Philips FC8394 Service Manual

Vacuum cleaner
FC8394
Philips Domestic Appliances and Personal Care
Service Manual
PRODUCT INFORMATION
- Colour version /01/A : Fuchsia
- Built-in cord winder
- Dustbag-full indicator in dust cover
- This product meets the requirements regarding interference suppression on radio and TV.
- After the product has been repaired, it should function properly and has to meet the safety requirements as officially laid down at this moment.
TECHNICAL INFORMATION
- Maximum air displacement : 32 l/sec.
- Maximum vacuum water column : 350 cm
- Power consumption (IEC) 225V : 1400 W
- Dust storage capacity : 2 litres
- Cord length (depends on version) : 6.3 m
- Filter system : 5 filters
- Dimensions cleaner : 37 x 28 x 23 cm
- Net weight : 4.8 kg
- Noise : 80 dB max.
OPTIONAL (accessories)
DISASSEMBLY- AND RE-ASSEMBLY ADVISE
- Push the button panel (item 1) sideways to release it from the locking peg of the upper housing (item 3).
- When the button panel has been removed, you have access to the screws that need to be undone to disassemble the housing.
CC
C
B
AA
C
- Lift the motor housing (item 26) out of the lower housing and take out the cord winder unit.
- To disassemble the cord winder, use TORX screwdriver no. T10, which is one of a set consisting of T20; T15; T10; T9; T8; T7 and T6 (code number 4822 395 50145).
- FC8032 Exhaust air filter 4822 015 70056
- HR6997 S-Cotton dustbag 8836 997 01010
- FC8021 S-Paper dustbag 4822 480 10113
- FC8022 S-Clinic dustbag 8838 022 01010
- FC8023 S-Anti odor dustbag 8838 023 01000
Published by Philips Domestic Appliances and Personal Care Printed in the Netherlands © Copyright reserved Subject to modification
04/04
REPAIR INSTRUCTION
- The spare parts have been standardized as much as possible.
- Cotton dustbags are used in countries where paper dustbags are unobtainable.
- If the reel half spring unit is replaced, shaft F must be lubricated with silicone grease. Do not apply any silicone grease to or spill any grease on terminals (item 35) or conductors (item 34).
- Item 33 is provided with a long cord-winder spring, but both long and short cords can be used in combination with this spring. (L = 9.3 m)
- Depending on the length of the original cord, the spare cord may have to be shortened.
- The cord winder spring must be tensioned to the maximum level and then be rewound approx. 1.5 turn.
- The RPM can be adjusted by means of the potentiometer mounted on the PCB (item 23). The RPM is correctly adjusted if the motor starts automatically and continues to run smoothly with the ON/OFF position and the adjustable potentiometer in minimum position.
- If the function of the electronic control unit (item 23) is not required, the Triac must be short-circuited in the manner shown in the circuit diagram.
- When the vacuum cleaner is used to suck up fine dust, the pores of the dustbag may become clogged, causing the passage of air through the dustbag to become obstructed. As a result, the dustbag-full indicator will indicate that the dustbag needs to be replaced, even though the dustbag is not full at all.
FC8394
ELECTRICAL DIAGRAM
SPEED
CONTROL UNIT
M
C
Triac
CORD WINDER
Short-circuit
2-6