Coffeemaker “Cafe Gourmet II”
HD 5400/B
Philips Domestic Appliances and Personal Care
Service Manual 4822 729 21991 and Service Information
DAP 187, 4822 729 22086 are herewith cancelled.
Service Manual
GENERAL INFORMATION
In this coffeemaker the brewing process differs somewhat
from that in the Cafe Gourmet HD5560 coffeemaker. After
actuating the main switch S1 (item 10/11) the water in
container 33 starts to heat up, because thermostats T1 and
T2 are switched on (item 23 and 31).
After the boiling point has been reached, sensor-spring 19
expands and pushes rod 20 downwards. The hot water fl ows
along thermostat T1 and rubber valve 24, into fi lter 1.
When all the hot water has passed, thermostat T1 has been
heated up and has switched off the heating element.
The function of thermostat T2 (item 31) is only to limit the
temperature of the heating element.
To start the process again, cold water must be poured via
lid 28, along sensor 19. This sensor will close valve 24 and
thermostat 23 will cool down immediately and switch on the
element.
PRODUCT INFORMATION
Voltage : 100, 120, 220 - 240 V
Frequency : 50 - 60 Hz
Power consumption : Heating element 1250 W
PTC-element 50 W
Coloursetting : Black
Tank/jug capacity : 1000 cc
SERVICE INFORMATION
Thermostat T1 : 75°C
Thermostat T2 : 140°C
Fuse cut-off temp. : 192°C
This product meets the requirements regarding interference suppression on radio and TV.
S1
REPAIR INSTRUCTION
1. De-scaling
In case the valve system is nearly or less clogged by scale,
operate the coffeemaker two times with a 10-15% solution of
vinegar, citric or tartar acid.
Do not use other de-scaling agents as they may harm
the appliance.
In addition to this operation it is recommended to clean the
inside of the glass tank with a acid-soaked cloth. After the
de-scaling procedure, operate the coffeemaker with tap
water to rinse away any residual substances.
2. Exchanging rubber valve item 24
To get some room simply push rod 20 downwards at place A.
Now the small rubber valve can be removed and a new be
fi xed.
After the product has been repaired, it should
function properly and has to meet the safety
requirements as offi cially laid down at this
moment.
SAP coding HD 5400/B
T1
PTC
T2
E