◗Only use Philips s-bag™ double-layer paper dustbags (FC 8021) or Philips Sydney+ double-
layer paper dustbags (type HR 6999).
◗Never use the vacuum cleaner to suck up water or any other liquid.Never pick up ashes until
they are cold.
◗When the vacuum cleaner is used to suck up fine dust,the pores of the dustbag may become
clogged,causing the passage of air through the dustbag to become obstructed.As a result,the
dustbag-full indicator will indicate that the dustbag needs to be replaced,even though the
dustbag is not full at all.
◗Never use the appliance without the Motor Protection Filter.This could damage the motor
and shorten the life of the appliance.
◗Never clean the appliance with water.
General description
1On/Off button
2Cordwinder button
3Opening dustcover
4Dustbag
5Hinging handle
6Opening filtercover
7Tapturn opening
8Front grip
9Dustbag full indicator
10 Turnknob (version FC8406 and FC8410)
11 Receiver unit (version FC8412)
12 Rearwheels
13 Castor wheel
14 Storage position
15 Small nozzle
16 Crevice tool
17 Small brush
18 Telescopic tube
19 Reach & Clean nozzle
20 Brush indications
21 Turning switch mechanism hard/soft floors
22 Parking ridge
23 Plug
24 Motor protection filter assy
25 Type plate
Page 7
26 Infrared remote control (version FC8412)
27 Bend with hose assy
28 Twist & Clean nozzle (version FC8410 and FC8412)
29 Twist & Clean polishing pads (version FC8410 and FC8412)
Connecting accessories
◗To connect the hose to the appliance,push it into the appliance and turn it clockwise (fig.1).
To disconnect the hose from the appliance, turn it anticlockwise and pull it out of the appliance.
Button coupling (specific types only)
1 Connect the tube to the handgrip by pressing the spring-loaded lock button on the handgrip
and inserting the handgrip into the tube. Fit the spring-loaded lock button into the opening in
the tube ("click") (fig.2).
◗To disconnect the tube from the handgrip,press the spring-loaded lock button and pull the
handgrip out of the tube.
◗Use the same method to connect and disconnect the other accessories.
Telescopic tube
◗Adjust the tube to the length you find most comfortable during vacuum cleaning (fig.3).
Reach & Clean nozzle
◗The Reach & Clean nozzle can be used on either carpets or hard floors.The nozzle can be
turned 360 degrees to 4 different positions,allowing you to also vacuum clean hard-to-reach
places in an easy way.When the nozzle is positioned lengthwise,the suction power is
concentrated at the front side of the nozzle (fig.4).
◗To adjust the nozzle to the type of floor and the area to be cleaned,put your foot on the
indicated spot and then turn the tube until the nozzle is in the required position (fig.5).
1 With the nozzle positioned breadthwise and the brush strip folded out,you can vacuum clean
large hard floor areas.Turn the tube until the brush strip pops out of the nozzle housing and
the nozzle is positioned breadthwise (fig.6).
2 With the nozzle positioned lengthwise and the brush strip folded out,you can vacuum clean
small hard floor areas.Turn the tube 90 degrees anti-clockwise until it is positioned
lengthwise with the brush strip still folded out of the nozzle housing (fig.7).
3 With the nozzle positioned breadthwise and the brush strip folded in,you can vacuum clean
large soft floor areas.Turn the tube 90 degrees anti-clockwise again to position the nozzle
breadthwise and to make the brush strip disappear into the nozzle housing (fig.8).
4 With the nozzle positioned lengthwise and the brush strip folded in,you can vacuum clean
small soft floor areas.Turn the tube 90 degrees anti-clockwise again until it is positioned
lengthwise with the brush strip still folded in (fig.9).
Crevice nozzle,brush nozzle and small nozzle
The crevice nozzle can be used either for cleaning narrow corners or hard-to-reach places.
1 Lift the handle on the vacuum cleaner to gain access to the accessory storage compartment
(fig.10).
2 Connect the crevice nozzle to the tube or directly to the handgrip.
3 The brush nozzle can be used for cleaning computers,bookshelves etc (fig. 11).
7ENGLISH
Page 8
8ENGLISH
4 The small nozzle can be used for vacuum cleaning small areas,e.g. the seats of chairs and
sofas (fig.12).
Vacuum cleaning
1 Pull the cord out of the appliance and put the mains plug in the wall socket (fig.13).
2 Switch the appliance on by pushing the on/off button on top of the appliance with your foot
(fig.14).
3 To carry the appliance, put the handle in upright position and lift the appliance by the handle
(fig.15).
Adjusting suction power
You can adjust the suction power during vacuum cleaning:
1 Adjust the suction power by means of the electronic suction power control (specific types
only) (fig.16).
Infrared remote control (specific types only)
1 Place the batteries in the battery compartment (fig. 17).
Make sure the - and + poles are pointing in the right direction.
2 With the infrared remote control you can set the suction power to one of 5 different suction
power settings.When you switch the appliance on,it will always start running at the highest
suction power setting.
3 By pushing the - button,you will reduce the suction power by one setting (fig.18).
4 By pushing the + button,you will increase the suction power by one setting.
5 Push the standby button to temporarily switch the vacuum cleaner off,for instance when you
have to move some furniture.
6 To continue vacuum cleaning,simply press the - button or the + button.The appliance will
start operating at the previously selected suction power setting again.
