Philips GC 6007 Service Manual

Page 1
Provapor excel pro
GC 6007
Service Information
!
Philips Domestic Appliances and Personal Care
Service Manual
SAP coding GC 6007
PRODUCT INFORMATION
Feataures : careeza sole plate boiler capacity 1 litre length steam hose 1,9 metre length cord set 1,9 metre maximum steam output 80 gr/min steam ready indicator boiler empty indicator shot of steam front steam variable steam
Voltage : 220-240 Volt Frequency : 50-60 Hz
Power consumptium : Boiler : 1200 Watt Pressure : 3,5 bar Iron : 800 Watt
Product meets the requirements regarding interference suppression on radio and television.
- After the product has been repaired, it should function properly and has to meet the safety requirements as laid down offi cially established at this moment.
Published by Philips Domestic Appliances and Personal Care Printed in the Netherlands © Copyright reserved Subject to modification
4322 277 00519 01/04
Page 2
DISASSEMBLY ADVISE IRON
DIAL 1
RATTLE SPRING 11
BACK PLATE 2
remove SCREW A remove CORD CLAMPING remove SCREW (2x) remove CONNECTIONS remove HOSE
INLAY 4
CONTROL BUTTONS 6
SPRAY NOZZLE 7
PILOT LIGHT 10
SLIDE UNIT 9
remove SCREW B (2x)
Replacement Thermostat see fi g.1-4
HANDLE 10
remove SCREW C (3x)
STEAM CONTROL
ASSY 19
remove SCREW D remove SWITCH
HOUSING 15 remove JOS ACTUATOR
ASSY 7 remove SOS ACTUATOR
ASSY 13
SKIRT (HB) 12
remove SCREW F (3x)
NOTES :
- For standardisation reasons : Dial (1) : Dutch / French language only Suction tubes stand : Only 27 cm long tubes will be supplied Rattle spring (11) : 5 pieces will be supplied when ordered
For opening you need a Torx screwdriver 362 TR T20 x 100.
STAND IRON
Main switch
Steam ready
Boiler thermostat
Boiler heating element
Cut out
Electro-
valve
Steam­switch
Dry
p
lamp
Thermostat
Page 3
PARTS LIST + EXPLODED VIEW IRON
Pos DescriptionService Nummer
Kit dial Kit backplate Kit swiveI Inlay printed assy Lamp assy
Kit knobs JOS actuator assy Dosing assy Kit slide unit Kit handle
Rattle spring (5x) Skirt (HB) SOS actuator assy Microswitch assy Switch housing
Kit tubes Dosing housing welded Kit sealings Steam control assy Baseplate 2
Soleplate mtd assy Type plate Lamp holder Thermostat bush Thermostat
Pin thermostat26 4822 535 10469
10 11
12 13 14 15
16 17 18 19 20
21 22 23 24 25
1 2 3 4 5
6 7 8 9
4822 310 11417 4822 310 11418 4822 310 11157 4822 442 01896 4822 134 10146
4822 310 11421 4822 360 10459 4822 690 10225 4822 310 11422 4822 310 11423
4822 310 11021 4822 442 01807 4822 360 10461 4822 277 11884 4822 441 12368
4822 310 11424 4822 441 12369 4822 310 11425 4822 690 10226 4822 464 10531
4822 259 10331 4822 454 13475 4822 256 10582 4822 532 13161 4822 282 10315
4
6
9
19
B
8
2
5
3
23
10
1
11
C
C
Z
Page 4
D
15
14
13
6
Z
X
16
24
19
E
17
7
18
20
C
2
3
F
F
A
F
12
22
18 18
13
X
18
21
2526
DAP0991
Page 5
EXPLODED VIEW STAND
34
36
33
32
E
41
37 35
38
40
37
39
43
46
42 45
44
47
DAP1576
Page 6
PARTS LIST + DISASSEMBLY ADVICE STAND
Pos Service Nummer
32 33 34 35 36
37 38 39 40 41
42 43 44 45 46
9965 000 08193 9965 000 08194 9965 000 08244 9965 000 01782 9965 000 08245
4822 462 71999 9965 000 08243 9965 000 08201 9965 000 08202 9965 000 01790
9965 000 08203 4822 218 11561 9965 000 01901 9965 000 01902 9965 000 07437
Description
Tray rubber foot for fi xation Complete tray Safety cap for boiler Filling hole gasket for alu boiler Superior stand printed
Boiler rubber feet Complete boiler Locket insert Inferior stand Filter
Main switch Electrovalve Steam ready light Boiler empty light Intermediate cable
47 9965 000 08246 Funnel
ADJUSTMENT AND CONTROLS
– To avoid leakage of the sealings and damage to
the components in and on the boiler, NEVER clean the boiler with vinegar, a descaling agent or other chemicals.
OPEN THE STAND
pressure fi xation rubber through the tray
E
remove SCREW E (3 x)
E
E
– The boiler doesnt contain serviceable parts.
Never disassemble the boiler body and /or compo­nents on and in the boiler.
– ALWAYS REPLACE THE BOILER ( 28 ) WHEN:
the mechanical safety valve ( 24 ) has been acti-
*
vated.
the boiler thermostat or hand - resettable safety
*
thermostat are open, because the boiler has been subjected to too high temperatures.
the electrovalve ( 33 ) fails or the sieve is soiled
*
with scale.
– After the product has been repaired, it should func-
tion properly and has to meet the safety require­ments as laid down and offi cially established at this moment.
remove LOCKED INSERT 39
NOTE: OPEN NOW THE STAND. DONT WORRY IF THE SNAPS AT THE SIDE WILL BE BROKEN. THEY ARE ONLY FOR THE ASSEMBLY. THE STAND REMAINS CLOSE WITHOUT THESE SNAPS.
Loading...