Philips FC8426 Service Manual

City Line Geneva Vacuum cleaner
FC8426 /02 /A
Philips Domestic Appliances and Personal Care
Service Manual
- Colour: Anthracite
- Electronically controlled motor speed
- Built-in cord winder
- Dustbag-full indicator in dust cover
- This product meets the requirements regarding interference suppression on radio and TV.
- After the product has been repaired, it should function properly and has to meet the safety requirements as officially laid down at this moment.
TECHNICAL INFORMATION
- Maximum air displacement : 34 l/sec.
- Maximum vacuum water column : 260 cm
- Power consumption (IEC) 225V : 1500 W
- Dust storage capacity : 2 l
- Cord length (depends on version) : 6 m
- Filter system : 5 filters
- Dimensions of cleaner : 382 x 292 x 218 mm
- Dimensions of packaging : 510 x 305 x 330 mm
- Net weight : 4.5 Kg
- Gross weight : 8,0 Kg
- Noise : 79 dB
DISASSEMBLY- AND RE-ASSEMBLY ADVISE
- First lift and remove the knob and printed knob base and
then loosen mounting screws A.
AA
A
- Lift the motor housing (item 26) out of the lower housing
and take out the cord winder unit.
- To disassemble the cord winder, use TORX screwdriver no. T10, which is one of a set consisting of T20; T15; T10; T9; T8; T7 and T6 (code number 4822 395 50145).
OPTIONAL (accessories)
- FC8021 S-paper dustbags 8838 021 00000
- FC8032 Exhaust AFS micro filter 4822 015 70056
- HR6997 Sydney cotton dustbag 8836 997 01010
Published by Philips Domestic Appliances and Personal Care Printed in the Netherlands © Copyright reserved Subject to modification
03/08
REPAIR INSTRUCTION
- The spare parts have been standardized as much as possible.
- Cotton dustbags are used in countries where paper dustbags are unobtainable.
- If the reel half spring unit is replaced, shaft F must be lubricated with silicone grease. Do not apply any silicone grease to or spill any grease on terminals (36) or conductors (35).
- Item 34 is provided with a long cord-winder spring, but both long and short cords can be used in combination with this spring. (L = 9.3 m)
- Depending on the length of the original cord, the spare cord may have to be shortened.
- The cord winder spring must be tensioned to the maximum level and then be rewound approx. 1.5 turn.
- The RPM can be adjusted by means of the potentiometer mounted on the PCB (item 25). The RPM is correctly adjusted if the motor starts automatically and continues to run smoothly with the ON/OFF position and the adjustable potentiometer in minimum position.
- If the function of the electronic control unit (item 25) is not required, the Triac must be short-circuited in the manner shown in the circuit diagram.
- When the vacuum cleaner is used to suck up fine dust, the pores of the dustbag may become clogged, causing the passage of air through the dustbag to become obstructed. As a result, the dustbag-full indicator will indicate that the dustbag needs to be replaced, even though the dustbag is not full at all.
FC8426/02/A
ELECTRICAL DIAGRAM
MOTOR POWER
MODULE
Brown
Blue
Black
Black
CORD WINDER
Triac
M
Short-circuit
2-6