Storage
1 Switch the appliance off.
2 Remove the mains plug from the wall socket.
3 Rewind the mains cord by pressing the cord rewind button (fig.19).
4 Put the appliance in upright position and attach the lower tube to the appliance by means of
the clip (fig.20).
◗The height of the clip can be adjusted by sliding it along the tube.
Replacing the dustbag
◗Replace the dustbag as soon as the "dustbag-full indicator" changes colour (when the nozzle
is not placed on the floor).
1 Switch the appliance off.
2 Open the cover (fig.21).
3 Push the dustbag holder backwards (fig.22).
Page 9
4 Remove the full dustbag from the holder by pulling the cardboard tag (fig.23).
When you do this,the dustbag will be automatically sealed.
5 Slide the cardboard front of the new dustbag into the two grooves of the dustbag holder.
Press it down as far as possible (fig.24).
6 Pull the dustbag holder forwards (you will hear a click) (fig.25).
You cannot close the cover if no dustbag has been inserted.
Replacing filters
Motor Protection Filter
1 Replace the Motor Protection Filter when you insert the first of a new set of dustbags or
once a year.
2 Insert the filter into the appliance with the white side facing upwards (fig.26).
AFS Micro Filter
The AFS Micro Filter in this appliance will remove a large part of the smallest particles from the
exhaust air by means of its electrostatically charged fibres.
1 Replace the AFS Micro Filter when you insert the first of a new set of dustbags or once a
year (fig.27).
2 Place the sides and the bottom edge of the new filter properly behind the ridges of the
holder (fig.28).
3 Make sure the filter has been properly inserted into the holder before you close the filter
holder.
HEPA Filter (specific types only)
Some appliances are equipped with a HEPA Filter.This filter not only removes household dust,but
also harmful microscopic vermin.
1 Replace the HEPA Filter at least once a year.
9ENGLISH
2 Open the filter grill (fig.29).
3 Push both catches sidewards and remove the filter (fig.30).
4 Place the new filter with its white side pointing towards the appliance.Make sure that the
Philips logo on the filter is visible and in the upper right-hand corner (fig.31).
5 Secure the filter by pushing the catches home and close the filter grill (fig.32).
Ordering dustbags and filters
Philips s-bag` paper dustbags are available under type number FC8021.
The recommended dustbags fit a variety of Philips vacuum cleaners. For compact vacuum cleaners
like the City Line or the Impact,this means that the dustbags will not be filled to their maximum
capacity,as the capacity of the dust compartment is smaller than that of the dustbag. However, this
does not prevent your vacuum cleaner from functioning optimally.
Two AFS Micro Filters and one Motor Protection Filter are available under type number FC8032 .
HEPA Filters are available under type number HR6992.
Page 10
10ENGLISH
If you have any difficulties obtaining dustbags,filters or other accessories for this appliance,please
contact the Philips Customer Care Centre.
See the worldwide guarantee leaflet for telephone numbers of the Philips Customer Care Centre.
Environment
To make recycling possible, the plastics used for this appliance have been coded.
The cardboard packaging has been made of recycled material and is fully recyclable.
Remove the batteries when you discard the appliance.Do not throw the batteries away with the
normal household waste, but hand them in at an official collection point.You can also take the
batteries to a Philips service centre,which will dispose of them in an environmentally safe way.
Replacing the mains cord
If the mains cord of this appliance is damaged,it must always be replaced by Philips or a service
centre authorised by Philips,as special tools and/or parts are required.
Solving problems
◗The suction power is insufficient:
1 Adjust the suction power by pushing the + button of the remote control (specific types only)
(fig.33).
2 Set the electronic suction power control to a higher setting (specific types only) (fig.34).
3 Check if the dustbag needs to be replaced.
4 Check if the filters need to be replaced.
5 Check if the nozzle, tube or hose is blocked up.
6 To remove the obstruction,disconnect the blocked-up item and connect it (as far as possible)
in reverse position.Switch the vacuum cleaner on to make the airflow suck the obstructing
material out of the blocked-up item (fig.35).
◗The infrared remote control does not function (FC 8412):
7 It is possible that the batteries are not making proper contact.
8 Remove the lid of the battery compartment and push the batteries back into place (fig. 17).
9 The batteries are empty.
10 Replace the batteries (make sure the - and the + poles of the new batteries are pointing in
the right direction).Use LR03 batteries, preferably alkaline batteries (fig.36).
Information & service
If you need information or if you have a problem,please visit the Philips Web site at
www.philips.com or contact the Philips Customer Care Centre in your country (you will find its
phone number in the worldwide guarantee leaflet). If there is no Customer Care Centre in your
country,turn to your local Philips dealer or contact the Service Department of Philips Domestic
Appliances and Personal Care BV.
Page 11
◗™
◗
◗
◗
◗
11
Page 12
12
◗
◗
◗
◗
◗
◗
1
1
2
3
4
1
2
3
4
1
2
3
Page 13
13
1
1
2
3
4
5
6
1
2
3
4
◗
◗
1
2
3
4
5
6
1
2
Page 14
14
1
2
3
1
2
3
4
5
™
Page 15
◗
◗
15
1
2
3
4
5
6
7
8
9
10
Page 16
16
09/2002
Page 17
17
Page 18
18
21
25
29
22
26
30
23
27
31
24
28
32
33
34
35
36
Page 19
19
Page 20
u
www.philips.com
4222 000 48444
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.