean function :
The self-clean function is operated by the steam dial. When this dial is turned to the correct position, a sudden flow of cold water is released from the tank into the heated soleplate. This thermal shock will cause scale particles to break loose from the steam chamber. These particles are then flushed out through the steam vents by the water.
This product meets the requirements regarding interference suppression on radio and TV.
Published by Philips Domestic Appliances and Personal Care |
Printed in the Netherlands |
© Copyright reserved |
Subject to modification |
4822 729 21819 97/04
PCS 88 665
DISASSEMBLY ADVICE
BACKPLATE 3
CORD SET 4
SWIVEL 5
remove SCREW A 2x remove BACKPLATE 3
INLAY/LAMPCOVER 6
PILOT LIGHT 7
DIAL THERMOSTAT 9
RATTLE SPRING 11
DIAL LINK 12
turn DIAL 9 on max position remove SCREW A 2x remove BACKPLATE 3 remove SCREWS cordset/
pilot light
remove SCREW B lx |
remove INLAY 6 |
DIAL HOLDER 10
SPRAY UNIT 13
PUMP/SPRAY UNIT 14
remove SCREW A 2x remove BACKPLATE 3 remove SCREWS cordset/ pilot light
remove SCREW B lx remove INLAY 6 remove SCREW 22
HANDLE 15
WATERTANK 16
remove SCREW A 2x remove BACKPLATE 3 remove SCREWS cordset/
pilot light/pcb remove SCREW B lx remove INLAY 6 remove SCREW 22
remove DIAL HOLDER 10 remove PUMP/SPRAY
UNIT 14 remove SCREW C 2x
COVER 18
TYPEPLATE 19
SOLEPLATE 21
THERMOSTAT 20
remove SCREW A 2x remove BACKPLATE 3 remove SCREWS cordset/
pilot light/pcb remove SCREW B lx remove INLAY 6 remove SCREW 22
remove DIAL HOLDER 10 remove PUMP/SPRAY
UNIT 14 remove SCREW D 3x
Replacement Thermostat see fig.1-4
REASSEMBLY ADVICE + PARTS LIST
REASSEMBLY ADVICE
When reassembling the iron, make sure that :
*Thermostat bush ( 17 ) is set to the position illustrated in fig A.
*Dial Link ( 12 ) and Dial Thermostat 9 are set to the positions, illustrated in fig B.
PARTS LIST
Pos |
Description |
Service Code |
|
|
|
1 |
dosing unit |
4822 360 10142 |
2 |
cord clip |
4822 401 11193 |
3 |
cord winder/backplate |
4822 441 12002 |
4 |
cord set Euro plug |
4822 321 10951 |
|
cord set UK plug |
4822 321 10952 |
|
|
|
|
cord set UL plug |
4822 321 10947 |
|
cord set “China plug” |
4822 321 11317 |
5 |
swivel |
4822 325 80505 |
6 |
inlay + lampcover 109 |
4822 310 11004 |
7 |
pilot light 220 - 240 V |
4822 134 20334 |
|
pilot light 110 - 127 V |
4822 134 20335 |
9 |
dial thermostat |
4822 412 40262 |
10 |
dial holder + spring 11 |
4822 256 10379 |
11 |
rattle spring |
4822 492 32876 |
12 |
dial link |
4822 535 93498 |
|
|
|
13 |
spray unit |
4822 360 60291 |
14 |
pump/spray unit incl. item 13 + 106 |
4822 360 10321 |
15 |
handle unprinted |
4822 498 10657 |
16 |
tank + stopper 102/H1272 and sealing 103 |
4822 310 11006 |
17 |
thermostat bush |
4822 532 61258 |
18 |
cover |
4822 442 00973 |
19 |
type plate unprinted |
4822 452 10337 |
20 |
thermostat |
4822 282 30229 |
21 |
sole plate 220 - 240 V incl. item 20 + 104 |
4822 259 10263 |
|
sole plate 110 - 127 V incl. item 20 + 104 |
4822 259 10262 |
|
|
|
22 |
long tapping screw |
4822 502 21315 |
23 |
kit sealings item 101 - 107 |
4822 310 11007 |
|
|
|
PCS 88 666