Philips GC 137 Service Manual

Dry Iron, Diva
GC 137
Philips Domestic Appliances and Personal Care
Service manual 4322 277 00480 is herewith cancelled.
Service Manual
PRODUCT INFORMATION
Features
- Aluminium soleplate
- Pilot lamp
- Full length button groove
- Integrated cord winder
TECHNICAL INFORMATION
Voltage/frequency : 100 V, 110-127 V, 220-240 V, 50-60 Hz
Power consumption : 900 W at 100 V
950-1100 W at 220-240 V
750-1000 W at 110-127 V
Soleplate
The Aluminium soleplate used is smooth and corrosion free which treats fabrics gently.
This product meets the requirements regarding
interference suppression on radio and TV.
Published by Philips Domestic Appliances and Personal Care Printed in the Netherlands © Copyright reserved Subject to modification
4322 277 00729 02/01
DISASSEMBLY ADVICE DRY IRON PARTS LIST DRY IRON
DIAL 1
RATTLE SPRING 6
INLAY 2
SWIVEL 3
Remove Screws A1 and A2
Description Consist ofPos Service code
Dial printed (Eng/Fre/Spa)
1. Inlay
2. Swivel
3. Cord set 220-240 V / 950-1100 W
4. Cord set 100 V / 900 W Cord set 110 V / 750 W Lamp
5. Rattle spring
6.
7.
Handle 101, 102
8.
Thermostat bush
9.
Soleplate Cover
10.
Insulator ring
11.
Soleplate assy 220-240 V / 950-1100 W 103 Soleplate assy 100 V / 900 W Soleplate assy 110 V / 750 W
4239 021 05120 4239 026 06960 4239 026 06980 4239 000 07140 4239 000 07930 4239 000 07150 4239 021 03880 4239 014 52700 9965 000 08985 4239 026 06220 4239 015 33490 4239 015 70150 4239 021 05660 4239 021 06440 4239 021 05600
CORD SET 4
LAMP 5
Remove Dial 1 Remove Rattle spring 6 Remove Screws A1 and A2 Remove Inlay 2 Remove Swivel 3 Remove Screws B1 and B2
HANDLE 7 (101, 102)
THERMOSTAT BUSH 8
Remove Dial 1 Remove Rattle spring 6 Remove Screws A1 and A2 Remove Inlay 2 Remove Swivel 3 Remove Screws B1 and B2 Remove Cord set 4 Remove Lamp 5 Remove Screw C
SOLEPLATE COVER 9
INSULATOR SUPPORT 10
Remove Dial 1 Remove Rattle spring 6 Remove Screws A1 and A2 Remove Inlay 2 Remove Swivel 3 Remove Screws B1 and B2 Remove Cord set 4 Remove Lamp 5 Remove Screw C Remove Handle 7 Remove Thermostat bush 8 Remove Screw D Remove Screws E1 and E2
NOTES :
After the product has been repaired, it should function properly and has to meet the safety requirements and legal regulations as laid down and offi cially established at this moment.
ADJUSTMENTS AND CONTROLS
Thermostat, 103
The thermostat, fi tted to soleplate 11 has already been adjusted by the supplier and secured by glue. To avoid disfunction of the iron, NEVER readjust the thermostat.
For standardisation reasons :
* Silverstone soleplate will be used for GC 147, GC 146 and GC 141. * Aluminium soleplate will be used for GC 130, GC 135 and GC 137. * GC 130 and GC 141 will not have the pilot lamp indication.
Parts, with numbers from 100 and higher cannot be ordered separately.
Loading...
+ 1 hidden pages