Philio Technology PAT05 Users manual

Air Quality Multi Sensor PAT05
T
he PAT05 multi-sensor is a device that allows you to check the air quality in your home, as well as detect temperature and humidity. The PAT05 Multi-sensor is easy to use and very convenient for your home. Just set the sensor on the wall of the rooms you would like to control, and you are ready to go. Moreover, the PAT05 can be integrated to other Z-Wave certified devices, and controlled with Philio app “Home Mate 2.” You can now protect your family and make sure there are no gas leaks or moisture that can harm those you love the most. Set up your PAT05 to send regular notifications and take control even when not at home.
This device is a security enabled Z-Wave Plus product that is able to use encrypted Z­Wave Plus messages to communicate to other security enabled Z-Wave Plus products. Z-WaveTM enabled devices displaying the Z-WaveTM logo can also be used with it regardless of the manufacturer, and ours can also be used in other manufacturer’s Z-WaveTM enabled networks.
The product supports Over The Air(OTA) feature for the products firmware upgrade.
This product can be included and operated in any Z-WaveTM network with other Z­WaveTM certified devices from other manufacturers and/or other applications. All non­battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network.
The device adopt the Z-WaveTM 500 series chip, when your Z-WaveTM network system is all made by Z-WaveTM 500 series devices. The network system will have the advantages as below.
Notice:
Once you have completed the setup process, Please allow for a 7-Day settling period for the sensors to adjust to their new environment and to observe a typical cycle of air quality, based on your activity within a 1 week period.
Add to/Remove from Z-WaveTM Network
There are two tamper keys in the device, one is in the back side, another is in the front side. Both of them can add, remove, reset or association from Z-Wave network.
The table below lists an operation summary of basic Z-Wave functions. Please refer to the instructions for your Z-WaveTM Certificated Primary Controller to access the Setup function, and to Add/Remove/associate devices
Notice: Including a node ID allocated by Z-WaveTM Controller means “Add” or Inclusion”. Excluding a node ID allocated by Z-WaveTM Controller means “Remove” or “Exclusion”.
Function
Add (Inclusion)
Description
1.
Have Z-WaveTM Controller entered inclusion mode.
1
TM
2. Pressing tamper key three times within 2 seconds to enter the inclusion mode.
3.
After add successful, the device will wake to receive the setting command from Z-WaveTM Controller about 20 seconds.
1.
Have Z-WaveTM Controller entered exclusion mode.
Remove (Exclusion)
Reset
SmartStart
Association
Adding a node ID allocated by Z-Wave Controller means inclusion. Removing a
2. Pressing tamper key three times within 2 seconds to enter the exclusion mode. Node ID has been excluded.
1. Pressing Include button of PAT05 three times within 2 seconds will enter inclusion mode.
2. Within 1 second, press Include button of PAT05 again for 5 seconds.
1. Product has a DSK string, you can key in first five digit to increment smart start process, or you can scan QR code.
2. SmartStart enabled products can be added into a Z-Wave network by scanning the Z-Wave QR Code present on the product with a controller providing SmartStart inclusion. No further action is required and the SmartStart product will be added automatically within 10 minutes of being switched on in the network vicinity.
1. The PAT05 is an always listening Z-Wave device, so associations may be added or removed by a controller at any time. Or If your controller requires to have the PAT05 send a 'node information frame' or NIF for associations, then pressing the On/Off button three times within 2 seconds will cause the PAT05 to send its NIF.
node ID allocated by Z-Wave Controller means exclusion.
Failed or success in including/excluding the node ID can be viewed from the Z-
Wave Controller.
Z-WaveTM Message Report
* eCO2 Report:
When the eCO2 detected state changed, the device will unsolicited to send the “Sensor Multilevel Report” to the nodes in the group 1. Sensor Type: eCO2 (0x11) *** eCO2 Differential percent Report*** This function default is enabled, to disable this function by setting the configuration NO.17 to 0. In the default, when the eCO2 is changed to percentage, the device will report eCO2 information to the nodes in the group 1.
Caution 1: If the configuration No.3, No.4, No.5, No.6 and No.7 is setting to 0 this functionality is useless.
* TVOC Report: When the TVOC detected state changed, the device will unsolicited to send the “Sensor Multilevel Report” to the nodes in the group 1. Sensor Type: TVOC (0x27) *** TVOC Differential percent Report *** This function default is enabled, to disable this function by setting the configuration NO.18 to 0. In the default, when the TVOC is changed to percentage, the device will report TVOC information to the nodes in the group 1.
Caution 1: If the configuration No.8, No.9, No.10, No.11 and No.12 is setting to 0 or 100, this functionality is useless.
2
* Timing Report:
Beside the event triggered could report message, the device also support the timing unsolicited report of the status.
eCO2 report: Every 3 minute report once in default. It could be changed by setting the configuration NO. 14.
TVOC report: Every 6 hours report once in default. It could be changed by setting the configuration NO. 15.
Notice: The configuration NO. 14 and 15 could be setting to zero to disable the auto report. And the configuration NO. 16 could change the tick interval, the default value is 3, if setting to 1, that means the minimum auto report interval will be one minute.
Security Network
The device support the security function. When the device included with a security controller, the device will auto switch to the security mode. In the security mode, the follow commands need using Security CC wrapped to communicate, otherwise it will not response.
COMMAND_CLASS_VERSION_V3 COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 COMMAND_CLASS_DEVICE_RESET_LOCALLY COMMAND_CLASS_ASSOCIATION_V2 COMMAND_CLASS_ASSOCIATION_GRP_INFO COMMAND_CLASS_POWERLEVEL COMMAND_CLASS_CONFIGURATION COMMAND_CLASS_NOTIFICATION_V8 COMMAND_CLASS_FIRMWARE_UPDATE_MD_V4 COMMAND_CLASS_SENSOR_MULTILEVEL_V11
Z-Wave Configuration Settings
Notice:
* All of the configuration, the data size is 1. * The configuration mark with star(*), means after the remove the setting still keep, don't reset to factory default. Unless the user execute the “RESET” procedure. * The reserve bit or not supported bit is allowed any value, but no effect.
3
Loading...
+ 4 hidden pages