Philips HB546-B, HB546-A, HB545-B, HB545-A Service Manual

0 (0)
Philips HB546-B, HB546-A, HB545-B, HB545-A Service Manual

Service

 

 

 

2001-08-17

 

 

 

 

 

HB545/A

HB545/B

Information

 

HB546/A

HB546/B

 

 

 

 

 

 

 

 

 

 

 

DAP 326

 

 

 

 

 

Domestic Appliances and Personal Care

 

 

 

 

 

 

 

 

 

COMBI SOLARIUM

The introduction of different inrush current limiting components as from production code 0101 has resulted in a type number change into HB545/B and into HB546/B, see diagram below.

-t

NTC

 

 

L

M

C

La

S

M

 

 

 

 

 

4x

10x

 

Couch

 

 

L

L

 

 

 

 

S

S

 

 

 

 

M

M

La

S

 

 

 

10x

 

2xHB 546

Canopy

A burned NTC resistor or overheated wiring points to a wiring fault at the connecting block.

The correct wiring is shown below.

BROWN

 

BROWN

 

BLACK

BLACK

BLACK

BLACK

BROWN

BROWN

NTC

NTC

NTC

NTC

The newly introduced parts are:

4222 062 94580 NTC resistor 22Ω

4222 062 94600 capacitor 50µF/250V

4222 062 94570 connecting block 8 sections

4322 277 00693

Loading...