Philio Technology PAD07 User Manual

PAD07 In Wall Smart Dimmer
Warning: Do not use Non-Dimmable LED lamps.
Fig 1. Assembling & Wiring
Built-in High Breaking Capacity current fuse protection. Rating : 2A /250V.
Built-in Thermal Cutoff Fuses protection. Rated Temperature :125 °C; Rating :
2A /250V.
Wave Plus
TM
enabled devices displaying the Z-Wave Plus
TM
logo can also be used
with it regardless of the manufacturer, and can also be used in other manufacturer’s
Z-Wave
TM
enabled networks. You can On/Off the light by pressing the button briefly,
or a long pressing to control the brightness of dimmable light bulb.
This dimmer is a transceiver which is a security enabled device which based on
Z-Wave Plus technology, and it is fully compatible with any Z-Wave
TM
enabled
network. Since PAD07 supports Security Command Class, it can learn with
Secured controller. Its functionality and supported command classes is identical
when included as a secure and non-secure device.
Adding to Z-Wave
TM
Network
In the front casing, there is an on/off button (also an include button) with LED indica-
tor below which is used to dim on and off or carries out inclusion, exclusion, reset or
association. When first power applied, its LED flashes on and off alternately and re-
peatedly at 0.5 second intervals. It implies that it has not been assigned a node ID
and start auto inclusion.
Auto Inclusion
The function of auto inclusion will be executed as long as the dimmer does not
have Node ID and just connect the switch to main power.
Note: Auto inclusion timeout is 2 minute during which the node information of
explorer frame will be emitted once every several seconds. Unlike “inclusion” function
as shown in the table below, the execution of auto inclusion is free from pressing the
1
On/Off button on the dimmer.
The table below lists an operation summary of basic Z-Wave functions. Please refer
to the instructions for your Z-Wave
TM
Certificated Primary Controller to access the
Setup function, and to Add/Remove/associate devices
Function Description Annotation
No node ID The Z-Wave Controller does not allocate
a node ID to the Switch.
LED 2-second on, 2-second
off
Add (Inclusion) 1. Put your Z-Wave controller into
inclusion mode by following the
instructions provided by the
controller manufacturer.
2. Pressing Include button of PAD07
three times within 2 seconds will
enter inclusion mode.
Remove
(Exclusion)
1. Put your Z-Wave controller into
exclusion mode by following the
instructions provided by the
controller manufacturer.
2. Pressing Include button of PAD07
three times within 2 seconds will
enter exclusion mode.
3. Node ID has been excluded. 0.5s On, 0.5s Off (Enter
auto inclusion)
Reset 1. Pressing Include button of PAD07
three times within 2 seconds will
enter inclusion mode.
Use this procedure only in
the event that the primary
controller is lost or
otherwise inoperable.
2. Within 1 second, press Include button
of PAD07 again for 5 seconds.
3. IDs are excluded. 0.5s On, 0.5s Off (Enter
auto inclusion)
Association 1. The PAD07 is an always listening
Z-Wave device, so associations
may be added or removed by a con-
troller at any time.
Or If your controller requires to have
the PAD07 send a 'node information
frame' or NIF for associations, then
pressing the On/Off button three
times within 2 seconds will cause
the PAD07 to send its NIF.
2. There is only one group for the
dimmer
Adding a node ID allocated by Z-Wave Controller means inclusion. Removing a node
ID allocated by Z-Wave Controller means exclusion.
Failed or success in including/excluding the node ID can be viewed from the Z-Wave
Controller.
LED Indication
2
To distinguish what mode the switch is in, view from the LED for identification.
State Type LED Indication
Normal Whenever we switch On and off of the PAD07 by On/Off button or RF
command, the LED will lights up when switch on; whereas LED off
when switch off.
No node ID Under normal operation, when the Switch has not been allocated a
node ID, the LED flashes on and off alternately at 2-second intervals.
By pressing On/Off button, it will stop flashing temporarily.
Learning When PAD07 is in learning mode, LED flashes on and off alternately
and repeatedly at 0.5 second intervals.
Choosing a Suitable Location
1. Do not locate the dimmer facing direct sunlight, humid or dusty place.
2. The suitable ambient temperature for the Switch is 0°C~40°C.
3. Do not locate the dimmer where exists combustible substances or any source of
heat, e.g. fires, radiators, boiler etc.
4. After putting it into use, the body of dimmer will become a little bit hot of which
phenomenon is normal.
Manual dim level control :
To manually switch on the light, press and release the On/Off button or S1/S2 shortly
when the light is off. The light will dim from off to the level which was set before
switch off. To manually switch off the light, press and release the On/Off button or
S1/S2 shortly when the light is on. To adjust the dim level, press and hold the On/Off
button or S1/S2 until the desired dim level is achieved, then release.
Programming
1. Basic Command Class / Multilevel Switch Command Class
The dimmer will respond to BASIC and MULTILEVEL SWITCH commands that are
part of the Z-Wave system. If PAD07 is included as a secured node, it will only re-
sponse to the security encapsulation command of BASIC and MULTILEVEL
SWITCH.
1-1 BASIC_GET / MULTILEVEL_SWITCH_GET
Upon receipt of the following commands from a Z-Wave Controller, the Switch will
report its dimmer state to the node inquired.
Basic Get Command: [Command Class Basic, Basic Get]
Basic Report Command:
Report OFF: [Command Class Basic, Basic Report, Value = 0]
Report ON:[Command Class Basic, Basic Report, Value = 1~99]
Multilevel Switch Get Command:[Command Class Multilevel Switch, Multilevel
Switch Get]
Multilevel Switch Report Command:
Report OFF:[Command Class Multilevel Switch, Multilevel Switch Report,
Value=0]
Report ON:[Command Class Multilevel Switch, Multilevel Switch Report, Value
=1~99]
3