Philio Technology PAN03 User Manual

PAN03-1/-2/-3
Smart Energy In wall Switch Module
P
Fig 1. Assembling
This in-wall dual relay switch module is a transceiver which is a Z-WaveTM enabled
device and is fully compatible with any Z-WaveTM enabled network. Mini size design
let the module can easily hide itself into the wall box and that will be good for the
There are many kind of application by using the module to switch AC power On and
Off , one main application is the light control. The new smart relay calibration
technology can reduce the inrush current caused by the load and let the module work
perfectly with many kind of light like incandescent, fluorescent and LED light.
This in-wall switch module is able to detect Instant power c (5~2500W)(11Ampere)
and overload wattage (2700~2800W)(12 Ampere) of connected light or appliances.
When detecting overload state, the Module will be disabled and its On/Off button will
be lockout of which LED will flash quickly. However, disconnect and re-connect the
Module will reset its overload condition to normal status.
Adding to Z-WaveTM Network
In the front casing, there is an on/off button with LED indicator below which is used to
toggle switch on and off or carry out inclusion, exclusion, reset or association. When
first power is applied, its LED flashes on and off alternately and repeatedly at 2-
second intervals. It implies that it has not been assigned a node ID and cannot work
with Z-Wave enabled devices.
Auto Inclusion
The function of auto inclusion will be executed as long as the in wall switch does not
have Node ID and just connect the switch to main power.
1
Note: Auto inclusion timeout is 4 minute during which the node information of
explorer frame will be emitted once every 5 seconds. Unlike “inclusion” function as
shown in the table below, the execution of auto inclusion is free from pressing the
On/Off button on the Switch.
The table below lists an operation summary of basic Z-Wave functions. Please refer
to the instructions for your Z-WaveTM Certificated Primary Controller to access the
Setup function, and to include/exclude/associate devices
Function Description LED Indication
No node ID The Z-Wave Controller does not allocate
a node ID to the Switch.
2-second on, 2-second off
Inclusion 1. Have Z-Wave Controller entered
inclusion mode.
One press one flash
2. Pressing INCLUDE_BUTTON three
times within 1.5 seconds will enter
inclusion mode.
Exclusion 1. Have Z-Wave Controller entered
exclusion mode.
One press one flash
2.
Pressing INCLUDE_BUTTON three
times within 1.5 seconds will enter
exclusion mode.
Node ID has been excluded. 2-second on, 2-second off
Reset 1. Pressing INCLUDE_BUTTON three
times within 1.5 seconds will enter
inclusion mode.
One press one flash
2. Within 1 second, press On/Off
button again for 5 seconds until LED
is off.
3. IDs are excluded. 2-second on, 2-second off
Association
1.
Have Z-Wave Controller entered
association mode.
Or Pressing INCLUDE_BUTTON three
times within 1.5 seconds will enter
association mode
One press one flash
2. There are 3 groups for the switch
Including a node ID allocated by Z-Wave Controller means inclusion. Excluding a node
ID allocated by Z-Wave Controller means exclusion.
Failed or success in including/excluding the node ID can be viewed from the Z-Wave
Controller.
LED Indication
To distinguish what mode the switch is in, view from the LED for identification.
State Type LED Indication
Normal Whatever we switch On and off of the PAN03 by S1 S2 or On/Off
2
button or RF command , the LED will lights up 1 second and then
off.
No node ID Under normal operation, when the Switch has not been allocated a
node ID, the LED flashes on and off alternately at 2-second
intervals. By pressing S1 S2 or On/Off button, it will stop flashing
temporarily. However, after disconnect and reconnect the Switch,
the LED will flash on and off alternately at 2-second intervals.
Overload When overload state occurs, the Switch is disabled of which LED
flashes on and off alternately at 0.5 second intervals. Overload
state can be cleared by disconnect and reconnect the Switch to
the main power
Choosing a Suitable Location
1. Do not locate the Switch facing direct sunlight, humid or dusty place.
2. The suitable ambient temperature for the Switch is 0°C~40°C.
3. Do not locate the Switch where exists combustible substances or any source of
heat, e.g. fires, radiators, boiler etc.
4. After putting it into use, the body of Switch will become a little bit hot of which
phenomenon is normal.
Installation
1. put the in wall switch into a wall box and connect the AC power wire L,N to
PAN03 connector L, N.
2. Connect the wall switch to the PAN03 as Fig1 .
3. To manually turn ON the Switch, press and release the On/Off button. The LED
will light ON for 1 second, and the load plugged into the Switch will also turn ON.
3