Philips HI204 Service Manual

Steam Iron
HI204
Philips Domestic Appliances and Personal Care
Service Manual
PRODUCT INFORMATION
Features
- Self clean function
- Steam output (15 grams/min)
- Water tank capacity 170 ml
- Cord length 1.9 m.
Safety Information
- This product meets the requirements regarding interference suppression on radio and TV.
- After the product has been repaired, it should function properly and has to meet the safety requirements as officially laid down at this moment.
TECHNICAL INFORMATION
Voltage : 100 - 127 V,
220 - 240 V
Frequency : 50 - 60 Hz
Power consumption : 1200 W
Dimension (F-box) : 272 x 112 x 140 mm Weight (Iron) : 1100 grams
Self Clean
When the self clean button is pushed, a sudden fl ow of water is released from the tank into the soleplate. This thermal shock will cause water scale particles to come loose from the steam chamber. These particles are then fl ushed out through the steam vents by the water.
Published by Philips Domestic Appliances and Personal Care Printed in the Netherlands © Copyright reserved Subject to modification
03/05
DISASSEMBLY ADVICE
PARTS LIST
HI204
CORD SET 5
PILOT LIGHT COVER 9
PILOT LIGHT 10
remove DOSING UNIT 1 remove screw A (2x) remove screw B (1x) remove INLAY 4 remove screw C (2x) (cord clamp)
TANK SET 11
remove DIAL 7
Pos Service code Description Consist of
1
10 11
12 13
14
4239 021 01300
2
4239 020 94210 4239 020 93470
3
4239 015 52140
4
4239 026 12670
4239 015 35520
5
4239 000 09040 4239 000 08790 4239 000 08810 4239 000 08890
6
4822 325 10226
7
4239 021 15480 4239 021 09980
8
4239 014 53790
9
4239 026 00880
4822 134 10133 4239 021 15470 4239 021 14740 4239 026 12570 4822 532 12722
4239 026 12580
Dosing unit Soleplate unit 100 - 127 V Soleplate unit 220 - 240 V Cover seal Inlay
Inlay (France) Cordset EU Cordset Argentina Cordset Italy Cordset Mexico
Swivel Dial (English/Spanish/Portuguese text) Dial (French/Dutch text) Rattle spring Pilot light cover
Pilot light Tank set 101 Tank set (France) Cover Isolation stud
Thermostat bush
remove screw D (2x)
COVER 12
SOLEPLATE 2
ISOLATION STUD 13
remove screw E (3x)
N
RESISTOR
INPUT
LAMP
FUSE
L
E
THERMOSTAT
HEATING UNIT
REPAIR INSTRUCTIONS
- In case of any defect in the thermostat, the complete soleplate has to be replaced.
- No information about the type number and voltage has been stamped into the type plate spare part. When replacing the typeplate, engrave at least type number and voltage into the type plate with a tool.
- The Comfort irons have been upgraded from “1-steam setting” to “2-steam setting”. Tank set (Pos 11), inlay (Pos 4) & dosing unit (Pos 1) are modified. The differences can be distinguished from the printing of dosing unit. In case a “1-steam setting” iron needs to replace either tank set, inlay or dosing unit, the 3 items have to be replaced together under the service codes in parts list.
1-steam setting
2-steam setting
2-3