P R O D U C T S E X S I G N A L I N G D E V I C E S
FLASHING LIGHT 5 J
CWB-ATEX
The flashing lights from the CWB-ATEX series are explosion-protected equipment and serve as visual alarms in potentially explosive workplaces in Zones 1, 2, 21 and 22.
• Housing made of aluminium, therefore usable in all chemical and petrochemical plants as well as offshore plants.
• High protection system and stable mechanical construction allow use under the toughest operating conditions.
• Various mounting brackets and a protective cage are available as accessories.
IP 66 |
+50 °C |
||
|
|
||
–40 °C |
|||
|
|||
protection |
operating |
||
system |
temperature |
PRODUCT |
|
|
|
|
|
CWB-ATEX |
|
|
|||
Rated voltage |
|
|
230 V |
110–127 V |
|
24–42 V |
|
60–80 V |
|
12–48 V |
24 V |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
AC 50 | 60 Hz |
|
|
|
DC |
|
|||
|
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
Operating range |
|
|
|
|
|
|
±10 % |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
Nominal current consumption |
0.08 A |
0.11 A |
|
0.5–0.3 A |
|
0.11–0.13 A |
|
0.5–0.3 A |
0.4 A |
||
|
|
|
|
|
|
|
|
|
|
|
|
Type of protection |
|
|
|
|
“d” flame proof enclosure for light housing |
|
|
||||
|
|
|
|
|
“e” enhanced safety for terminal box |
|
|
||||
|
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
II 2 G Ex d e IIC T6 Gb |
|
|
|||
Explosion protection |
|
|
|
|
|
II 2 G Ex d e IIC T5 Gb |
|
|
|||
|
|
|
|
|
II 2 D Ex tb IIIC T85°C Db IP66 (T6) |
|
|
||||
|
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
II 2 D Ex tb IIIC T100°C Db IP66 (T5) |
|
|
|||
Category (area of use) |
|
|
|
|
|
2G (Zone 1) / 3G (Zone 2) |
|
|
|||
|
|
|
|
|
2D (Zone 21) / 3D (Zone 22) |
|
|
||||
|
|
|
|
|
|
|
|
||||
Certificate of conformity |
|
|
|
LCIE 02 ATEX 6113 |
|
|
|||||
|
|
|
|
|
|
|
|
|
|
||
Testing body |
|
|
|
|
|
|
LCIE |
|
|
||
|
|
|
|
|
|
|
|
|
|
||
Flash energy |
|
|
|
|
|
|
5 J |
|
|
||
|
|
|
|
|
|
|
|
|
|||
Flash rate |
|
|
|
|
|
approx. 1 Hz |
|
|
|||
|
|
|
|
|
|
|
|
|
|||
Temperature class |
|
T6 |
|
|
|
Tamb: –40 °C ... +40 °C |
|
|
|||
|
T5 |
|
|
|
Tamb: –40 °C ... +50 °C |
|
|
||||
|
|
|
|
|
|
|
|||||
Storage temperature |
|
|
|
|
|
–20 °C ... +80 °C |
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
Relative humidity |
|
|
|
|
|
|
90 % |
|
|
|
|
|
|
|
|
|
|
||||||
Protection system (EN 60529) |
|
|
IP 66 (when used for design purpose) |
|
|
||||||
|
|
|
|
|
|
|
|
|
|
|
|
Duty cycle |
|
|
|
|
|
|
100 % |
|
|
|
|
|
|
|
|
||||||||
Service life of the light source |
|
light emission still 70 % after 8,000,000 flashes |
|
||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
lens |
|
|
|
|
|
polycarbonate (PC) |
|
|
|
Material |
|
|
|
|
|
|
|
||||
protective cage |
|
|
|
stainless steel |
|
|
|||||
|
|
|
|
|
|
|
|
||||
|
housing |
|
|
|
aluminium alloy yellow; plinth black |
|
|
||||
|
|
|
|
|
|
|
|
|
|||
Type of connection |
|
|
|
|
|
screw terminals |
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
terminal area |
|
(max.) 2x 4 mm2 (single wire), 2x 2.5 mm2 (fine wire) |
|
||||||||
|
|
|
|||||||||
Cable entry |
|
|
|
1x cable gland M20 x 1.5, chrome-plated, clamping range 6–13 mm |
|
||||||
|
|
|
|
|
1x blanking plug, M20 x 1.5 |
|
|
||||
|
|
|
|
|
|
|
|
||||
Weight |
|
|
|
|
|
