Philio Technology PSE02 User Manual

Multi Sound Siren PSE02
The multi sound siren PSE02 is a wireless siren, based on Z-Wave
TM
technology. Z-WaveTM is a wireless communication protocol designed for home automation, specifically to remotely control applications in residential and light commercial environments. The technology uses a low-power RF radio embedded or retrofitted into home electronics devices and systems, such as lighting, home access control, entertainment systems and household appliances.
This device is one component of the Z-WaveTM system and is designed to work with all other Z-WaveTM enabled devices in a home control network. The device adopt the Z-WaveTM 400 series chip, when your Z­WaveTM network system is all made by Z-WaveTM 400 series devices. The network system will have the advantages as below.
Concurrent multi-channel support reduces external interference.
Better RF range, improve about 10 meters in indoor.
Support 100 Kbps transmit speed, speed up communication.
Product Overview
Adding to Z-WaveTM Network
There are one tamper key behind the device. It could inclusion, exclusion, reset or association from Z-WaveTM network.
In the first time, add the device into the Z-WaveTM network. First, make sure the primary controller is in the inclusion mode. And then power on the device. The device will auto start the NWI (Network Wide Inclusion) mode. And it should be included in 5 seconds. You will see the LED light ON one second.
Function
Description
Inclusion
1. Have Z-WaveTM Controller entered inclusion mode.
2. Pressing tamper key three times within 1.5 seconds will enter inclusion mode.
3. After inclusion successful, the device will wake to receive the setting command from Z-WaveTM Controller about 20 seconds.
1
Siren
Tamper Key
Circle Button
Battery
(Optional)
DC Jack
Exclusion
1. Have Z-WaveTM Controller entered exclusion mode.
2. Pressing tamper key three times within 1.5 seconds will enter exclusion mode. Node ID has been excluded.
Reset
1. Pressing tamper key four times within 1.5 seconds and do not release the tamper key in the 4th pressed, and the LED will turn ON.
2. After 3 seconds the LED will turn OFF, after that within 2 seconds, release the tamper key. If successful, the LED will light ON one second. Otherwise, the LED will flash once.
3. IDs are excluded and all settings will reset to factory default.
Association
1. Have Z-WaveTM Controller entered association mode.
2. Pressing tamper key three times within 1.5 seconds will enter association mode.
Note: The device support 6 groups. The group 1 is for receiving the report message, like tamper event. The group 2 to 6 will map to different sound, when the device got the BASIC Set 0xFF, it will check is the node in which group, and play the mapping sound. The group 2 mapping to emergency alarm. The group 3 mapping to fire alert. The group 4 mapping to ambulance sound. The group 5 mapping to police car sound. The group 6 mapping to door chime.
Including a node ID allocated by Z-WaveTM Controller means inclusion. Excluding a node ID allocated by Z-WaveTM Controller means exclusion.
Failed or success in including/excluding the node ID can be viewed from Z-WaveTM Controller.
Notice 1: Always RESET a Z-WaveTM device before trying to add it to a Z-WaveTM network.
Notice 2: When the device into NWI mode, any tamper key and sensor functionality will useless. The NWI will timeout after 3 minutes.
Z-WaveTM Message Report
* Tamper Report:
When the tamper key is pressed over 5 seconds. The device will into the alarm state. In that state, if the tamper key be released, the device will unsolicited to send the “Sensor Binary Report” to the nodes in the group 1. Sensor Type: Tamper (0x08) Sensor Value: 0xFF
* Siren Alarm State Report:
When the siren start playing or stop the alarm sounds, the device will unsolicited to send the “Sensor Binary Report” to the nodes in the group 1. Sensor Type: General Purpose (0x01) Sensor Value: 0xFF (Start play), or 0x00 (Stop play)
Power Up Procedure
When the power on, the device will check is it already adding to the network? If doesn't, it will auto start the NWI mode. The LED will flash in every second and continue 3 minutes. Until timeout or the device successful to inclusion by controller.
2