Philips HB 975-A Service Manual

5 (1)

HPA Solarium

HB 975/A

Sun &

Relaxmobile

Domestic Appliances and Personal Care

 

 

 

 

 

 

 

 

 

 

 

 

TECHNICAL DATA

 

 

 

Input voltage

: 230V - 50Hz

Input consumption

: approx. 2550W

Fuse

: 16 A

UVA source

: 4x HPA Flexpower 400-600

Ballast

: 2x 400W

 

: 2x 500W

Starter

: integrated soft start system

Timer

: digital 30 mins

Cooling

: 1x fan floor part

 

: 3x fan tanning part

Radiation area

: 190 x 70 cm

Output (min) UVX-36 meter : 4.2 mW/cm2 at 65 cm

in centre facial unit

 

 

 

Protecting goggles

: 2x HB072 - 4822 690 80147

Safety

: CENELEC insulation class 2

 

: UV type 3

Weight

: approx. 45 kg

AS THE APPLIANCE IS HIGHLY SUSCEPTIBLE TO SCRATCHING, YOU SHOULD BE EXTRA CAREFUL DURING DISASSEMBLY.

TO PREVENT THE MULTI-CORE CABLES FROM GETTING DAMAGED AT THE HINGES, THEY MUST BE ASSEMBLED AND CLAMPED AT THE ORIGINAL PLACES.

Published by Philips Domestic Appliances and Personal Care

Printed in The Netherlands

© Copyright reserved

Subject to modification

4322 277 00911 02/01

Philips HB 975-A Service Manual

 

L

 

 

Tr1

C2

 

C1

 

 

 

C4

 

C2

 

C3

 

 

Tr2

C1

 

 

 

 

 

C3

 

L

M1

C4

 

 

Tr3

 

 

N

 

 

 

 

 

 

 

 

 

IR

 

 

 

 

 

 

 

Tr4

 

 

 

B1

NC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IR1

TCO2

SK2

M2

 

Tr5

 

 

 

B9

L1

 

 

 

 

 

La

 

 

 

 

 

 

 

C7

L6

B7

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Tr6

 

 

 

B8

L2

 

 

 

 

 

 

 

 

 

La

SK5

SK3

 

 

 

 

C8

L7

B6

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Tr7

 

 

 

B3

L3

 

 

 

M3

 

 

 

 

 

La

 

 

 

 

 

 

 

C9

L8

B5

3

SK6

 

TCO3

 

 

 

 

 

 

 

 

 

 

M4

 

 

 

B2

L4

 

 

 

 

L

Tr8

 

 

 

 

La

 

 

 

 

 

 

C10

L9

B4

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

M3

 

 

 

 

IR

TCO4

 

SK4

M4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IR2

 

 

 

 

 

C

 

TCO1

 

 

 

 

 

 

 

 

R9

R7

R8

 

 

 

 

 

 

 

 

 

 

 

N

N

 

 

 

 

 

 

 

 

 

 

 

 

 

R5

R10

 

 

 

 

 

 

 

 

 

C11

 

 

 

C12

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R6

 

 

 

safety

Re1

 

 

 

 

 

T1

 

 

 

 

 

 

 

 

 

N

M2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

M1

 

 

 

 

 

 

 

 

 

TECHNICAL INFORMATION

Tanning appliance HB975 is equipped with a universal power PCB.

This means that the specific characteristics of the appliance have to be programmed in a microcontroller to determine the way in which various components are activated.

When the mains plug is inserted into the wall socket, the display of the remote control will show all functions available to the user.

Including the various combinations, these functions are:

time setting

full body tanning

half body tanning

relax session

The UV lamps may produce a humming sound just after start-up. This humming sound will stop as soon as the lamps burn properly, which is after about

20 seconds. At this point the light intensity clearly increases.

During the last minute of the session the beeper produces an intermittent signal to alert the user to the fact that a new session can be set.

After pressing the key, the display showing and, the UV working hours will be shown. After 750 operating hours, an L will automatically appear on the

display to indicate that the HPA lamps need to be replaced or the tanning time must be slightly increased.

The clock speed of the µ-controller is derived from the 50 Hz mains frequency.

This frequency is also used to control the 8 triacs that determine the switch-in point (soft start) of the cos ! capacitors and the HPA and IR lamps.

The fans are switched via the safety relay.

This relay is part of the (one fault condition) timer circuit.

If the control of the triacs is disturbed due to a fault in the µ-controller, the UV lamps may not be switched off.

As the µ-controller also generates a pulsating direct voltage to power the relay, the relay will be de-energised in case of a fault, thereby interrupting the lamp circuit.

