Philips HI 124, HI 126, HI 120 Service Manual

Service Information
!
Philips Domestic Appliances and Personal Care
PRODUCT INFORMATION
Irons
HI 120 HI 124 HI 126
HI 120 HI 124 HI 126
colour white x x -
colour red - - x
sole plate linished x - -
pilot lamp x x x
spray unit x x x
Voltage / frequency : 220 - 240 V, 50 - 60 Hz
: 110 - 127 V, 50 - 60 Hz
Power consumption : 900 - 1100 Watts
Product meets the requirements regarding interference suppression on radio and TV.
Published by P hilips Domestic Appliances and Personal Care Printed in the Netherlands
4822 729 21694 96/08
PCS 87 779
©
Copyright reserved Subject to modification
ASSEMBLY ADVICE PARTS LIST HI 120 / HI 124 / HI 126
CORDSET 5
remove SCREW A remove BACK PLATE 101
remove SCREW A remove BACK PLATE 101 remove SCREW B 3x remove CORDSET 5 remove INLAY 8
SOLE PLATE 1
THERMOSTAT 3
INSOLATION
STUDS 3
LAMP 4
remove DIAL 102
remove SCREW C 3x remove HANDLE 104
INLAY 8
RELEASE
MECHANISM 9
remove SCREW A remove BACK PLATE 101 remove CORDSET remove INLAY 8
NOTE:
After the product has been repaired, it should function properly and has to meet the safety requirements and legal regulations as laid down and officially established at this moment.
ADJUSTMENT AND CONTROLS
Thermostat 3
Thermostat ( 3 ), fitted to sole plate ( 1 ) has already been adjusted by the supplier and secured by glue. To avoid disfunction of the iron, NEVER readjust the thermostat.
POS. DESCRIPTION SERVICE CODE
1 SOLE PLATE 110 - 127 V (incl. pos. 3) 4822 259 10209
SOLE PLATE 220 - 240 V (incl. pos. 3) 4822 259 10211
2 INSOLATION STUDS 4822 532 12722
3 THERMOSTAT 4822 282 10298
4 PILOT LAMP 100 - 240 V 4822 134 10055
5 CORDSET EURO PLUG 4822 321 10951
CORDSET UK PLUG 4822 321 10952
CORDSET UL PLUG 4822 321 10947
6 SPRAY UNIT + WATER TANK (7), 4822 360 10234
COLOUR WHITE
SPRAY UNIT + WATER TANK (7), 4822 360 10235 COLOUR RED
7 WATER TANK 4822 418 10213
8 INLAY, COLOUR WHITE 4822 442 00623
INLAY, COLOUR RED 4822 442 00624
9 RELEASE MECHANISM 4822 417 11329
NOTES: For standarisation reasons:
only the coated sole plate will be supplied for those types,
*
which are suitable for 220 - 240 V. only the linished sole plate will be supplied for those types,
*
which are suitable for 110 - 127 V. only the release mechanism with red operation push
*
button will be supplied. only cordsets with a length of 2.6 m will be supplied.
*
the colour of the cordset may differ from the original colour.
Parts, with numbers from 100 and higher, cannot be ordered separately.
Adjustment Thermostat 3, supplied as a spare part.
Connect the connecting strips to an Ohm meter. Set the vertical slot of the thermostat bush to the 11 o’clock position ( see picture ). Turn the adjusting screw clockwise or anti-clockwise until the Ohm meter indicates “0". ( the contacts are closed ) Then turn the adjusting screw clockwise until the Ohm
meter indicates . ( the contacts are open )
While free turning the thermostat bush, check if the thermostat switches in the 11 o’clock position. Secure the adjusting screw by glue. After adjusting the thermostat, always check the temperature of the soleplate, with the dial set on the MAX. position. ( 220 ± 20 °C )
Loading...