Philio Technology PAN08 Users manual

PAN08-1/-2/-3 Roller shutter controller
P
Fig 1. Assembling
The in-wall Roller Shutter Controller is designed to switch rise/lower roller shutter
connected to its terminals using radio waves, controllers and a push button directly
connected to this Roller Controller.
This in-wall Roller Shutter Controller is a transceiver which is a Z-WaveTM enabled
the Controller can easily hide itself into the wall box and that will be good for the
house decoration.
The new smart relay calibration technology can reduce the inrush current caused by
the load and let the module work perfectly with many kind of Roller Shutter.
This in-wall Roller Shutter Controller is able to detect position of the Shutter by using
the patterned power measuring method, so it can be remote controlled not only fully
up or down , but also can be adjusted to ex. 30% or 50%. And when manual
controlled by push button, the controller also can memorize the position and send the
new shutter position to its controller (ex. IP-Gateway).
Adding to Z-WaveTM Network
In the front casing, there is an include button with LED indicator below which is used
to carry out inclusion, exclusion, reset or association. When first power is applied, its
LED flashes on and off alternately and repeatedly at 2-second intervals. It implies
that it has not been assigned a node ID and cannot work with Z-Wave enabled
devices.
Auto Inclusion
The function of auto inclusion will be executed as long as the PAN08 does not have
Node ID and just connect the PAN08 to main power.
Note: Auto inclusion timeout is 4 minute during which the node information of
1
explorer frame will be emitted once every 5 seconds. Unlike “inclusion” function as
shown in the table below, the execution of auto inclusion is free from pressing the
Include button on the PAN08.
The table below lists an operation summary of basic Z-Wave functions. Please refer
to the instructions for your Z-WaveTM Certificated Primary Controller to access the
Setup function, and to include/exclude/associate devices
Function Description LED Indication
No node ID The Z-Wave Controller does not allocate
a node ID to the PAN08.
2-second on, 2-second off
Inclusion 1. Have Z-Wave Controller entered
inclusion mode.
One press one flash
2. Pressing Include button three times
within 1.5 seconds will enter
inclusion mode.
Exclusion 1. Have Z-Wave Controller entered
exclusion mode.
One press one flash
2. Pressing Include button three times
within 1.5 seconds will enter
exclusion mode.
Node ID has been excluded. 2-second on, 2-second off
Reset 1. Pressing Include button three times
within 1.5 seconds will enter
inclusion mode.
One press one flash
2. Within 1 second, press Include
button again for 5 seconds until LED
is off.
3. IDs are excluded. 2-second on, 2-second off
Association 1. Have Z-Wave Controller entered
association mode.
Or Pressing Include button three times
within 1.5 seconds will enter
association mode
One press one flash
2. There are 1 group (Group 1) for the
PAN08
Including a node ID allocated by Z-Wave Controller means inclusion. Excluding a node
ID allocated by Z-Wave Controller means exclusion.
Failed or success in including/excluding the node ID can be viewed from the Z-Wave
Controller.
LED Indication
To distinguish what mode the PAN08 is in, view from the LED for identification.
State Type LED Indication
Motor
activate
No matter up or down, close or open, Led will flash every second
while Motor activate.
No node ID Under normal operation, when the PAN08 has not been allocated
a node ID, the LED flashes on and off alternately at 2-second
intervals. By pressing S1 S2 or Include button, it will stop flashing
temporarily. However, after disconnect and reconnect the PAN08,
the LED will flash on and off alternately at 2-second intervals.
2
Overload When overload state occurs, the PAN08 is disabled of which LED
flashes on and off alternately at 0.5 second intervals. Overload
state can be cleared by disconnect and reconnect the PAN08 to
the main power
Choosing a Suitable Location
1. Do not locate the PAN08 facing direct sunlight, humid or dusty place.
2. The suitable ambient temperature for the PAN08 is 0°C~40°C.
3. Do not locate the PAN08 where exists combustible substances or any source of
heat, e.g. fires, radiators, boiler etc.
4. After putting it into use, the body of PAN08 will become a little bit hot of which
phenomenon is normal.
Installation and operation
1. put the in wall PAN08 into a wall box and connect the AC power wire L,N to
PAN08 connector L, N.
2. Connect the wall switch to the PAN08 as Fig1 .
3. It is important to carry out a shutter calibration process before you control the
shutter to move. Press inclusion button over 3 seconds and release before the
6th second, the roller shutter controller will start the shutter calibration process.
The process is composed of three continue stages. The shutter move to the TOP
in first stage, and move to the BOTTOM in second stage, and move to the TOP
again in third stage. Then PAN08 will know the total range of UP and DOWN.
4. During the shutter calibration process, any emergencies happen you can press
and release the include button to stop the process
5. If user found the direction is reverse, this may because the wrong connection of
NC and NO to the motor, please change NC and NO connection and execute
calibration process again.
3
6. To manually switch up and down of the shutter, simply press S1 or S2 .
7. PAN08 built in meter function and can read the Watt , KWh, V(Voltage),
I(Current) , PF(Power Factor) of the load by using Z-Wave command class, user
can set a threshold watt to get the warning caused by abnormal operation
8. PAN08 have overload protection function, and can help to prevent short circuit
caused by load.
Programming
1. Basic Command Class
The PAN08 will respond to BASIC and BINARY commands that are part of the
Z-Wave system.
1.1 BASIC_GET
When PAN08 receive Basic Set Command,it will send Basic Report Command
to report the position of the curtain。 When the report value is 0x00, that mean the
Shutter is bottom down, if the report value is 0xFF or 0x63 that mean the Shutter
is at the top, any other value between0x01~0x62 imply Shutter at 1%~99%
position;But if report value is 0xFE means the position is unknown
Basic Get Command: [Command Class Basic, Basic Get]
Basic Report Command
[Command Class Basic, Basic Report, Value = 0x00 (BOTTOM)]
[Command Class Basic, Basic Report, Value = 0x01~0x62 (Between BOT-
TOM and TOP)]
[Command Class Basic, Basic Report, Value = 0xFE (UNKNOWN)]
[Command Class Basic, Basic Report, Value = 0x63/0xFF (TOP)]
1-2 BASIC_SET
PAN08 can only accept Basic Set Command which value is either (0x00)Bottom or
Top (0x63/0xFF),other value is not acceptable
[Command Class Basic, Basic Set, Value = 0x63或0xFF] control the
shutter to the top (0xFF)
[Command Class Basic, Basic Set, Value = 0x00(0)] control the shutter to
the bottom(0x00)
2
Binary Switch Command Class