Conversely, the appliance will not start if the switch contacts of the relay are closed at that moment (sticking contacts).

The remote control is galvanically isolated from the mains, with power supply and control taking place via a 4-core cable.

The remote control only functions as input/output terminal.

The IR lamps are started by means of the conventional phase cut-in principle and burn at full power after about 8 seconds.

DISASSEMBLY

1. FLOOR PART (item 37)

-Remove the cord holders (item 28) and detach the cord clamps at the back.

-Remove the covers (item 29 and 39).

The cover on the flex side can only be removed last.

2. REMOTE CONTROL (item 41)

-Remove the cord holder and pull the connector loose.

3. WHEEL (item 49)

-Remove the covers (item 29,39).

-Remove the locking plate and the nearest frame screw.

-Push the shaft out of its clamping.

4. GAS SPRING (item 14)

-Remove the covers (item 29,39).

-Put the appliance in its highest operating position (to ensure that no pressure is excerted on the gas spring) and tighten the ornamental screw (item 26).

-Loosen the 10-core cable so that the cable can easely slide through the cable duct.

-Remove a retaining ring from the hinge shaft at A.

-Tilt the appliance carefully so that the radiation part rests on the floor.

-Support the floor part to remove the pressure from the hinge shaft.

-Remove the hinge shaft and lower the floor part onto the floor.

-Remove the 2 bearing bushes.

-Loosen the ornamental screw (item 26), slide the top part of the stand approx. 20 cm inwards and tighten the screw again.

-Remove the 2 screws from the upper part of the stand at B and pull this part loose from the hinge.

-After the shafts have been removed, the gas spring can be slid out of the stand.

5. HIGHT ADJUSTMENT (item 27)

-Loosen the lower attachment of the gas spring in the manner described under 4.

-Remove the cord with its clamping by pressing the snap clamping on the inside.

-Remove the outer tube.

-Remove the 2 guide blocks and slide the

clamping block from the inner tube.

6.HINGE WITH GAS SPRING (item 12) - Remove the stand part in the manner

described under 4 and 5.

- Remove the upper ornamental strips from the hinge part.

- Remove the cover (item 17) from the radiation part.

- Remove the cover from the connector compartment.

- Detach the 10-core cable.

- Remove the retaining ring from the locking shaft at C and push the shaft out of the stand.

- Remove the hinge part.

7.HPA LAMP (item 23) or IR LAMP (item 23A) - Remove the glass filter from the lamp unit in

question.

The lamp unit will continue to cling to the upper part.

- Remove the reflector clamps.

- Remove the reflector and take the lamp from the holder.

NB: When checking or replacing HPA lamps, pay attention to the following:

a.HPA lamps only start burning when they have cooled down sufficiently.

b.Never touch a lamp with your fingers. Clean the lamp with a cloth moistened with alcohol, if necessary.

c.After assembly the glass filter should be free from finger prints and dust. Clean the glass filter with a cloth moistened with alcohol, if

necessary.

8. COVER OUTER SECTION (item 19)

-Remove the cover (item 17) and the cover of the connector compartment.

-Detach the wires of the outer section.

-Support this section and remove the 3 fixing screws at D.

9. COVER INNER SECTION (item 1)

- Disassembly of the cover is not advisable, since the non-visible parts of the pivot can only be fitted with special tools.

For this reason, the cover is supplied as a whole with grip plate and wiring.

-Remove the centre glass filter and assemble it onto the new cover.

-Remove the outer sections (see under 8) and attach them to the inner section.

-Detach the wiring that runs through the tube of the stand.

-Remove the upper ornamental strips.

-Remove the retaining ring from the locking shaft at C and push the shaft out of the stand.

-Pull the inner section out of the stand.

10. POWER PCB (item 30)

-Pull the mains plug out of the wall socket.

-Remove the cover (item 29, see under .1)

-Replace the power PCB and connect all connectors.

-Place the cover on the base. The display of the remote control will now show error code E06 or E05.

-This indicates that the power PCB still needs to be programmed (code A09) for use in the HB975 according to the input in the table.

The following fault codes have been defined:

E01 - Safety circuit interrupted

This code will appear on the display for 5 seconds, while the beeper produces a loud beep.

Check whether the lamp units are in the correct position, whether all fans work or whether any UV filter is missing, broken or damaged.

E02 - Safety relay does not work according to specification

Replace the power module (item 30).

E03 / Fault in microprocessor

E04 - Replace the power module (item 30).

E05 / Application code not programmed E06 - This only occurs in case of a new

power module supplied by Service. Program the application code, beginning at line 1, step 3.