Philio Technology PAN05 User Manual

PAN05-1/-2/-3
In Wall Single relay(1 way) switch module
P
Fig 1. Assembling
This in-wall switch module is a transceiver which is a Z-WaveTM enabled device and
is fully compatible with any Z-WaveTM enabled network. Mini size design let the
module can easily hide itself into the wall box and that will be good for the house
There are many kind of application by using the module to switch Load On and Off ,
one main application is the light control. If connect the com port directly to AC Line
terminal ,the new smart relay calibration technology can reduce the inrush current
caused by the load and let the module work perfectly with many kind of light like
incandescent, fluorescent and LED light. This module can also connect to alternative
power supply like DC 12V to switch on/off 12V MR-16 light as follow picture.
Adding to Z-WaveTM Network
In the front casing, there is an on/off button with LED indicator below which is used to
toggle switch on and off or carries out inclusion, exclusion, reset or association. After
being excluded, its LED flashes on and off alternately and repeatedly at 2-second in-
tervals. It implies that it has not been assigned a node ID and cannot work with Z-
Wave enabled devices.
Auto Inclusion
The function of auto inclusion will be executed as long as the in wall switch does not
have Node ID and just connect the switch to main power.
Note: Auto inclusion timeout is 2 minute during which the node information of
explorer frame will be emitted once every 5 seconds. Unlike “inclusion” function as
1
shown in the table below, the execution of auto inclusion is free from pressing the
On/Off button on the Switch.
The table below lists an operation summary of basic Z-Wave functions. Please refer
to the instructions for your Z-WaveTM Certificated Primary Controller to access the
Setup function, and to include/exclude/associate devices
Function Description LED Indication
No node ID The Z-Wave Controller does not allocate
a node ID to the Switch.
2-second on, 2-second off
Inclusion 1. Have Z-Wave Controller entered
inclusion mode.
One press one flash
2. Pressing Include button of PAN05
three times within 2 seconds will
enter inclusion mode.
Exclusion 1. Have Z-Wave Controller entered
exclusion mode.
One press one flash
2. Pressing Include button of PAN05
three times within 2 seconds will
enter exclusion mode.
Node ID has been excluded. 2-second on, 2-second off
Reset 1. Pressing Include button of PAN05
three times within 2 seconds will
enter inclusion mode.
2. Within 1 second, press Include
button of PAN05 again for 5
seconds until LED is off.
3. IDs are excluded.
Association 1. Have Z-Wave Controller entered
association mode.
Or Pressing Include button of PAN05
three times within 2 seconds will
enter association mode
One press one flash
2. There are only 1 group for the switch
Including a node ID allocated by Z-Wave Controller means inclusion. Excluding a node
ID allocated by Z-Wave Controller means exclusion.
Failed or success in including/excluding the node ID can be viewed from the Z-Wave
Controller.
Sometimes people are not easy to execute exclusion or inclusion especially when
PAN05 already installed in a wall box. To solve this issue, PAN05 support a special
feature that can use S1 or S2 to execute “exclusion, inclusion, Reset or Association”
at the first 3 minutes when first time connect to main power.
LED Indication
To distinguish what mode the switch is in, view from the LED for identification.
State Type LED Indication
Normal Whenever we switch On and off of the PAN05 by S1 S2 or On/Off
button or RF command , the LED will lights up 1 second and then
2
off.
No node ID Under normal operation, when the Switch has not been allocated a
node ID, the LED flashes on and off alternately at 2-second
intervals. By pressing S1 S2 or On/Off button, it will stop flashing
temporarily. However, after disconnect and reconnect the Switch,
the LED will flash on and off alternately at 2-second intervals.
Learning When PAB01 is in learning mode, LED flashes on and off
alternately and repeatedly at 0.5 second intervals.
Choosing a Suitable Location
1. Do not locate the Switch facing direct sunlight, humid or dusty place.
2. The suitable ambient temperature for the Switch is 0°C~40°C.
3. Do not locate the Switch where exists combustible substances or any source of
heat, e.g. fires, radiators, boiler etc.
4. After putting it into use, the body of Switch will become a little bit hot of which
phenomenon is normal.
Installation
1. Put the in wall switch into a wall box and connect the AC power wire L,N to
PAN05 connector L, N.
2. Connect the wall switch to the PAN05 as Fig1 .
3. There are 3 mode PAN05 can be configured to match different kind of wall
switch, please refer to 3-1 Edge / Pulse / Edge-Toggle mode which described
in next section of this user manual.
4. If Edge-Toggle mode has been set, and the S1 S2 is connect to normal bi-stable
switch, every time when change the state of the wall switch will also swap the
state of Relay1.
Programming
1. Basic Command Class / Binary Switch Command Class
The Switch will respond to BASIC and BINARY commands that are part of the Z-