Philio Technology PSM02 User Manual

Slim Multi-Sensor PSM02
The slim multi-sensor PSM02 has PIR, door/window, temperature and illumination, 4 sensors function in one, based on Z-WaveTM technology. Z-WaveTM is a wireless communication protocol designed for home automation, specifically to remotely control applications in residential and light commercial environments. The technology uses a low-power RF radio embedded or retrofitted into home electronics devices and systems, such as lighting, home access control, entertainment systems and household appliances.
This device is one component of the Z-WaveTM sensor system and is designed to work with all other Z-WaveTM enabled devices in a home control network. The device adopt the Z-WaveTM 400 series chip, when your Z-WaveTM network system is all made by Z-WaveTM 400 series devices. The network system will have the advantages as below.
Concurrent multi-channel support reduces external interference.
Better RF range, improve about 10 meters in indoor.
Support 100 Kbps transmit speed, speed up communication.
Adding to Z-WaveTM Network
There are two tamper keys in the device, one is in the back side, another is in the front side. They have the same function. Both of them can inclusion, exclusion, reset or association from Z-WaveTM network.
In the first time, add the device into the Z-WaveTM network. First, make sure the primary controller is in the inclusion mode. And then power on the device, just take out the insulation Mylar in the back side of the device. The device will auto start the NWI (Network Wide Inclusion) mode. And it should be included in 5 seconds. You will see the LED light ON one second.
Function
Description
Inclusion
1. Have Z-WaveTM Controller entered inclusion mode.
2. Pressing tamper key three times within 1.5 seconds will enter inclusion mode.
3. After inclusion successful, the device will wake to receive the setting command from Z-WaveTM Controller about 20 seconds.
Exclusion
1. Have Z-WaveTM Controller entered exclusion mode.
2. Pressing tamper key three times within 1.5 seconds will enter exclusion mode. Node ID has been excluded.
Reset
1. Pressing tamper key four times within 1.5 seconds and do not release the tamper key in the 4th pressed, and the LED will turn ON.
2. After 3 seconds the LED will turn OFF, after that within 2 seconds, release the tamper key. If successful, the LED will light ON one second. Otherwise, the LED will flash once.
3. IDs are excluded and all settings will reset to factory default.
1
Association
1. Have Z-WaveTM Controller entered association mode.
2. Pressing tamper key three times within 1.5 seconds will enter association mode.
Note: The device support 2 groups. The group 1 is for receiving the report message, like triggered event, temperature, illumination etc. The group 2 is for light control, the device will send the “Basic Set” command to this group.
Including a node ID allocated by Z-WaveTM Controller means inclusion. Excluding a node ID allocated by Z-WaveTM Controller means exclusion.
Failed or success in including/excluding the node ID can be viewed from Z-WaveTM Controller.
Notice 1: Always RESET a Z-WaveTM device before trying to add it to a Z-WaveTM network.
Notice 2: When the device into NWI mode, any tamper key and sensor functionality will useless. The NWI will timeout after 30 seconds.
Z-WaveTM Notification
After the device adding to the network, it will wake-up once per day in default. When it wake-up it will broadcast the “Wake Up Notification” message to the network, and wake-up 10 seconds for receive the setting commands. The wake-up interval minimum setting is 30 minutes, and maximum setting is 120 hours. And the interval step is 30 minutes.
If the user want to wake-up the device immediately, please remove the front cover, and press the tamper key once. The device will wake-up 10 seconds.
Z-WaveTM Message Report
* Motion Report:
When the PIR motion detected, the device will unsolicited to send the “Sensor Binary Report” to the nodes in the group 1. Sensor Type: Motion (0x0C) Sensor Value: 0xFF
* Door/Window Report:
When the Door/Window state changed, the device will unsolicited to send the “Sensor Binary Report” to the nodes in the group 1. Sensor Type: Door/Window (0x0A) Sensor Value: 0x00 is closed, 0xFF is opened.
* Tamper Report:
When the 2 tamper keys in the device are pressed over 5 seconds. The device will into the alarm state. In that state, if any one of the tamper keys be released, the device will unsolicited to send the “Sensor Binary Report” to the nodes in the group 1. Sensor Type: Tamper (0x08) Sensor Value: 0xFF
* Temperature Report:
When the PIR motion detected or the door/window state changed, the device will unsolicited to send the “Sensor Multilevel Report” to the nodes in the group 1. Sensor Type: Temperature (0x01) Note: To disable this functionality by setting the configuration setting N0.5, the bit5 of the value to 1.
*** Temperature differential report *** This function default is disabled, to enable by setting the configuration setting NO.6 bit6 to 1. When the temperature plus or minus three degree Fahrenheit (1.67 degree Celsius), the device will report temperature information to the
2
nodes in the group 1. The device will measure the temperature in every 64 seconds. And if the temperature is over 140 degree Fahrenheit (60 degree Celsius), the device also report in each measurement.
* Illumination Report:
When the PIR motion detected or the door/window state changed, the device will unsolicited to send the “Sensor Multilevel Report” to the nodes in the group 1. Sensor Type: Luminance (0x03) Note: To disable this functionality by setting the configuration setting N0.5, the bit4 of the value to 1.
* Timing Report:
Beside the event triggered could report message, the device also support the timing unsolicited report of the status.
Battery level report: Every 6 hours report once in default. It could be changed by configuration setting NO. 10.
Low battery report: When the battery level is too low, every 30 minutes will report once.
Door/window state report: Every 6 hours report once in default. It could be changed by configuration setting NO. 11.
Illumination level report: Every 6 hours report once in default. It could be changed by configuration setting NO. 12.
Temperature report: Every 6 hours report once in default. It could be changed by configuration setting NO. 13.
Power Up Procedure
* Battery Power Check
When the power up, the device will detect the power level of the battery immediately. If the power level is too low, the LED will continue flash about 5 seconds. Please change another new battery.
* PIR Warm Up
When the power on, the PIR need to warm up before operation. The warm up time about 1 minute, the LED will flash in every 2 seconds. After finish the procedure the LED will light ON three times.
* NWI
When the power on, the device will check is it already adding to the network? If doesn't, it will auto start the NWI mode. The LED will flash in every second and continue 30 seconds. Until timeout or the device successful to inclusion by controller.
* Wake
When the power on, the device will wake about 20 seconds. In this duration, the controller can communicate with the device. Normally the device is always sleeping to save the battery energy.
Function DIP Switch
There is one function DIP switch in front of the device. Remove the front cover in the right top of the PCB, and also has mark “M1” and “M2” for two switch.
M1 M2 Description ON ON Test Mode. ON OFF Security Mode.
OFF ON Home Automation Mode.
OFF OFF
Program Mode. According to the configuration setting NO. 5 to set the operation mode.
Operation Mode
There are three operation modes of the device. The user can choosing the suitable mode for application.
3
Loading...
+ 7 hidden pages