Philips GC1111 Service Manual

Steam Iron (LESI)
GC1111
Philips Domestic Appliances and Personal Care
Service Manual
PRODUCT INFORMATION
Features
- Ceralon / coated soleplate
- Tank capacity (150 ml)
- Integrated calc clean
- Steam rate (15 g/min)
Safety Information
- This product meets the requirements regarding interference suppression on radio and TV.
- After the product has been repaired, it should function properly and has to meet the safety requirements as officially laid down at this moment.
TECHNICAL INFORMATION
Voltage : 220 - 240 V Frequency : 50 - 60 Hz Power consumption : 1200 - 1440 W
Water advice
Suitable for tap water use. However if the tap water in your area is very hard, we advise you to mix it with a equal portion of distilled water or to use distilled water only.
Soleplate
Ceralon, the name indicates the strong combination of the of a non-stick coating (“lon”) blended with ceramic (“Cera”) particles. The soleplate is coated with Ceralon material which is smooth gliding, high scratch resistance and good durability advantage over the non stick coatings.
Calc clean
The integrated Calc clean function ensure a longer lifetime using normal tap water by removing the scale out of the steam chamber.
Published by Philips Domestic Appliances and Personal Care Printed in the Netherlands © Copyright reserved Subject to modification
03/09
DISASSEMBLY ADVICE
PARTS LIST
GC1111
BACKPLATE 3
LAMP ASSY 6
SWIVEL 7
CORDSET 8
INLAY 4
Remove Screw A (1x) Remove BACKPLATE 3 Remove LAMP ASSY 6 Remove SWIVEL 7 Remove CORD SET 8 Remove DOSING ASSY 1 Remove Screw B (1x) Remove INLAY 4
DIAL 2
TANK SET 5
THERMOSTAT BUSH 9
Pos Service code Description
1
10
11 12 13 14
4239 021 14550
2
4239 021 14540
3
4239 026 16450
4
4239 026 12090
5
4239 021 22350
6
4239 021 14520
7
4239 025 96960
8
4239 000 06720
4239 000 07140 4239 000 07030
9
4239 026 06220 4239 026 12070
4239 015 70150 4239 015 52140 4239 015 54210 4239 021 20840
Dosing assy (non extra steam) Dial printed Backplate Inlay (non spray)
Tank set (non spray) Lamp assy Swivel Cordset Thailand
Cordset Singapore Cordset Export Singapore Thermostat bush Cover
Isolation stud Cover seal Tank seal Soleplate assy
COVER 10
ISOLATION STUD 11
COVER SEAL 12
SOLEPLATE ASSY 14
Remove DIAL 2
Remove DOSING ASSY 1 Remove Screw B (1x) Remove INLAY 4 Remove Screw C (3x) Remove TANK SET 5 Remove THERMOSTAT BUSH 9 Remove Screw D 3(x) Remove COVER 10 Remove ISOLATION STUD 11 Remove COVER SEAL 12 Remove SOLEPLATE ASSY 14
N
220-240 V
THERMOSTAT
L
E
RESISTOR
LAMP
THERMAL
FUSE
HEATING UNIT
REPAIR INSTRUCTIONS
- For standardisation reasons, Cerelon coated soleplate will be supplied for GC1121, 1120, 1115, 1111, 1110 and Aluminium soleplate for GC1015, 1010, 1005.
- In case of any defect in thermostat, the complete soleplate has to be replaced.
- No information about the type number has been stamped into the type plate. When replacing the type plate, engrave at least type number and voltage onto the type plate with a tool.
OPTIONAL (accessories)
- No specific issues
2-3