Philio Technology PAN04 User Manual

PAN04-1/-2/-3
In Wall Dual relay(1 way) switch module
P
Fig 1. Assembling
This in-wall dual relay switch module is a transceiver which is a Z-WaveTM enabled
device and is fully compatible with any Z-WaveTM enabled network. Mini size design
let the module can easily hide itself into the wall box and that will be good for the
There are many kind of application by using the module to switch AC power On and
Off , one main application is the light control. The new smart relay calibration
technology can reduce the inrush current caused by the load and let the module work
perfectly with many kind of light like incandescent, fluorescent and LED light.
This in-wall switch module is able to detect Instant power wattage (5~1500W) and
overload wattage (1600~1700W) of connected light or appliances. When detecting
overload state, the Module will be disabled and its On/Off button will be lockout of
which LED will flash quickly. However, disconnect and re-connect the Module will
reset its overload condition to normal status.
Adding to Z-WaveTM Network
In the front casing, there is an on/off button with LED indicator below which is used to
toggle switch on and off or carry out inclusion, exclusion, reset or association. When
first power is applied, its LED flashes on and off alternately and repeatedly at 2-
second intervals. It implies that it has not been assigned a node ID and cannot work
with Z-Wave enabled devices.
Auto Inclusion
The function of auto inclusion will be executed as long as the in wall switch does not
have Node ID and just connect the switch to main power.
Note: Auto inclusion timeout is 4 minute during which the node information of
explorer frame will be emitted once every 5 seconds. Unlike “inclusion” function as
1
shown in the table below, the execution of auto inclusion is free from pressing the
On/Off button on the Switch.
The table below lists an operation summary of basic Z-Wave functions. Please refer
to the instructions for your Z-WaveTM Certificated Primary Controller to access the
Setup function, and to include/exclude/associate devices
Function Description LED Indication
No node ID The Z-Wave Controller does not allocate
a node ID to the Switch.
2-second on, 2-second off
Inclusion 1. Have Z-Wave Controller entered
inclusion mode.
One press one flash
2. Pressing INCLUDE_BUTTON three
times within 1.5 seconds will enter
inclusion mode.
Exclusion 1. Have Z-Wave Controller entered
exclusion mode.
One press one flash
2.
Pressing INCLUDE_BUTTON three
times within 1.5 seconds will enter
exclusion mode.
Node ID has been excluded. 2-second on, 2-second off
Reset 1. Pressing INCLUDE_BUTTON three
times within 1.5 seconds will enter
inclusion mode.
One press one flash
2. Within 1 second, press On/Off
button again for 5 seconds until LED
is off.
3. IDs are excluded. 2-second on, 2-second off
Association
1.
Have Z-Wave Controller entered
association mode.
Or Pressing INCLUDE_BUTTON three
times within 1.5 seconds will enter
association mode
One press one flash
2. There are 3 groups for the switch
Including a node ID allocated by Z-Wave Controller means inclusion. Excluding a node
ID allocated by Z-Wave Controller means exclusion.
Failed or success in including/excluding the node ID can be viewed from the Z-Wave
Controller.
LED Indication
To distinguish what mode the switch is in, view from the LED for identification.
State Type LED Indication
Normal Whatever we switch On and off of the PAN04 by S1 S2 or On/Off
button or RF command , the LED will lights up 1 second and then
off.
No node ID Under normal operation, when the Switch has not been allocated a
2
node ID, the LED flashes on and off alternately at 2-second
intervals. By pressing S1 S2 or On/Off button, it will stop flashing
temporarily. However, after disconnect and reconnect the Switch,
the LED will flash on and off alternately at 2-second intervals.
Overload When overload state occurs, the Switch is disabled of which LED
flashes on and off alternately at 0.5 second intervals. Overload
state can be cleared by disconnect and reconnect the Switch to
the main power
Choosing a Suitable Location
1. Do not locate the Switch facing direct sunlight, humid or dusty place.
2. The suitable ambient temperature for the Switch is 0°C~40°C.
3. Do not locate the Switch where exists combustible substances or any source of
heat, e.g. fires, radiators, boiler etc.
4. After putting it into use, the body of Switch will become a little bit hot of which
phenomenon is normal.
Installation
1. put the in wall switch into a wall box and connect the AC power wire L,N to
PAN04 connector L, N.
2. Connect the wall switch to the PAN04 as Fig1 .
3. To manually turn ON the Switch, press and release the On/Off button. The LED
will light ON for 1 second, and the load plugged into the Switch will also turn ON.
4. To manually turn OFF the Switch, simply press and release the On/Off button.
The LED will light ON for 1 second and the load plugged into the Switch will turn
3
OFF.
Programming
1. Basic Command Class / Binary Switch Command Class
The Switch will respond to BASIC and BINARY commands that are part of the Z-
Wave system.
1-1 BASIC_GET / BINARY_SWITCH_GET
Since the switch have two relay, the Switch will report its On/Off state to the
Controller by setting Configuration parameter 3.
