Philips BY359-1500S, BY359-1500 Datasheet

Philips Semiconductors Product specification
Damper diode BY359-1500, BY359-1500S fast, high-voltage
FEATURES SYMBOL QUICK REFERENCE DATA
• Low forward volt drop VR = 1500 V
• Fast switching
• Soft recovery characteristic VF 1.8 V / 2 V
• High thermal cycling performance
• Low thermal resistance I
GENERAL DESCRIPTION PINNING SOD59 (TO220AC)
k a 12
F(RMS)
trr 600 ns / 350 ns
= 15.7 A
I
60 A
FSM
Glass-passivated double diffused PIN DESCRIPTION rectifierdiode featuring low forward
tab
voltage drop, fast reverse recovery 1 cathode and soft recovery characteristic. Thedeviceisintendedforuse in TV 2 anode receivers and PC monitors.
tab cathode The BY359 series is supplied in the conventional leaded SOD59
1
(TO220AC) package.
2
LIMITING VALUES
Limiting values in accordance with the Absolute Maximum System (IEC 134).
SYMBOL PARAMETER CONDITIONS MIN. MAX. UNIT
V
RSM
V
RRM
V
RWM
I
F(peak)
I
F(RMS)
I
FRM
I
FSM
T
stg
T
j
Peak non-repetitive reverse - 1500 V voltage Peak repetitive reverse voltage - 1500 V Crest working reverse voltage - 1300 V Peak forward current 16-32kHz TV BY359-1500 - 10 A
31-70kHz monitor BY359-1500S - 7 A RMS forward current - 15.7 A Peak repetitive forward current sinusoidal; a = 1.57 - 60 A Peak non-repetitive forward t = 10 ms - 60 A current t = 8.3 ms - 66 A
sinusoidal; Tj = 150 ˚C prior to surge;
with reapplied V
RWM(max)
Storage temperature -40 150 ˚C Operating junction temperature - 150 ˚C
THERMAL RESISTANCES
SYMBOL PARAMETER CONDITIONS MIN. TYP. MAX. UNIT
R
th j-mb
R
th j-a
September 1998 1 Rev 1.300
Thermal resistance junction to - - 2.0 K/W mounting base Thermal resistance junction to in free air. - 60 - K/W ambient
Philips Semiconductors Product specification
Damper diode BY359-1500, BY359-1500S fast, high-voltage
STATIC CHARACTERISTICS
Tj = 25 ˚C unless otherwise stated
BY359-1500 BY359-1500S
SYMBOL PARAMETER CONDITIONS TYP. MAX. TYP. MAX. UNIT
V
F
I
R
DYNAMIC CHARACTERISTICS
Tj = 25 ˚C unless otherwise stated
SYMBOL PARAMETER CONDITIONS TYP. MAX. TYP. MAX. UNIT
t
rr
Q
s
Forward voltage IF = 20 A 1.3 1.8 1.5 2.0 V
IF = 10 A; Tj = 150˚C 1.00 1.5 1.25 1.75 V
Reverse current VR = 1300 V 10 100 10 100 µA
VR = 1300 V; 50 300 100 600 µA Tj = 100 ˚C
BY359-1500 BY359-1500S
Reverse recovery time IF = 2 A; VR 30 V; 0.47 0.60 0.28 0.35 µs Reverse recovery charge -dIF/dt = 20 A/µs 1.6 2.0 0.70 0.95 µC
V
fr
Peak forward recovery voltage IF = 10 A; 11.0 - 17.0 - V
dIF/dt = 30 A/µs
I
F
time
V
F
V
fr
V
F
time
Fig.2. Definition of V
fr
I
rrm
dI
F
dt
trr
time
Qs
25%
rrm
100%
I
F
I
R
Fig.1. Definition of trr, Qs and I
September 1998 2 Rev 1.300
Loading...