Philio Technology PAN06 User Manual

PAN06-1/-2/-3
In Wall Dual relay(1 way) switch module
P
Fig 1. Assembling
This in-wall switch module is a transceiver which is a Z-WaveTM enabled device and is fully compatible
with any Z-WaveTM enabled network. Mini size design let the module can easily hide itself into the wall
box and that will be good for the house decoration.
is the light control. If connect the com port directly to AC Line terminal ,the new smart relay calibration
technology can reduce the inrush current caused by the load and let the module work perfectly with many
kind of light like incandescent, fluorescent and LED light. This module can also connect to alternative
power supply like DC 12V to switch on/off 12V MR-16 light as follow picture.
Adding to Z-WaveTM Network
In the front casing, there is an on/off button with LED indicator below which is used to
toggle switch on and off or carries out inclusion, exclusion, reset or association.
When first power is applied, its LED flashes on and off alternately and repeatedly at
2-second intervals. It implies that it has not been assigned a node ID and cannot
work with Z-Wave enabled devices.
Auto Inclusion
The function of auto inclusion will be executed as long as the in wall switch does not
have Node ID and just connect the switch to main power.
Note: Auto inclusion timeout is 4 minute during which the node information of
explorer frame will be emitted once every 5 seconds. Unlike “inclusion” function as
shown in the table below, the execution of auto inclusion is free from pressing the
On/Off button on the Switch.
1
The table below lists an operation summary of basic Z-Wave functions. Please refer
to the instructions for your Z-WaveTM Certificated Primary Controller to access the
Setup function, and to include/exclude/associate devices
Function Description LED Indication
No node ID The Z-Wave Controller does not allocate
a node ID to the Switch.
2-second on, 2-second off
Inclusion 1. Have Z-Wave Controller entered
inclusion mode.
One press one flash
2. Pressing Include button of PAN06
three times within 1.5 seconds will
enter inclusion mode.
Exclusion 1. Have Z-Wave Controller entered
exclusion mode.
One press one flash
2. Pressing Include button of PAN06
three times within 1.5 seconds will
enter exclusion mode.
Node ID has been excluded. 2-second on, 2-second off
Reset 1. Pressing Include button of PAN06
three times within 1.5 seconds will
enter inclusion mode.
One press one flash
2. Within 1 second, press Include
button of PAN06 again for 5
seconds until LED is off.
3. IDs are excluded. 2-second on, 2-second off
Association 1. Have Z-Wave Controller entered
association mode.
Or Pressing Include button of PAN06
three times within 1.5 seconds will
enter association mode
One press one flash
2. There are 3 groups for the switch
Including a node ID allocated by Z-Wave Controller means inclusion. Excluding a node
ID allocated by Z-Wave Controller means exclusion.
Failed or success in including/excluding the node ID can be viewed from the Z-Wave
Controller.
Sometimes people are not easy to execute exclusion or inclusion especially when
PAN06 already installed in a wall box. To solve this issue, PAN06 support a special
feature that can use S1 or S2 to execute “exclusion, inclusion, Reset or Association”
at the first 3 minutes when first time connect to main power.
LED Indication
To distinguish what mode the switch is in, view from the LED for identification.
State Type LED Indication
Normal Whenever we switch On and off of the PAN06 by S1 S2 or On/Off
button or RF command , the LED will lights up 1 second and then
off.
No node ID Under normal operation, when the Switch has not been allocated a
node ID, the LED flashes on and off alternately at 2-second
intervals. By pressing S1 S2 or On/Off button, it will stop flashing
2
temporarily. However, after disconnect and reconnect the Switch,
the LED will flash on and off alternately at 2-second intervals.
Choosing a Suitable Location
1. Do not locate the Switch facing direct sunlight, humid or dusty place.
2. The suitable ambient temperature for the Switch is 0°C~40°C.
3. Do not locate the Switch where exists combustible substances or any source of
heat, e.g. fires, radiators, boiler etc.
4. After putting it into use, the body of Switch will become a little bit hot of which
phenomenon is normal.
Installation
1. Put the in wall switch into a wall box and connect the AC power wire L,N to
PAN06 connector L, N.
2. Connect the wall switch to the PAN06 as Fig1 .
3. There are 3 mode PAN06 can be configured to match different kind of wall
switch, please refer to 3-2 Edge / Pulse / Edge-Toggle mode which described
in next section of this user manual
4. If Edge-Toggle mode has been set, and the S1 S2 is connect to normal bi-stable
switch, every time when change the state of the wall switch will also swap the
state of Relay1 or Relay2
Programming
1. Basic Command Class / Binary Switch Command Class
The Switch will respond to BASIC and BINARY commands that are part of the Z-
Wave system.
1-1 BASIC_GET / BINARY_SWITCH_GET
Since the switch have two relay, the Switch will report its On/Off state to the
Controller by setting Configuration parameter 1.
Configuration parameter 1=1(default) Report ON either relay 1 ON or relay 2
ON