Configuration parameter 3=1(default) Report ON either relay 1 ON or relay 2
ON
Report OFF when both relay 1 and relay 2 OFF
Configuration parameter 3=2 Report ON when relay 1 ON
Report OFF when relay 1 OFF
Configuration parameter 3=3 Report ON when relay 2 ON
Report OFF when relay 2 OFF
Basic Get Command: [Command Class Basic, Basic Get]
Basic Report Command:
Report OFF: [Command Class Basic, Basic Report, Value = 0(0x00)]
Report ON:[Command Class Basic, Basic Report, Value = (255)0xFF]
Binary Switch Get Command:[Command Class Switch Binary, Switch
Binary Get]
Binary Switch Report Command:
Report OFF:[Command Class Switch Binary, Switch Binary Report, Value
=0(0x00)]
Report ON:[Command Class Switch Binary, Switch Binary Report, Value =
(255)0xFF]
1-2 BASIC_SET / SWITCH_BINARY_SET
Since the switch have two relay, the load attached to the Switch will turn on or
off upon receipt of the following commands from a Z-Wave Controller by setting
Configuration parameter 3.
Configuration parameter 3=1(default) switch ON and OFF both relay 1 and
relay 2
Configuration parameter 3=2 switch ON and OFF of relay 1
Configuration parameter 3=3 switch ON and OFF of relay 2
,
[Command Class Basic, Basic Set, Value = (255)0xFF]: the load attached to
4
the Switch turns on.
[Command Class Basic, Basic Set, Value = 0(0x00)]: the load attached to
the Switch turns off.
[Command Class Switch Binary, Switch Binary Set, Value = (255)0xFF]:
the load attached to the Switch turns on.
[Command Class Switch Binary, Switch Binary Set, Value = 0(0x00)]: the
load attached to the Switch turns off.
2. Z-Wave’s Groups (Association Command Class Version 1)
The Switch can be set to send reports to control associated Z-Wave devices. It
supports 3 association groups which every group has one node support.
Group1~Group3 support SWITCH_BINARY_REPORT,
METER_REPORT_COMMAND_V3
For group 1, the Switch will report (1) ON/OFF status of Relay1 and Relay2 (2)
Instant Power Consumption (Watt) of Relay1 and Relay2 (3) Accumulated Power
Consumption (KWh) of Relay1 and Relay2 to Z-Wave Controller.
For group 2, the Switch will report (1) ON/OFF status of Relay1 (2) Instant Power
Consumption (Watt) of Relay1 (3) Accumulated Power Consumption (KWh) of Relay1
to Z-Wave Controller.
For group 3, the Switch will report (1) ON/OFF status of Relay2 (2) Instant Power
Consumption (Watt) of Relay2 (3) Accumulated Power Consumption (KWh) of Relay2
to Z-Wave Controller.
2-1 Auto report to Grouping 1 ~3(Maximum Node 1)
2-1-1 On/Off Event Report
When “on” or “off ” state has been changed by pressing S1 S2 or on/off button, it
will send Binary Switch Report to the nodes of Group1~3. But if “on” or “off ” state
has been changed by RF command (ex. Switch Binary set、 All Switch ON/OFF or
Basic Set), it will not send.
Binary Switch Report
ON:[Command Class Switch Binary, Switch Binary Report, Value
=(255)0xFF]
OFF:[Command Class Switch Binary, Switch Binary Report, Value
=0(0x00)]
2-1-2 Instant Power Consumption vary over 5% report
When the power consumption of load vary over 5%, it will send Meter report to the
nodes of Group
5
Meter Value
Meter Report Command: [Command Class MeterMeter Reportscale(bit 2) +Rate Type +Meter TypePrecision + Scale(bit 1,0)+ SizeMeter Value 1Meter Value 2Meter Value 3
2-1-3 overload alarm report command
When PAN04 detect the overload , it will send Alarm Report to the correspond
Group
The content of Alarm Report
2-2 Response to Meter Get Command
The Switch will report its (1) instant Power Consumption (Watt) or (2) accumulated
power consumption(KWH) or (3) AC load Voltage (V) or (4) AC load current ( I )
(5) load power factor (PF) to Z-Wave Controller after receive the Meter Get
Command from Z-Wave Controller.
2-2-1 Instant Power Consumption (Watt) of Switch
When receiving Meter Get Command, it will report Meter Report Command to the
node asked.
Meter Get Command: [Command Class Meter, Meter Get, Scale =0x02(W)]
Meter Report Command: [Command Class Meter,Meter Report,scale(bit
2) +Rate Type +Meter Type,Precision + Scale(bit 1,0)+ Size,Meter
Value 1,Meter Value 2,Meter Value 3,Meter Value 4]
Rate Type = 0x01
Meter Type = 0x01
Precision = 1
Scale = 0x02(W)
Size = 4 Bytes (Meter Value)
Meter Value 1 = (W) MSB
Meter Value 2 = (W)
Meter Value 3 = (W)
Meter Value 4 = (W)LSB
Example:
Meter Value 1 = 0x00 (W)
Meter Value 2 = 0x00 (W)
Meter Value 3 = 0x03 (W)
Meter Value 4 = 0xEA (W)
Meter(W) = Meter Value 3 *256 + Meter Value 4 = 100.2W
2-2-2 Accumulated Power Consumption (KW/h)
When receiving Meter Get Command, it will report Meter Report Command to
6
Alarm report command: [Command_Class_Alarm, Alarm_Report, Alarm Type = 0x08, Alarm Level = 0xFF]