Philips DYNALITE DMC4, DYNALITE DMC4-CE, DYNALITE DMC4-UL Installation Instructions Manual

DMC4
Dynalite Modular Controller (4 Output Modules) Installation Instructions
Warning…………………………………………….. 2 Final Checks……………………..……………….. 6 Features…………………………………………….. 2 Dimensions…………….……………………….….. 7
Important Safeguards…………………………….. 2 Specications………………………………………. 8
Internal View……………………………………….. 3 Mounting…………………………………….……… 4 Module mounting…………………..……………… 5
DMC4 Installation Instructions Rev 02 Specications subject to change without notice
E-Mail: support.controls@philips.com Web: http://philips.com/dynalite
2
DMC4 Installation Instructions Rev 02
Features
Four Control Module Locations
Wide range of interchangeable control modules available to meet the capacity and control type needs of any project.
Modules supplied separately.
The DMC4 is only compatible with Philips Dynalite modules.
Communication Module
Allows the controller to be used with a variety of
supported protocols.
Convection Cooled
The DMC4 is ventilated, and requires no active
cooling system when installed in accordance with these instructions.
Multiple Control Options
The DMC4 is designed to operate as part of a network system that can be structured to meet the project’s needs.
Simple Installation
The enclosure is suitable for both surface and recess mount. Cabling knockouts for supply and load cables are provided at the top, side and back of the enclosure for supply and load cables. Cabling knockouts for Control cables (Class 2 / SELV) are located at the bottom of enclosure.
Important Safeguards
Read the Instructions – We recommend that you read this instruction manual prior to commencement of installation. Do not energize the DMC4 until all steps of the installation procedure on page 6 are complete.
Compliance The temperature limits and carrying capacity of communication wires must comply with HD
384.5.523 and the installation of home and building
automation and control systems must comply with HD
60364-4-41.The network topology for installation is Daisy
Chain.
Special Programming – Once assembled, powered and terminated correctly, this device will operate in basic mode. A new Philips Dynalite user interface on the same
network will turn all output lighting channels on from
button 1 and off from button 4 allowing testing of network cables and terminations. Advanced functions and custom presets can then be congured via the EnvisionProject
commissioning software.
If commissioning services are required, contact your local distributor for details.
Power Sources – This device should only be operated from the type of supply specied on installed modules. This device must be earthed.
High Voltage Insulation Test – Do not apply High
Voltage Insulation Test to any circuitry connected to the dimming system, as damage to the electronics may result.
Mounting Location – This device must be mounted
upright on a vertical surface (refer to page 4 for mounting
instructions). The specied minimum clearance of 200mm (8”) for all sides must be adhered to. Install in a dry, well-ventilated location.
Audible Noise – Controllers may emit some audible noise such as humming or relay chatter. Take this into account
when deciding the mounting location.
Data Cable – The recommended cable for connections to the serial port is screened stranded RS485 compatible CAT-5E data cable with three twisted pairs. Refer to the
installation instructions for the communication module for
more cabling information. This cable must be segregated from mains and Class 1 cables as per local electrical code. If anticipated cable runs are over 300 m (1000 ft) for serial cables, consult your dealer for advice. Do not cut or terminate live data cables.
3
DMC4 Installation Instructions Rev 02
Internal View
Supply
module
install
location
Communication
bus and power
connection
Control
module 1
install
location
Communication
bus connection
Control
module 2
install
location
Communication
bus connection
Surface mounting
sleeve
Wall mounting point
Wall mounting point
Communication
bus cover
Knockouts for load
group channels
High voltage barrier
Data cable entry points
Surface mounting
sleeve
For spare parts, please call your nearest Philips Dynalite Customer Service Centre.
Comms module
install location
Communication
bus connection
Control
module 3
install
location
Communication
bus connection
Control
module 4
install
location
Communication
bus connection
Knockouts for load
group channels
Knockouts for supply
cables