Domestic Appliances and Personal Care |
|
|
|
|
|
|
|
|
|
COMBI SOLARIUM
The introduction of different inrush current limiting components as from production code 0101 has resulted in a type number change into HB545/B and into HB546/B, see diagram below.
-t |
NTC |
|
|
L |
M |
C |
La |
S |
M |
|
|
|
|
|
|
4x |
10x |
|
Couch |
|
|
L |
L |
|
|
|
|
S |
S |
|
|
|
|
M |
M |
La |
S |
|
|
|
10x |
|
2xHB 546 |
Canopy |
A burned NTC resistor or overheated wiring points to a wiring fault at the connecting block.
The correct wiring is shown below.
BROWN |
|
BROWN |
|
BLACK |
BLACK |
BLACK |
BLACK |
BROWN |
BROWN |
NTC |
NTC |
NTC |
NTC |
The newly introduced parts are:
4222 062 94580 NTC resistor 22Ω
4222 062 94600 capacitor 50µF/250V
4222 062 94570 connecting block 8 sections