Philips GC1515 Service Manual

Steam Iron
GC1515
Philips Domestic Appliances and Personal Care
Service Manual
PRODUCT INFORMATION
Features
- Spray feature
- Self clean function
- Steam output (15 grams/min)
- Water tank capacity 170 ml
Safety Information
- This product meets the requirements regarding interference suppression on radio and TV.
- After the product has been repaired, it should function properly and has to meet the safety requirements as officially laid down at this moment.
TECHNICAL INFORMATION
Voltage : 220 ~ 240 V Frequency : 50 ~ 60 Hz
Power consumption : 1200 ~ 1440 W
Dimension (F-box) : 272 x 112 x 140 mm Weight : 1100 grams
Self Clean
When the self clean button is pushed, a sudden fl ow of water is released from the tank into the soleplate. This thermal shock will cause water scale particles to come loose from the steam chamber. These particles are then fl ushed out through the steam vents by the water.
3
Published by Philips Domestic Appliances and Personal Care Printed in the Netherlands © Copyright reserved Subject to modification
03/03
DISASSEMBLY ADVICE
PARTS LIST
GC1515
CORD SET 5
PUMP 2
PILOT LIGHT COVER 9
PILOT LIGHT 10
remove DOSING UNIT 1 remove SPRAY KNOB 3 remove screw A (2x) remove screw B (1x) remove INLAY 4 remove screw C (2x) (cord clamp)
TANK SET 11
remove DIAL 7
Pos Service code Description
1 2 3 4 5
6 7 8 9
10
11 12 13 14 15
16 17
4239 021 17260 4239 020 90560 4239 026 14290 4239 015 35790 4239 000 06800
4239 026 14300 4239 021 17250 4239 014 53790 4239 026 00880 4239 020 92720
4239 021 17240 4239 026 00850 4239 015 70150 4239 026 12360 4239 021 17230
4239 015 52140 4239 015 54210
Dosing assembly Pump Spray knob Inlay (spray feature) Cord set
Swivel Dial Rattle spring Pilot light cover Pilot light
Tank set (spray feature) Cover Isolation stud Thermostat bush Soleplate assembly
Cover seal Tank top seal
N
remove screw D (2x)
INPUT
COVER 12
SOLEPLATE 15
L
ISOLATION STUD 13
E
remove screw E (3x)
REPAIR INSTRUCTIONS
- In case of any defect in the thermostat, the complete soleplate has to be replaced.
- No information about the type number and voltage has been stamped into the type plate spare part. When replacing the type plate, engrave at least type number and voltage into the type plate with a tool.
RESISTOR
HEATING UNIT
LAMP
FUSE
THERMOSTAT
2-3
Loading...
+ 1 hidden pages