Philips BL25 Series Installation Instructions Manual

Page 1
INSTALLATION INSTRUCTIONS
BL25 BOLLARD SERIES
200 Franklin Square Drive, Markham ON, Canada L6C 2S3 Somerset, NJ 08873, USA
READ, UNDERSTAND, and FOLLOW
ELECTRICAL SHOCK HAZARD
WARNING
Disconnect the electrical supply power at the service panel (fuse or circuit breaker box). Failure to do so could result in serious injury or death. Only qualified electricians should install this fixture and the installation MUST conform with the National Electrical Code and all applicable local codes and ordinances. Ensure that only proper tools, materials, and equipment are used during installation.
SAFETY
Proper grounding is required to ensure personal safety. Do not use this equipment for anything other than its intended purpose. Servicing this equipment should be performed by qualified service personnel. Installer must assure installation including integrity of anchor bolts,foundation
and tightening of anchor nuts.
Make sure all four set screws supplied to attach bollard to the base plate are installed and completely tight.
Installer must assure that all gaskets provided to seal the optical section of the bollard are in place and not damaged during assembly. The gaskets keep out insects and keep moisture from entering and collecting on the lens.
Save these instructions
equipment.
6”[152.4mm]
, and
ø8" [ø203.2 mm]
42’’[1066.8mm]
(3) Sets of Locking Washers & Nuts
Base plate
(3) Anchor J-Bolts
3”[76.2mm]
ANCHOR BOLT INSTALLATION
CAUTION: Install according to all applicable local codes.
Install three (3) Anchor J-Bolts in concrete foundation (by others) using the template provided. Bollard Base may also be used as the template. Bolt threads should protrude at least 3” from concrete.
BOLLARD INSTALLATION
To allow for base plate leveling, before inserting base plate, place one nut followed by a washer onto each Anchor J-Bolt. Place Base Plate over anchor J-bolts and leveling nuts. Loosely tighten flat washers and nuts onto J-bolts. Level base plate by adjusting the leveling nuts under the base plate.Then tighten the upper nuts on top of the base plate. Secure wires above g round level.
Make appropriate wiring connections as per instructions below. Place fixture over the base plate.
Secure bollard onto the base plate by progressively tightening the four set screws at the bottom of the column.
If required, retighten the four set screws that assembles the bollard head to shaft and secure appropriately.
Base Plate
(4)
Set Screws
Wiring Conduit (By Others)
(3) Sets of Leveling Washers & Nuts
Concrete Foundation
Wiring Conduit
(By Others)
(3) Sets of Locking Washers & Nuts
(3) Sets of Leveling Washers
Concrete Foundation
(3) Anchor J-Bolts
1FIXTURE IS SUITABLE FOR WET LOCATIONS
Page 2
INSTALLATION INSTRUCTIONS
BL25 BOLLARD SERIES
ELECTRICAL WIRING
Make wiring connections (as stated below) and secure above the ground. Check that the line voltage is correct.
Connect fixture GROUND (green) wire to power supply GROUND (green) wire. Connect fixture WHITE wire to power supply (-) NEUTRAL COMMON wire. Connect fixture BLACK wire to power supply (+) HOT LINE wire
CLEANING & MAINTENANCE
CAUTION: Ensure fixture temperature is cool enough to touch. Do not clean or maintain while fixture is powered.
Clean lens with non-abrasive cleaning solution. Do NOT open fixture to clean the LEDs.
200 Franklin Square Drive, Markham ON, Canada L6C 2S3 Somerset, NJ 08873, USA
TROUBLESHOOTING
If fixture does not turn on, check that the line voltage at fixture is correct. Check wiring diagram. Ensure fixture is grounded. If fixture is flickering, ensure fixture is compatible with the input power and is not wired to a dimming switch. If fixture is not level, use the leveling nuts under the base plate to adjust bollard level.
ANCHOR BOLT TEMPLATE FOR BL25 BOLLARD
Drawing not to scale. Use provided template or actual base plate as your template.
120
120
ø0.374" [ø9.5 mm]
ø5.748’’ [ø146mm]
ø6.693’’ [ø170mm]
ø3’’[ ø76.2mm]
FIXTURE IS SUITABLE FOR WET LOCATIONS
2