Service
Service
Service
Table solarium
HB 172/A
55
60 MIN
5 0
5 1
45
03 25
20
Philips Domestic Appliances and Personal Care
GENERAL
This solarium is especially intended for the tanning of the face. The UVA-source consists of 2x2 series connected TL’s.
The radiation distance is 10 cm or less.
In connection with this small distance the advice is to wear protecting goggles during the cure.
HINTS FOR REPAIRS
-After the screws (item A) have been loosened the cover (item 1) can be removed.
-Starter(s) and lamp(s) can be replaced now.
If one lamp or starter is defective 2 lamps will not burn because of the series connection.
By changing it can be found which lamp or starter is defective.
-When the reflector has been removed the internal wiring can be checked.
-For the replacement of a ballast the tubular staple must be drilled out.
The new ballast can be fastened with a M4 bolt and nut.
SAP coding HB 172
LA1 |
LA2 |
|
LA3 |
LA4 |
S1 |
S2 |
|
S3 |
S4 |
L1 |
|
|
60 MIN |
N |
|
|
|
|
|
|
|
|
|
L |
L2 |
|
|
|
|
TECHNICAL DATA |
|
|
|
|
Input |
|
: |
75W |
|
UVA-source |
|
: 4 x TL CLEO 15W |
||
Radiation area |
|
: 20 x 26 cm |
|
|
Radiation distance |
: |
10 cm |
|
|
Starter |
|
: |
4 x S2 |
|
Ballast |
|
: |
2 x 30W |
|
Timer |
|
: |
60 min./Diehl |
|
Protecting goggles |
: |
4822 690 80072 |
|
|
Output UVX36 meter |
: |
>3.4mW/cm2 |
|
Published by Philips Domestic Appliances and Personal Care Printed in The Netherlands © Copyright reserved Subject to modification
4322 277 00354
00/06