approx. 1.24 kg |
|
|
DIMENSIONS
Ø 82
<![if ! IE]> <![endif]>282 |
Ø 70 |
<![if ! IE]> <![endif]>260 |
|
|
91
Mounting plate
130
4
<![if ! IE]> <![endif]>25 |
<![if ! IE]> <![endif]>7 |
<![if ! IE]> <![endif]>50 |
7
110
Direct mounting to wall/fl oor |
Standard bracket |
thread depth 8 mm (M6)
M6 x |
|
32 |
<![if ! IE]> <![endif]>35 |
|
10 mm |
|
|
|
|
deep |
|
|
|
<![if ! IE]> <![endif]>80 |
32 |
|
|
<![if ! IE]> <![endif]>35 |
|
|
|
|
Ø 7 |
|
X |
|
91 |
35 |
|
|
|
|
||
|
|
50 |
|
|
|
|
|
|
|
Pipe clamp |
|
|
Mounting bracket |
|
11/4" (Ø 42) |
|
|
135 |
|
11/2" (Ø 48) |
|
|
15° |
|
|
|
|
|
|
2" (Ø 60) |
|
15 |
|
|
|
|
|
|
|
|
40 |
8.5 |
<![if ! IE]> <![endif]>110 |
|
|
|
R66 |
||
|
|
|
||
|
|
|
|
|
11/4" – 76 |
|
<![if ! IE]> <![endif]>70 8.5 |
|
|
11/2" – 77 |
|
<![if ! IE]> <![endif]>10 |
|
|
2" – 90 |
|
|
||
|
|
|
|
|
|
|
34 |
23 |
|
ARTICLE NO. |
|
|
|
|
|
|
|
|
|
|
|
CWB-ATEX |
|
|
||||
Lens colour |
|
|
|
|
230 V AC |
|
|
|
110–127 V AC |
|
60–80 V DC |
24–42 V AC / 12–48 V DC |
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
31006103000 |
|
|
31006133000 |
|
|
31006583000 |
31006903000 |
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
31006104000 |
|
|
31006134000 |
|
|
31006584000 |
31006904000 |
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
31006105000 |
|
|
31006135000 |
|
|
31006585000 |
31006905000 |
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Artikelnummern weiterer Farben auf Anfrage. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
OPTIONS/ACCESSORIES |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Pipe |
|
|
Mounting |
|
|
|
Mounting |
|
|
Standard |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
bracket |
|
|
|
|
|
|
|
|||||
clamps |
|
bracket |
|
|
|
plate |
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
set |
|
|
|
|
|
|
|
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
Stainless steel |
Stainless steel |
Stainless steel |
Stainless steel |
Stainless steel |
|
|
||||||||||||
Article no.: |
Article no.: |
Article no.: |
Article no.: |
Article no.: |
|
|
||||||||||||
R1 1/4": 38108101000 |
38108100100 |
|
38108100000 |
38108100150 |
38108100200 |
|
|
|
||||||||||
R1 1/2": 38108101200 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
R2": |
38108102000 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
MANUFACTURER’S DECLARATION
We hereby declare that the explosion-protected flashing light with the type designation Ex-CWB-ATEX has been developed and manufactured in accordance with the requirements as per EN 60079-0.
This declaration is based on compliance with the following regulations and standards:
EN 60079-0 |
Electrical equipment for areas at risk of explosions – |
EN 60079-1 |
Pressure-resistant encapsulation “d” |
|
General requirements |
EN 60079-7 |
Enhanced safety “e” |
EN 61241-0 |
Electrical equipment for use in areas with combustible dust |
EN 60598 |
Lights |
EN 60400 / IEC 61 Lamp sockets for tube-shaped fluorescent lamps and starter sockets |
EN 60529 |
Types of protection by enclosure (IP code) |
|
94/9/EG |
CE conformity |
2004/108/EG |
“Electromagnetic compatibility” |
The flashing light is approved for use in potentially explosive areas in Zones 1, 2, 21 and 22 as per 94/9/EU.
<![endif]>EX SIGNALING DEVICES