Exclusion
1. Have Z-WaveTM Controller entered exclusion mode.
2. Pressing tamper key three times within 1.5 seconds
will enter exclusion mode.
Node ID has been excluded.
Reset
1. Pressing tamper key four times within 1.5 seconds
and do not release the tamper key in the 4th
pressed, and the LED will turn ON.
2. After 3 seconds the LED will turn OFF, after that
within 2 seconds, release the tamper key. If
successful, the LED will light ON one second.
Otherwise, the LED will flash once.
3. IDs are excluded and all settings will reset to
factory default.
Association
1. Have Z-WaveTM Controller entered association
mode.
2. Pressing tamper key three times within 1.5 seconds
will enter association mode.
Note: The device support 6 groups.
The group 1 is for receiving the report message, like
tamper event.
The group 2 to 6 will map to different sound, when the
device got the BASIC Set 0xFF, it will check is the node
in which group, and play the mapping sound.
The group 2 mapping to emergency alarm.
The group 3 mapping to fire alert.
The group 4 mapping to ambulance sound.
The group 5 mapping to police car sound.
The group 6 mapping to door chime.
• Including a node ID allocated by Z-WaveTM Controller means
inclusion. Excluding a node ID allocated by Z-WaveTM
Controller means exclusion.
• Failed or success in including/excluding the node ID can be
viewed from Z-WaveTM Controller.
Notice 1: Always RESET a Z-WaveTM device before trying to add it to a
Z-WaveTM network.
Notice 2: When the device into NWI mode, any tamper key and
sensor functionality will useless. The NWI will timeout after 3 minutes.
Z-WaveTM Message Report
* Tamper Report:
When the tamper key is pressed over 5 seconds. The device will into
the alarm state. In that state, if the tamper key be released, the device
will unsolicited to send the “Sensor Binary Report” to the nodes in the
group 1.
Sensor Type: Tamper (0x08)
Sensor Value: 0xFF
* Siren Alarm State Report:
When the siren start playing or stop the alarm sounds, the device will
unsolicited to send the “Sensor Binary Report” to the nodes in the
group 1.
Sensor Type: General Purpose (0x01)
Sensor Value: 0xFF (Start play), or 0x00 (Stop play)
Power Up Procedure
When the power on, the device will check is it already adding to the
network? If doesn't, it will auto start the NWI mode. The LED will flash
in every second and continue 3 minutes. Until timeout or the device
successful to inclusion by controller.