Philips ED-37 User Manual

CDM 350/C/V/O/PS/4K/ALTO
Lumen Maintenance
BURNING HOURS
RATED AVERAGE LIFE 24,000 HOURS
80%
100%
60% 40% 20%
0%
0 5000 10,000 15,000 20,000 24,000
% LUMEN
MAINTENANCE
P
atented coil design offers protection for open fixture rating
Patented dual frame o
ffers improved life
a
nd reliability
MasterColor®Pulse Start Ceramic Metal Halide 350 Watt ED-37 (Clear) Lamp
featuring ALTO®Lamp Technology
Q Ordering Information
Ordering Code CDM350/V/O/PS/4K/ALTO ANSI Designation M171/O, M131/O Product Number 132571 Description MasterColor Pulse Start
Ceramic Metal Halide
Package Quantity 6
Q Physical Characteristics
Mogul Screw (EX39) Max. Overall Length (MOL) 11.5 (292mm) Light Center Length (LCL) 7.0 (178mm) Arc Length 24mm Arc Tube Material Polycrystalline Alumina Max. Permissible Bulb Temp. 400°C (752°F) Max. Permissible Base Temp. 210°C (410°F) Maximum Bulb to Base Eccentricity 3º Maximum Arc Tube to Base Eccentricity 3º
Q Operating Characteristics (Photometric)
Rated Initial Lumens Mean Lumens,Approx. Rated Average Life, Hours 24,000 Correlated Color Temp. (CCT) CIE Chromaticity Approx. Color Rendering Index (CRI) 90 Efficacy (lpw) 90
1
2
2
2
31,500
25,200
4200K
x-.371, y-.372
Q Operating Position
Vertical ± 15°-Open or Enclosed Luminiares
Philips Lighting Company 200 Franklin Square Drive P.O. Box 6800 Somerset, NJ 08875-6800 1-800-555-0050
Division of Philips Electronics North America Corporation
A
pdated 5/07 TDS-132571
U
www.philips.com
Philips Lighting 281 Hillmount Road Markham, Ontario Canada L6C 2S3 1-800-555-0050
Division of Philips Electronics Ltd.
A
MasterColor®Pulse Start Ceramic Metal Halide 350 Watt ED-37 (Clear) Lamp featuringALTO
Electrical Data (
Lamp Watts (Nominal) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 350
Lamp Operating Voltage (rms) (Nominal)2. . . . . . . . . . . . 150
Initial Lamp Voltage Range (rms)3. . . . . . . . . . . . . . . . . . . . 135-165
Lamp Operating Current (Amps) (rms) (Nominal) . . . . . 2.83
Lamp Current Crest Factor (Maximum) . . . . . . . . . . . . . . 1.6
Warm-up Time to 80% of Output . . . . . . . . . . . . . . . . . . . 5 Minutes
Restrike Time for Hot Lamp. . . . . . . . . . . . . . . . . . . . . . . . . 15 Minutes
Ballast Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ANSI M171/M131/O
Ballast Open Circuit Voltage (Minimum). . . . . . . . . . . . . . . 254 RMS Min.
Pulse Peak Volts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3000 Minimum, 4000 Maximum
Pulse Width @ 90% Peak (2700 Volts) . . . . . . . . . . . . . . . . 1.3 Micro Second Minimum
Pulse Repetition Rate (Minimum) . . . . . . . . . . . . . . . . . . . . 1 per Half Cycle
Minimum Operating Temperature . . . . . . . . . . . . . . . . . . . . -30º C (-22°F)
1) Measured at 100 hrs of life in ver tical position.
2) Measured at rated lamp watts on a linear reactor. LPW does not include ballast losses.
3) Measured with the lamp operating at rated watts.
WARNINGS, CAUTIONS AND OPERATING INSTRUCTIONS for Protected MasterColor®Pulse Start Ceramic Metal Halide Lamps (Vertical Operation ± 15°, Open or Enclosed Fixtures )
Warnings, Cautions and Operating Instructions
“WARNING:These lamps can cause serious
R
skin burn and eye inflammation from short wave ultraviolet radiation if outer envelope of the lamp is broken or punctured. Do not use where people will remain for more than a few minutes unless adequate shielding or other safety precautions are used. Certain lamps that will automatically extinguish when the outer envelope is broken or punctured are commercially available.” This lamp complies with FDA radiation performance standard 21 CFR subchapter J. (USA:21CFR 1040.30 Canada:SOR/DORS/80-381)
If the outer bulb is broken or punctured, turn off at once and replace the lamp to avoid possible injury from hazardous short wave ultraviolet radiation.Do not scratch the outer bulb or subject it to pressure as this could cause the outer bulb to crack or shatter.A partial vacuum in the outer bulb may causeglass to fly if the envelope is struck.
WARNING:The arc-tube of metal halide lamps
are designed to operate under high pressure and at temperatures up to 1000º C and can unexpectedly rupture due to internal or external factors such as a ballast failure or misapplication. If the arc-tube ruptures for any reason, the outer bulb may break and pieces of extremely hot glass might be discharged into the surrounding environment. If such a rupture were to happen, THERE IS A RISK OF PERSONAL
INJURY, PROPERTY DAMAGE, BURNS AND FIRE.
Subject to change without notice)
These lamps are designed to retain all the glass particles should an arc tube rupture occur.The following operating instructions are recommended to minimize these occurrences.
RELAMP FIXTURES AT OR BEFORETHE END OF RATED LIFE.Allowing lamps to operate until they fail is not advised and may increase the possibility of inner arc tube rupture.
This lamp contains an arc tube with a filling gas containing Kr-85 and is distributed by Philips Lighting Company,a division of Philips Electronics North America Corporation, Somerset, New Jersey, 08875.
CAUTION: TO REDUCE THE RISK OF PERSONAL
INJURY, PROPERTY DAMAGE, BURNS AND FIRE RESULTING FROM AN ARC-TUBE RUPTURE THE FOLLOWING LAMP OPERATING
INSTRUCTIONS MUST BE FOLLOWED: LAMP OPERATING INSTRUCTIONS:
1. RELAMP FIXTURES AT OR BEFORE THE END OF RATED LIFE. Allowing lamps to operate until they fail is not advised and may increase the possibility of inner arc tube rupture.
2. Before lamp installation/replacement, shut power off and allow lamp and fixture to cool to avoid electrical shock and potential burn hazards.
3. Use only auxiliary equipment meeting Philips and/or ANSI standards. Use within voltage limits recommended by ballast manufacturer.
A. Operate lamp only within specified limits of operation.
B. For total supply load refer to ballast manufacturers
electrical data.
C. All Pulse Start mogul based lamps require a socket
rated to withstand a 4000 volt pulse.
4. Periodically inspect the outer envelope. Replace any lamps that show scratches, cracks or damage.
5. If a lamp bulb suppor t is used, be sure to insulate the support electrically to avoid possible decomposition of the bulb glass.
6. Protect lamp base, socket and wiring against moisture, corrosive atmospheres and excessive heat.
7. Time should be allowed for lamps to stabilize in color when turned on for the first time. This may require several hours of operation, with more than one start. Lamp color is also subject to change under conditions of excess vibration or shock, and color appearance may vary between individual lamps.
8. Lamps may require 10 to 20 minutes to re-light if there is a power interruption.
9. Take care in handling and disposing of lamps. If an arc tube is broken, avoid skin contact with any of the contents or fragments.
10. Use this lamp only in fixtures that contain Pulse Start
metal halide ballasts and are specifically use with Pulse Star t metal halide lamps.
®